Fundamentals / Physics / Electrodynamics / Magnetism, induction and field dynamics

Flux linkage, coupled coils and magnetic coenergy

A winding links flux through each turn. In two windings the current in either one can change the voltage in the other. A matrix of flux linkages describes this coupling, but predicting power or mechanical force requires specifying the current directions and the control conditions.

Measure a linkage rather than a field at one point

Choose a positive traversal direction for every turn of winding \(i\). Define \(\lambda_i=\sum_{\rm turns}\int\boldsymbol B\cdot d\boldsymbol a\) with normals consistent with traversal. If every turn sees equivalent flux, this is \(N_i\Phi_i\); a distributed winding can have significantly different flux per turn. A passive terminal reference takes current entering the positive terminal. For a stationary winding with series resistance \(R_i\), its terminal voltage then obeys \(v_i=R_i I_i+d\lambda_i/dt\). The opposing internal induced emf is \(-d\lambda_i/dt\). These statements use different definitions of voltage direction, so the opposite signs are consistent.

To measure a differential inductance at fixed geometry, one may superimpose a small sinusoidal current on a DC bias, measure its voltage quadrature, and infer \(d\lambda/dI\). A large slow ramp instead measures finite changes in linkage by integrating \(v-RI\) over time. If the winding warms during the ramp, using a cold resistance biases the flux integral. At sufficiently high frequency winding capacitance, frequency-dependent conductor resistance and nonuniform flux can invalidate the simple two-terminal model. Entering the source's physical boundary and frequency regime is part of interpreting any inferred inductance.

Derive reciprocity and energy from the field equations

For a linear reciprocal material with fixed geometry and no remanent background, write \(\lambda_i=\sum_jL_{ij}I_j\). In free space the Neumann double line integral for distinct slender loops is unchanged when loop indices are exchanged, giving \(L_{12}=L_{21}\). For a broader proof take field solutions \((\boldsymbol H_i,\boldsymbol B_i,\boldsymbol A_i)\) for unit currents in windings \(i\). The linked flux in winding \(j\) is \(\int\boldsymbol A_i\cdot\boldsymbol J_j\,dV\), where \(\boldsymbol J_j\) is its unit-current density. Integrate \(\boldsymbol A_i\cdot(\nabla\times\boldsymbol H_j)\) by parts. With appropriate enclosing conditions the surface term vanishes and the integral is \(\int\boldsymbol B_i\cdot\boldsymbol H_jdV\). Since the permeability tensor is symmetric, exchanging \(i,j\) gives the same value. Reciprocity depends on the constitutive law and boundary conditions.

At fixed mechanical coordinates the electrical work put into the field is \(dW=\sum I_i\,d\lambda_i\) after subtracting losses. Ramp all currents up in fixed proportion from zero and use linearity. The instantaneous integrand scales linearly with fractional ramp amplitude, giving half its endpoint product:

\[W=\tfrac12\sum_i I_i\lambda_i=\tfrac12 L_1I_1^2+MI_1I_2+\tfrac12 L_2I_2^2,\qquad |M|\le\sqrt{L_1L_2}.\]

The inequality follows from requiring nonnegative energy for every current vector. At fixed \(I_2\), minimise the quadratic with respect to \(I_1\); at \(I_1=-MI_2/L_1\) energy is \((L_2-M^2/L_1)I_2^2/2\). Thus no passive linear pair can have coupling magnitude greater than the geometric mean of its self-inductances. Equality corresponds to a combination of currents producing zero linked-field energy in the ideal model, as for perfect coupling without leakage. In an actual device leakage, parasitics and measurement uncertainty matter close to that limit.

Background · Can zero mutual flux coincide with maximum torque?

Consider a small coil that rotates in the nearly uniform field of a fixed coil. For a suitable angle origin the linked flux is proportional to the projected area, so \(M(\theta)=M_0\cos\theta\). Hold both currents fixed with ideal supplies. In a linear medium the angle-dependent part of the magnetic coenergy is \(M(\theta)I_1I_2\). Its derivative gives the torque.

\[\tau_\theta=I_1I_2\,\frac{dM}{d\theta}=-M_0I_1I_2\sin\theta.\]

Precisely at a right angle the instantaneous mutual linkage is zero while its angular derivative has maximum magnitude. A freely rotating current loop therefore feels its largest aligning torque there. Measuring linkage at one orientation cannot supply this force. Measuring it at two nearby angles estimates the derivative that enters the mechanical response.

