Fundamentals / Physics / Electrodynamics / Numerical field laboratory

When differentiating a measured dipole invents radiated power

Infer dipole radiation from a sampled displacement and show quantitatively why position noise can dominate a seemingly well-resolved power estimate.

From trajectory to a physically meaningful quantity

An electrically small source carries an oscillating electric dipole moment \(p(t)=p_0\cos\omega t\) in a fixed direction. In nonrelativistic electric dipole radiation, the total instantaneous far-zone power associated with retarded time is

\[P=|\ddot p|^2/(6\pi\epsilon_0c^3).\]

The average over a single sinusoidal cycle is \(p_0^2\omega^4/(12\pi\epsilon_0c^3)\). The fourth power of frequency expresses a physical sensitivity, but a numerical second derivative can introduce a separate sensitivity to high-frequency measurement errors.

A sensor supplies moment or displacement samples at times \(t_j=jh\). If the source is a known rigid displacement \(x(t)\) of charge \(q\), then \(p=qx\). The constant conversion from moment to displacement cancels when comparing a numerical power with a reference power. We therefore scale amplitude by \(p_0\) and time by \(1/\omega\). The true acceleration trace is \(-\cos t\). Comparing it with the estimated acceleration before squaring reveals signs and phases that a power curve conceals.

Derive the frequency response of the differentiation formula

Use \(D_2p_j=(p_{j-1}-2p_j+p_{j+1})/h^2\). On a complex exponential \(e^{i\nu jh}\) the symbol is \(-4\sin^2(\nu h/2)/h^2\). Dividing its magnitude by the exact \(\nu^2\) gives a squared sinc factor. At a fixed physical frequency the error is quadratic in \(h\). For a signal oscillating in sign from one sample to the next, \(\nu h=\pi\), and the numerical second derivative multiplies its amplitude by \(4/h^2\). A numerical derivative smooths the very highest frequency relative to an exact high-frequency derivative yet still strongly amplifies the raw high-frequency component relative to a low-frequency physical acceleration.

Add a deliberately reproducible alternating error \(\epsilon(-1)^j\) to the position readings. Its acceleration error is \(-4\epsilon(-1)^j/h^2\). Squared and averaged over a complete even grid, the alternating error and the fundamental are orthogonal. Therefore the normalised inferred mean power becomes

\[\frac{\langle P_\mathrm{est}\rangle}{\langle P_\mathrm{true}\rangle}\]

=\left[\frac{\sin(h/2)}{h/2}\right]^4+2\left(\frac{4\epsilon}{h^2}\right)^2 .

The first term tends to one from below as sampling is refined. At a fixed per-sample alternating displacement amplitude the second grows as \(h^{-4}\). The experiment holds a particular *sampling-related* error fixed; it does not claim that all real noise changes frequency when the sampling rate changes. A fixed-frequency physical disturbance obeys the symbol at its own fixed \(\nu\).

A numerical example in which refinement hurts

For 32 samples per period, \(h=2\pi/32\simeq0.19635\), and a positional disturbance two parts per thousand of full amplitude gives a spurious acceleration peak about 0.2075 of the true peak. Position data plotted at ordinary scale can look nearly perfect. The normalised mean-square acceleration is already about 1.080. At 64 samples per period with the same alternating error the spurious acceleration amplitude grows fourfold, and its contribution to mean power grows sixteenfold.

Set the perturbation to zero first and verify the approach to one as the physical sinusoid becomes increasingly well resolved. Restore the perturbation and determine which combination of resolution and disturbance first incurs a ten-per-cent error. The error can initially decrease and later increase with sample rate. Choosing the estimate that happens to lie closest to one at a single resolution can hide a cancellation between physical-mode discretisation error and positive noise power.

Recover a physical model without claiming information you did not measure

If an independent measurement shows the source contains only one sinusoidal frequency, fit its sine and cosine coefficients to the positions rather than differentiating every neighbour. On a full uniformly sampled cycle these coefficients are orthogonal to the alternating offset. Multiplying the fitted phasor by \(-\omega^2\) gives the model-based acceleration. This can be a much more precise estimate, but it assumes other harmonics are absent or irrelevant. A weak physical second harmonic has an acceleration amplification of four and power weighting of sixteen relative to equal moment amplitude. Validate the assumed spectrum before suppressing it.

For broad-band signals one may fit a smooth basis with an explicit high-frequency cutoff or use a model of detector bandwidth. Record the chosen cutoff, its physical justification and the uncertainty propagated into power. Repeating the computation with nearby cutoffs is a test of robustness, not a derivation of the correct filter. Where possible, compare the inferred radiated energy with a distant calibrated flux measurement over the same retarded-time interval. These two measurements have different systematic errors.

Tutorial

Independent, zero-mean random sample errors have variance \(\sigma_p^2\). What is the variance in one centred second derivative and why need adjacent derivative errors not be independent?

Work through the solution

The weights are \(1,-2,1\) divided by \(h^2\). Independence of the original samples gives variance \(6\sigma_p^2/h^4\). Adjacent derivative estimates share two original samples with nonzero weights, so their covariance is generally nonzero.

A second physical harmonic has amplitude 5% of the fundamental. How much does it contribute to the total time-averaged electric-dipole radiation, assuming orthogonal harmonics over the record?

Work through the solution

Its acceleration amplitude relative to the fundamental is

\[0.05\times2^2=0.2.\]

Its mean power is \(0.2^2=0.04\) of the fundamental contribution, about 3.85% of their sum. A source spectrum small in displacement need not be equally small in radiated power.

Why must a measured power spectrum specify whether it represents one-sided or two-sided frequencies?

Work through the solution

A real signal contains conjugate spectral amplitudes at opposite frequencies. A one-sided positive-frequency spectrum usually combines their powers. Counting both after applying such a convention doubles the inferred variance and radiation power.