Fundamentals / Physics / Electrodynamics / Electrostatic field theory and measurement

Cylindrical geometry, coaxial boundaries and Bessel spectra

The radial coordinate of a cylinder leads to logarithms in one experiment and to Bessel functions in another. The difference is set by the variation along the axis and around the circumference. Recovering the radial weight from flux clarifies both.

A conducting annulus selects a logarithmic radial potential

Put a long cylindrical metal electrode of radius \(a\) inside a coaxial grounded tube of radius \(b\), with homogeneous dielectric of permittivity \(\epsilon\) in the gap. Long means that probes are far enough from both ends for axial variation to be negligible. With no free gap charge and no angular variation, Laplace's equation reduces to \(\partial_r(r\partial_r V)=0\). One integration gives \(rV'=C\), a statement of conserved radial flux through cylinders; the second gives a logarithm. With inner electrode at \(V_0\),

\[V(r)=V_0\frac{\ln(b/r)}{\ln(b/a)},\]
\[E_r=\frac{V_0}{r\ln(b/a)},\]
\[C'=\frac{2\pi\epsilon}{\ln(b/a)} .\]

Here \(C'\) is capacitance per length. To obtain it, integrate \(D_r\) over the inner metal face per unit axial length and divide by \(V_0\). Another route integrates the energy density \(\epsilon E_r^2/2\) times \(2\pi r\,dr\), giving \(C'V_0^2/2\). For \(a=2\) mm, \(b=8\) mm and \(\epsilon=2\epsilon_0\), \(C'=80.3\) pF/m. At \(r=\sqrt{ab}=4\) mm the voltage is \(V_0/2\); the half-voltage radius is the geometric mean. An equally spaced radial ruler does not sample equal voltage steps.

The logarithm is not allowed at the axis of a solid charge-free cylinder because it diverges and carries line-source flux. In the annular domain the singular axis is outside the field region. The same radial function can therefore be admissible or inadmissible in two problems with very similar geometry. Before discarding a mathematical solution, check which radii actually lie in the domain and whether singular sources were explicitly prescribed.

Nonuniform wall voltages in a two-dimensional disk

Next take a full disk of radius \(a\) with prescribed side voltage \(f(\phi)\), invariant in \(z\). Seek \(R(r)e^{im\phi}\). Single-valuedness after \(\phi\to\phi+2\pi\) forces integer \(m\). The radial equation \(r^2R''+rR'-m^2R=0\) is solved by \(r^{|m|}\) and \(r^{-|m|}\) for \(m\ne0\); regularity at the centre chooses the growing power. The zero mode is constant, discarding its logarithmic partner. Thus an angular Fourier component on the wall penetrates as \((r/a)^{|m|}\). At \(r=a/2\), a third harmonic retains one eighth while a sixth harmonic retains only one sixty-fourth. Both can coexist on the wall without being equally visible in the interior.

For \(f(\phi)=2+3\cos(2\phi)\) V, the interior is

\[2+3(r/a)^2\cos(2\phi)=2+3(x^2-y^2)/a^2.\]

The potential has a saddle at the centre, with zero field there and opposite Cartesian curvatures. A scan along a single diameter could show a conspicuous maximum without detecting any charge. The two-dimensional Laplacian is zero because the curvatures cancel. This is also a useful finite-difference benchmark: a centred Cartesian Laplacian differentiates this quadratic exactly in the interior when the circular boundary has been represented correctly.

End effects produce a Sturm–Liouville problem

Now ground the side of a circular tube, excite its end at \(z=0\) and look for fields decaying into \(z>0\). For an axisymmetric source-free potential \(V=R(r)Z(z)\), choose \(Z=e^{-kz}\) for decay. Laplace's equation becomes

\[(rR')'+k^2rR=0.\]

The solutions are \(J_0(kr)\) and \(Y_0(kr)\). The former is regular with value one at zero; the latter diverges logarithmically. Grounding at \(r=a\) requires \(J_0(ka)=0\), so \(k_n=j_n/a\) with positive roots \(j_1=2.40483,\ j_2=5.52008,\ldots\). Unlike sine wavenumbers they are not evenly spaced at low index.