Reverse a connection and include a shorted secondary

Consider \(L_1=9.0\,\mathrm{mH},L_2=4.0\,\mathrm{mH},M=4.8\,\mathrm{mH}\), so coupling coefficient \(k=M/\sqrt{L_1L_2}=0.80\). With currents \(I_1=0.40\) A and \(I_2=-0.20\) A, the flux linkages are \(2.64\,\mathrm{mWb}\) and \(1.12\,\mathrm{mWb}\) using the signed references. The energy is

\[(0.40\times2.64-0.20\times1.12)/2=0.416\,\mathrm{mJ}.\]

Reversing only the second physical winding while keeping the named terminal references changes the mutual sign but leaves the diagonal self terms positive.

Connect the coils in series. When the same signed current flows in both, the total linkage along the series path gives

\[L_{\rm aid}=L_1+L_2+2M=22.6\,\mathrm{mH}.\]

With opposite reference directions the result is

\[L_{\rm oppose}=L_1+L_2-2M=3.4\,\mathrm{mH}.\]

The difference of the measured series inductances divided by four estimates the signed mutual coupling for the chosen assignment. Both inferred inductances are nonnegative. A negative value obtained from a model suggests incorrect signs, units or incompatible measurements.

Now close winding two through an ideal lossless short while holding geometry fixed. With zero initial secondary linkage the voltage condition \(d\lambda_2/dt=0\) implies \(I_2=-(M/L_2)I_1\), hence \(\lambda_1=(L_1-M^2/L_2)I_1\). In the example the input inductance becomes \(3.24\,\mathrm{mH}\), smaller than the open-secondary value of \(9.0\). Its reduction is not the same calculation as series opposition; the secondary current is determined by a flux constraint rather than imposed as \(-I_1\). With finite secondary resistance the DC steady secondary current eventually returns to zero. The notion of a perfectly shorted, flux-conserving secondary is an ideal time-scale limit.

See the secondary's losses from the primary

For sinusoidal current use peak phasors with \(e^{i\omega t}\). Let the full secondary resistance be \(R_2\) and close it without an applied voltage. Solve \(0=(R_2+i\omega L_2)\widetilde I_2+i\omega M\widetilde I_1\), then substitute into the primary equation. The input impedance becomes

\[Z_{\rm in}=R_1+i\omega L_1+\frac{\omega^2M^2}{R_2+i\omega L_2}.\]

The additional real part \(\omega^2M^2R_2/[R_2^2+(\omega L_2)^2]\) is positive and represents power dissipated in winding two. Its imaginary part is negative and reduces the primary reactive voltage. In the high-frequency limit within the lumped model the reactive term tends towards \(i\omega(L_1-M^2/L_2)\). In the low-frequency limit the induced coupling vanishes quadratically in the real part. A sense of physical scale is obtained by choosing \(\omega=250\,\mathrm{s^{-1}}\) and \(R_2=1.0\,\Omega\). Then

\[\omega L_2=1.0\,\Omega,\omega M=1.20\,\Omega.\]

The added impedance is \(1.44/(1+i)=0.72-0.72i\,\Omega\), so a primary with negligible resistance sees \(0.72+1.53i\,\Omega\).

With primary amplitude \(1.0\) A, the secondary amplitude is

\[1.20/\sqrt2=0.849\,\mathrm{A}.\]

Its mean Joule loss is

\[0.849^2(1.0)/2=0.360\,\mathrm{W}.\]

Independently the primary's reflected resistance draws \(1.0^2(0.72)/2=0.360\) W. This agreement tests the sign of the induced secondary current and the correct use of peak versus rms amplitudes. Reversing the secondary orientation flips its voltage reference and its current phase by \(\pi\), but the reflected impedance depends on \(M^2\) and is unchanged.

Let geometry move while current is maintained

If a mechanical coordinate \(x\) changes, terminal electrical work can go into both field energy and mechanical output. For a reversible device \(dW_{\rm field}=\sum I_i d\lambda_i-F_xdx\). Introduce coenergy \(W'=\sum I_i\lambda_i-W_{\rm field}\); the product rule gives

\[dW'=\sum\lambda_i dI_i+F_xdx.\]

Therefore force at fixed currents is \(F_x=(\partial W'/\partial x)_{\boldsymbol I}\). At fixed linkages instead,

\[F_x=-(\partial W_{\rm field}/\partial x)_{\boldsymbol\lambda}.\]

A linear reversible system has \(W'=W_{\rm field}\) at each state, but their natural independent variables differ. Differentiating the same algebraic expression under an inappropriate constraint reverses a force prediction.

Suppose translating one coil increases \(M\) at \(0.20\,\mathrm{H/m}\), while its self-inductances are approximately constant. For maintained \(I_1=0.40\,\mathrm A,I_2=0.30\,\mathrm A\), \(F_x=I_1I_2\,dM/dx=0.024\,\mathrm N\) in the direction of increasing coupling. If \(x\) changes by \(1.0\) mm slowly, the field energy rises \(24\,\mu\mathrm J\). Source work from both windings is twice this value because both linkages change. The remaining \(24\,\mu\mathrm J\) goes to mechanical output. With currents of opposite sign the force reverses. The mechanism is the same as that behind an electromechanical transducer, but the sign is easier to see in a reciprocal two-port than in a one-coil moving-core drawing.

Check force by differentiating magnetic coenergy

Split the resonances of two coupled electrical oscillators

Close each winding through its own identical capacitor \(C\), remove resistance initially, and take identical self-inductances \(L\). Let \(q_1,q_2\) be capacitor charges in orientations for which \(I_i=\dot q_i\) and the passive capacitor voltage drop is \(q_i/C\). The two source-free loop equations become

\[L\ddot q_1+M\ddot q_2+q_1/C=0,\]
\[M\ddot q_1+L\ddot q_2+q_2/C=0.\]

Adding and subtracting decouple the symmetric coordinate \(q_1+q_2\) and antisymmetric coordinate \(q_1-q_2\). Their angular frequencies are \(1/\sqrt{(L+M)C}\) and \(1/\sqrt{(L-M)C}\) respectively. Thus the pair measures \(L+M\) and \(L-M\) independently of any assumption that current remains confined to the driven winding.

For \(L=10.0\,\mathrm{mH},M=2.0\,\mathrm{mH}\) and \(C=1.0\,\mu\mathrm F\), the uncoupled frequency is \(1592\) Hz. The symmetric mode lies at \(1453\) Hz, the antisymmetric at \(1779\) Hz. A sensor observing one coil after an initial excitation may see both: with \(q_1(0)=q_0,q_2(0)=0\) and both currents zero, \(q_1=q_0[\cos(\omega_s t)+\cos(\omega_a t)]/2\), while \(q_2=q_0[\cos(\omega_s t)-\cos(\omega_a t)]/2\). The envelope of the first can almost vanish as energy appears in the second. Energy has not been externally driven during this interval. The coupled magnetic cross term is part of the complete energy, so simply adding the two uncoupled winding energies at arbitrary instants can give an apparent oscillation of the total.

Inverse measurement is possible. If the two frequencies are \(f_s,f_a\), eliminate unknown \(C\) to get \(M/L=(f_a^2-f_s^2)/(f_a^2+f_s^2)\) for the stated same-sign winding labels. If frequencies alone are known but one cannot tell which mode carries same-sign current, one obtains the magnitude of the coupling. Measuring the relative current phase identifies the assignment. Unequal capacitances, unequal self-inductances or appreciable damping change the eigenvalue problem, so a frequency splitting should not be identified with \(2M\) or with a material coupling independent of the circuit model. A loss measurement can differentiate genuine normal-mode splitting from two overlapping modes broadened by resistance.

Recover transformer relations and identify the leakage mode

An ideal high-permeability closed core links all turns by a common flux \(\Phi\), so

\[\lambda_1=N_1\Phi,\ \lambda_2=\pm N_2\Phi.\]

Its terminal induced voltage ratio follows on differentiation, \(v_2/v_1=\pm N_2/N_1\) when resistive drops and parasitic voltages are negligible. The relation is between oriented time derivatives, not a rule about the magnitude of any static potential across a disconnected winding. A DC voltage held across a resistanceless winding would ramp the core flux indefinitely in this ideal model; a real core saturates or winding resistance establishes a different state. The harmonic transformer approximation operates within a finite flux and frequency range.