Multiplying two such eigen-equations by the opposite radial function, subtracting and integrating gives \((k_m^2-k_n^2)\int rR_mR_n\,dr\) equal to the endpoint term \(r(R_n'R_m-R_m'R_n)\). It vanishes at a grounded wall and at a smooth axis. Hence modes at distinct eigenvalues are orthogonal with weight \(r\). This weight arises physically from the circumference of a radial ring. Normalize dimensionless radius \(x=r/a\). For a zero \(j_n\), the squared modal norm is \(J_1(j_n)^2/2\). An end profile \(f(x)\) therefore gives

\[V(r,z)=\sum_n c_n J_0(j_n r/a)e^{-j_n z/a},\]
\[c_n=\frac{2}{J_1(j_n)^2}\int_0^1 x f(x)J_0(j_n x)\,dx .\]

For \(f=V_0\) across the cap, \(\int_0^1xJ_0(jx)dx=J_1(j)/j\) by differentiating \(xJ_1(jx)\). Then \(c_n=2V_0/[j_nJ_1(j_n)]\), with alternating signs. The cap voltage jumps at the wall corner, making its near-rim reconstruction slow. A smooth end pattern that already vanishes at \(a\) yields faster coefficient decay. In either case a narrow radial strip at the axis should not be given as much integration weight as an equal width near the circumference.

Two ways to see which axial scale survives

Far enough from the cap the first excited nonzero coefficient dominates. Its length is

\[a/j_1=0.416a.\]

Ratios of distant on-axis voltages can then identify tube radius without absolute calibration of the cap voltage. For \(a=15.0\) mm, an added 5.0 mm of distance should give factor \(e^{-2.40483/3}=0.449\). Repeat this estimate at several starting positions. The ratio only approaches that value once competing modes have decayed. A datum deep enough to suppress all higher modes may also be close to the instrument noise level, which biases a fitted decay length.

Instead impose an axial sinusoid \(e^{ikz}\) on a very long cylinder's side wall. The radial equation now has the opposite sign, \((rR')'-k^2rR=0\), whose regular solution is the modified Bessel function \(I_0(kr)\). The potential is \(V_0 I_0(kr)\cos(kz)/I_0(ka)\). The experiment selects a real oscillation along \(z\), not an exponential attenuation away from an end. Near the axis \(I_0(\xi)=1+\xi^2/4+\cdots\); the field generated by a long-wavelength side modulation is nearly uniform across a narrow cross section. At large \(ka\), \(I_0(ka)\) grows exponentially and the axis scarcely senses a short-wavelength wall pattern. Calling every radial solution simply a Bessel mode without tracking the separation sign can exchange these two physical predictions.

Construct a grid that treats the axis as a regular point

A conservative radial discretisation starts from \(\int_{r_-}^{r_+}r\,\nabla_r^2V\,dr=[rV']_{r_-}^{r_+}\). Use annular cells and fluxes at shared ring faces. Near \(r=0\) the left face has zero circumference, requiring no unknown point beyond the axis. For a nodal grid with Taylor expansion \(V(r)=V(0)+Ar^2+O(r^4)\), the radial operator at zero is \(4A\), so \(\nabla_r^2V(0)\simeq4[V(h)-V(0)]/h^2\). Simply setting \(1/r=0\) and using the Cartesian one-dimensional second derivative misses a factor of two.

Compare a numerical response to the analytic \(J_0\) mode at a fixed \(z/a\). Test the wall value, axis derivative, radial energy norm and distant decay rate. These are independent observables. A discretisation can reproduce the slowest length while misrepresenting an edge profile composed of many faster modes. Conversely, matching a discontinuous cap perfectly at mesh nodes does not demonstrate that high-order interior amplitudes are accurate.

Can a coaxial dielectric be graded to produce a uniform field?

The homogeneous coaxial field grows as \(1/r\) and reaches its highest magnitude at the inner wire. A designer proposes grading the dielectric radially so the full annular gap experiences one common radial field. Assume both metal faces are equipotentials, the scalar permittivity \(\epsilon(r)\) may vary continuously, and there is no free volume charge. Cylindrical symmetry still gives \(D_r=\lambda/(2\pi r)\), independent of how the material is graded. A constant electric-field magnitude \(E_g\) requires \(\epsilon(r)=\lambda/(2\pi E_g r)\), that is, permittivity proportional to \(1/r\). This construction replaces a uniform material by a known spatial distribution; applying \(\epsilon(r)\nabla^2V=0\) would miss the material gradient and give the wrong field.