For a linear core with reluctance \(\mathcal R\), \(\Phi=(N_1I_1+N_2I_2)/\mathcal R\) with consistent orientations. Thus \(L_1=N_1^2/\mathcal R,\ L_2=N_2^2/\mathcal R,\ M=N_1N_2/\mathcal R\). The inductance matrix has a zero eigenvalue since the current combination \(N_1I_1+N_2I_2=0\) creates no core flux. Real leakage breaks this exact cancellation. Adding small series leakage inductances corresponds to storing additional positive energy outside the common flux region. The shorted-secondary input test is particularly sensitive to this residual storage because the coupled part largely cancels.

Take an 80-turn primary and 20-turn secondary on the same linear core. With 4.0 V rms across the magnetising branch at 2.0 kHz, sinusoidal flux amplitude follows from \(V_{\rm rms}=N_1\omega\Phi_{\rm peak}/\sqrt2\), yielding \(5.63\,\mu\mathrm{Wb}\). A \(2.0\,\mathrm{cm^2}\) core then sees \(0.0281\) T peak. The open secondary gives 1.0 V rms. A \(5.0\,\Omega\) resistive secondary load would draw 0.20 A rms and dissipate 0.20 W in the ideal lossless-transformer limit. The load-related primary current is then 0.050 A rms, corresponding to a reflected resistance of \(4.0/0.050=80\,\Omega\), as given by \((N_1/N_2)^2R_L\). An additional reactive magnetising current is needed for finite \(\mathcal R\); a primary ammeter can consequently read more than the reflected load component even with negligible winding power loss.

Halving drive frequency at unchanged voltage doubles peak flux. This can increase saturation and harmonic distortion even though a naive turns-ratio calculation still predicts the same rms open-circuit voltage. Repeating the experiment with unchanged voltage-to-frequency ratio instead holds the ideal peak flux fixed. These different protocols distinguish a failure of flux linearity from simple winding loss. They also show why mutual inductance as a constant scalar is a model tied to a current, geometry and frequency range. Its measurement should specify the secondary termination, DC bias and whether the observed winding responds to essentially all the changing flux.

Infer force from linked flux

Change the coil geometry and current while checking which electrical variable is held fixed in the mechanical derivative.

Compute the reaction of a ring that conserves its flux linkage

A primary coil is held at current \(I_1\) by an ideal supply. Along its axis a second closed coil can move with coordinate \(x\). The two self-inductances \(L_1,L_2\) may be treated as constants, while their mutual inductance \(M(x)\) increases as the centres approach. Choose both winding directions so that aiding positive currents produce positive \(M\). Imagine first that resistance in the secondary is negligible over the entire experiment. Faraday's circuit equation then conserves its total linkage \(\lambda_2=L_2I_2+M(x)I_1\). The conserved quantity is fixed by the preparation of the ring, so an unreported initial field can change even the sign of the force.

Begin with zero secondary linkage. As the two coils approach at fixed current \(I_1\), positive linkage from the primary grows and the secondary current must become negative. Its value is

\[I_2=-MI_1/L_2.\]

For two linear windings the magnetic coenergy with the instantaneous currents independently specified is \(W'=(L_1I_1^2+2MI_1I_2+L_2I_2^2)/2\). The mechanical force is the derivative with respect to \(x\) at fixed winding currents. Take that partial derivative first to get \(F_x=I_1I_2M'(x)\), and then insert the actual secondary current. At zero trapped linkage this gives

\[F_x=-\frac{I_1^2}{L_2}M(x)M'(x).\]

For an approach coordinate that increases toward stronger coupling, the sign is negative. Magnetic induction supplies a restoring tendency against entry into the high-coupling region. The measured primary linkage is \([L_1-M^2/L_2]I_1\), which gives the same terminal inductance previously found from a short circuit at sufficiently high frequency in the linear model. With zero trapped linkage the stored energy also reduces to \(I_1^2[L_1-M^2/L_2]/2\). For fixed current and moving coils the supply exchanges energy. Its work \(I_1\,d\lambda_1\) must be retained when using a field-energy calculation to deduce mechanical force.