Write \(\epsilon(r)=\epsilon_a a/r\). At applied voltage \(V_0\), the constant field is \(E_g=V_0/(b-a)\), and charge per length is

\[\lambda=2\pi\epsilon_a a V_0/(b-a).\]

Thus \(C'=2\pi\epsilon_a a/(b-a)\). For \(a=2.0\) mm, \(b=6.0\) mm, \(\epsilon_a=6\epsilon_0\), the outer relative permittivity is 2, and \(C'=167\) pF/m. At 12 V every radius experiences \(3000\) V/m. For a homogeneous dielectric at the same voltage the inner surface field would be \(12/[0.002\ln3]=5461\) V/m regardless of its constant permittivity. The gradient reduces peak field at fixed voltage. Whether a real material benefits also depends on its local field limit, losses and interfaces.

Where is the polarisation charge that makes this possible? In the dielectric the true total charge satisfies

\[\rho_{\rm tot}=\epsilon_0\nabla\cdot\mathbf E=\epsilon_0E_g/r.\]

All of it is bound since \(\rho_f=0\). Direct evaluation from \(\mathbf P=(\epsilon(r)-\epsilon_0)E_g\hat{\mathbf r}\) gives \(-r^{-1}\partial_r(rP_r)=+\epsilon_0E_g/r\), the same result. Material surfaces add bound charges \(P_r(b)\) on the outer radial face and \(-P_r(a)\) on the inner face. Integrating their surface contributions and the volume charge over a full annulus returns zero net bound charge, as required for a polarised neutral body. A constant radial electric magnitude can therefore coexist with zero free charge and nonzero total charge.

A manufactured graded material is often approximated by concentric homogeneous shells. For shell \(j\) from \(r_j\) to \(r_{j+1}\), its voltage drop at fixed \(\lambda\) is \(\lambda\ln(r_{j+1}/r_j)/(2\pi\epsilon_j)\). To reproduce the exact voltage drop of the continuously graded design over each shell, choose \(\epsilon_j=\epsilon_a a\ln(r_{j+1}/r_j)/(r_{j+1}-r_j)\). This matches electrode capacitance even with relatively few shells. Yet the field inside each discrete shell still falls as \(1/r\) and jumps at its interfaces. Matching terminal capacitance alone does not verify the target uniform-field profile. Compute the field just inside each shell edge and refine the radial layering against a local peak-field tolerance.

What a small displacement of the end electrode excites

An axisymmetric tube calculation retains only angular order \(m=0\). Now impose at the tube entrance a voltage profile proportional to \(r\cos\phi\) near the axis and taper it to zero at the wall. This is a dipolar lateral pattern with positive voltage on one side and negative on the other. Separating \(R(r)\cos(m\phi)e^{-kz}\) into Laplace's equation yields

\[(rR')'+\left(k^2r-\frac{m^2}{r}\right)R=0 .\]

The regular solutions are \(J_m(kr)\). Near the axis their leading powers are \(r^{|m|}\), so an \(m=1\) potential vanishes on the centreline while its transverse gradient generally does not. The grounded wall selects zeros of \(J_m\). The first zero of \(J_1\) is \(3.83171\), larger than the first axisymmetric zero, so the slowest lateral disturbance decays faster than the slowest axisymmetric voltage. Probe design therefore changes which decay laws are experimentally accessible.

For a cap shaped exactly as \(f=V_1J_1(jr/a)\cos\phi\), \(j=3.83171\), the whole solution is a single mode. Near the axis \(J_1(jr/a)\simeq jr/(2a)\); using \(r\cos\phi=x\),

\[V\simeq V_1 j x e^{-jz/a}/(2a).\]

Hence \(E_x(0,z)=-V_1 j e^{-jz/a}/(2a)\). With \(V_1=2.0\) V and \(a=10\) mm, the lateral field starts at \(383\) V/m and falls to \(8.30\) V/m after an axial distance equal to one radius. A centreline voltmeter sees zero at both positions and gives no hint of the finite transverse force. A pair of voltmeters at small opposite \(x\) or a field probe oriented along \(x\) measures the relevant derivative.

For a realistic shifted electrode the input can contain both \(m=0\) and \(m=1\). Place detectors at \((r,0,z)\) and \((r,\pi,z)\). Their average selects even azimuthal orders; their difference selects odd ones. The ratio of the difference at two heights tests \(m=1\) decay after higher odd modes subside. The average also includes \(m=2,4,\ldots\), so attributing it to \(m=0\) requires symmetry information or more angular sensors. Reversing the applied electrode displacement changes the sign of an odd response but leaves even corrections unchanged to leading order. This experiment links angular Fourier selection and radial eigenvalues to a measurable alignment tolerance without requiring an entire three-dimensional voltage map.

Project a ring source without calling an axis cell a point detector

Deposit a thin circular ring of total free charge \(q\) at radius \(s\) in the plane \(z=z_0\) inside a long grounded cylindrical tube. Its volume density in an axisymmetric model is \(q\,\delta(r-s)\delta(z-z_0)/(2\pi s)\), for \(s>0\). The \(2\pi s\) removes the circumference introduced by the volume element. A radial code that deposits \(q\) directly as a density in one mesh bin, without dividing by annular volume, changes the total charge each time the radius or mesh spacing changes. In this calculation one can track that normalisation all the way to a voltage coefficient.

Take the tube infinite in both axial directions for simplicity. Expand \(V=\sum_n v_n(z)J_0(j_n r/a)\) in the grounded radial eigenfunctions. Project Poisson's equation using weight \(r\,dr\) and the norm \(a^2J_1(j_n)^2/2\). The ring produces

\[[-d_z^2+(j_n/a)^2]v_n=\frac{q J_0(j_n s/a)}{\pi\epsilon a^2J_1(j_n)^2}\,\delta(z-z_0).\]

The infinite-line Green response for \(-d_z^2+k^2\) is \(e^{-k|z-z_0|}/(2k)\), as can be checked by integrating its derivative across \(z_0\). Thus each modal voltage has a finite amplitude and two decaying tails, and the complete field is obtained by summing radial modes. At a detector separated axially from the ring the exponential factors ensure rapid convergence. Exactly on the mathematical ring the local potential diverges logarithmically like that of a thin filament; comparing finite-element peak voltages there requires a finite wire cross section or a specified detector average.

An unexpected and testable consequence concerns the source radius. The coupling to mode \(n\) is proportional to \(J_0(j_n s/a)\). It becomes exactly zero when the source sits on a radial node of that mode. The second mode has an interior node at \(s/a=j_1/j_2\simeq0.4357\). A ring there still carries charge and excites many other modes but contributes no second modal coefficient. As an experimental analogy, a weighting potential that changes sign across part of a sensor can receive cancelling contributions from an extended excitation. Here the cancellation is encoded exactly in orthogonality and the pointwise coupling value.

A check independent of the ring-charge normalisation uses reciprocity. Imagine two narrow coaxial source/detector rings of radii \(s,r\), each with the same definition of total charge and voltage measured around its circumference. The modal response contains the symmetric product \(J_0(j_n s/a)J_0(j_n r/a)\) multiplied by a factor that depends only on axial separation. Swapping radius and axial position therefore leaves voltage per total charge unchanged. If a numerical table instead looks symmetric per charge density but not per total ring charge, check whether the radius-dependent integration weights were applied on both deposition and sampling.

Another useful test fixes total deposited charge but reduces a resolved annular thickness around \(s\). First compare with an integral of the analytic ring solution across the same finite distribution. Then take the thin-ring limit at a detector away from the deposition region. Taking grid thickness and source thickness to zero together while comparing a self-voltage at the source conflates numerical refinement with a mathematically singular observable. Stating detector location, normalisation and order of limits turns a superficially straightforward ring source into a robust benchmark for cylindrical Poisson solvers.

Measure a radial cylindrical mode

Change the electrode mode and compare radial nodes with axial decay. A cylindrical boundary chooses a different eigenbasis from a rectangular one.

A cylindrical interface can carry induced bound charge with an entirely radial field

Separate the two charges detected at a coaxial material boundary

A long coaxial gap contains two homogeneous radial layers with interface at \(s\), no free sheet there and fixed inner line charge \(+\lambda\). Find the bound interface charge per length, verify it from the field jump, and determine the interface radius at which the layers take equal voltages. Evaluate the result for \(a=2\) mm, \(b=18\) mm and relative permittivities 2 and 4.

Derive and check the result

For both regions \(D_r=\lambda/(2\pi r)\). In material \(i\) the polarisation is \(P_i=D_r(1-\epsilon_0/\epsilon_i)\) along the radial direction. At the interface the outer face of material 1 has bound density \(+P_1\), the inner face of material 2 has \(-P_2\). Their sum times the circumference gives bound line charge \(\lambda_b=\lambda(\epsilon_0/\epsilon_2-\epsilon_0/\epsilon_1)\). It equals \(-\lambda/4\) for the given ordering; the value per length is independent of \(s\) because the \(1/s\) field cancels the interface circumference. A local density meter would see a different value at a different radius even though the integrated result stays the same.

Direct use of Gauss's law for the true electric field gives \(\epsilon_0\,2\pi s(E_{2r}-E_{1r})=\lambda[\epsilon_0/\epsilon_2-\epsilon_0/\epsilon_1]\), confirming the sign and magnitude. A check with displacement alone gives zero jump and thus correctly reports no free charge at that same surface. The two field laws answer different questions. Extending the shell calculation to include both exterior material faces returns zero total bound charge per material, so the internal negative interface charge never represents a net creation of charge.

The voltage drops are proportional to \(\ln(s/a)/\epsilon_1\) and \(\ln(b/s)/\epsilon_2\). Equality gives \(s^{\epsilon_1+\epsilon_2}=a^{\epsilon_2}b^{\epsilon_1}\), or \(s=a(b/a)^{\epsilon_1/(\epsilon_1+\epsilon_2)}\), a dimensionally transparent form. Numerically \(s=2(9)^{1/3}=4.16\) mm. A half-voltage location at 4.16 mm is far from the arithmetic centre of this gap. It is also distinct from the 6.0 mm geometric mean for a homogeneous annulus, because the inner lower-permittivity layer needs less geometric thickness to take the same voltage.

Tutorial · radial modes with different physical boundaries

Replace the grounded wall by a reflecting boundary

A long tube has \(\partial_r V=0\) on its side instead of \(V=0\), and its end voltage profile is nonuniform. What happens to the radial eigenvalues and to the assertion that every end disturbance dies away?

Work through the solution

The wall now requires

\[J'_0(ka)=-J_1(ka)=0.\]

In addition a constant radial mode with \(k=0\) satisfies both side and axis conditions. Its axial equation is \(Z''=0\), so boundedness allows a constant component. The end profile's weighted cross-sectional mean supplies that persistent offset. Only the components orthogonal to the constant decay. Requiring the potential to tend to zero at infinity while prescribing a nonzero mean cap voltage would be incompatible for this insulated side model unless other boundaries or sources are introduced.

Infer a radial charge density from a coaxial reading

Suppose the measured potential in a coaxial gap is \(V=A\ln(b/r)+B(b^2-r^2)\) with constant permittivity. Determine the volume charge and the signs of its contribution to the two face fluxes. Which part can be changed by externally altering the applied voltage at fixed charge density?

Work through the solution

The logarithmic term is harmonic away from the excluded axis. For the quadratic term \(\nabla_r^2[-Br^2]=-4B\), giving uniform \(\rho=4\epsilon B\). The radial field is \(A/r+2Br\). The net outward displacement flux through the gap per length is \(2\pi\epsilon[bE(b)-aE(a)]=4\pi\epsilon B(b^2-a^2)\), exactly \(\rho\pi(b^2-a^2)\). At positive \(B\) the quadratic term contributes positive outer flux and negative inward-face flux, with the larger outer contribution from both area and field. Changing only the source-free boundary excitation adds a logarithmic term and, if the reference permits it, a constant. It alters both field readings without altering the inferred uniform volume density.

Further reading