For example, let \(L_1=20\,{\rm mH}\), \(L_2=5.0\,{\rm mH}\), \(M=3.0\,{\rm mH}\), \(M'=0.12\,{\rm H/m}\), and \(I_1=0.50\,{\rm A}\). The secondary current is \(-0.30\,{\rm A}\), the effective primary inductance is \(18.2\,{\rm mH}\), and the force is \(-0.018\,{\rm N}\). The coupling coefficient \(M/\sqrt{L_1L_2}=0.30\) satisfies positive energy. A small approach of \(1.0\,{\rm mm}\), over which this local gradient varies negligibly, gives approximately \(-18\,\mu{\rm J}\) of work by the magnetic force. The external apparatus must do positive work to maintain a slow approach.

Now prepare a positive trapped linkage \(3.0\,{\rm mWb}\), with all the other numerical data unchanged. The secondary current is \((\lambda_2-MI_1)/L_2=+0.30\,{\rm A}\), so the same geometry attracts with \(+0.018\,{\rm N}\). This reversal comes from the initial state of the secondary. The threshold \(MI_1=\lambda_2\) gives zero secondary current and hence zero force at that point, although the primary still stores field energy. For a permanently closed ideal conductor the trapped linkage must be specified separately. Applying a steady-field circuit equation with zero resistance and zero terminal voltage does not determine its current by itself.

What changes if the secondary has a small measured resistance and the motion stops immediately after the first force reading?

Work through the solution

Once the coils and the primary current are stationary, mutual linkage from the primary stops changing. The secondary equation becomes

\[L_2\,dI_2/dt+R_2I_2=0.\]

The current and the magnetic force decay together with time constant \(L_2/R_2\). With \(R_2=0.10\,\Omega\) that time is \(50\,{\rm ms}\), and the initially measured force has fallen to about \(37\%\) after one time constant. A slowly moving ordinary ring can lose much of its induced current during motion. A fast passage can resemble the conserved-linkage limit even when a later static reading shows no induced force.

A second student substitutes a nonzero conserved linkage into the stored field energy and differentiates at fixed \(I_1\). Why does this prescription miss the extra trapped-current force?

Work through the solution

Substitution puts the field energy in the form \(W=(L_1-M^2/L_2)I_1^2/2+\lambda_2^2/(2L_2)\). At fixed \(I_1,\lambda_2\) it has no term linear in trapped linkage. The source work does. The primary linkage is \(\lambda_1=(L_1-M^2/L_2)I_1+M\lambda_2/L_2\). At fixed primary current, subtract \(dW\) from \(I_1d\lambda_1\) and divide by \(dx\). The resulting mechanical force is \(I_1(\lambda_2-MI_1)M'/L_2\), precisely the independently evaluated mutual force. An energy derivative determines a force only after the controlled variables and any energy supplied at electrical terminals have been identified.

David Tong, Electrodynamics, on mutual inductance and field energy.

Tutorial on electrical and mechanical constraints

A winding pair measures 35 mH in series aiding and 11 mH in series opposing. The first self-inductance is 16 mH. Infer the second, mutual coupling, and primary inductance with the ideal secondary shorted.

Work through the solution

Adding the readings gives \(2(L_1+L_2)=46\) mH, so \(L_2=7\) mH. Their difference gives \(4M=24\) mH, hence \(M=6\) mH and \(|k|=6/\sqrt{112}=0.567\). The shorted-secondary primary value is

\[16-36/7=10.86\,\mathrm{mH}.\]

For a single ideal coil, \(L\) increases from 2.0 to 3.0 mH while a source holds current at 0.50 A. Find the change of magnetic energy, source work and mechanical output. Compare to a separate isolated lossless coil with the same initial current and conserved linkage.

Work through the solution

At fixed current the stored energy rises by \((0.5)^2(0.001)/2=0.125\) mJ. Source work is \(I^2\Delta L=0.250\) mJ, leaving 0.125 mJ mechanical. For the isolated coil \(\lambda=1.00\) mWb stays fixed and energy falls from 0.250 to \(0.167\) mJ. The released 0.0833 mJ supplies mechanical output without source work.

A sinusoidal test infers a negative reflected resistance in a pair of ordinary passive stationary windings with a passive termination. Which steps would you check before interpreting it physically?

Work through the solution

Verify primary and secondary voltage/current reference directions and the distinction between a passive port voltage and the internally induced emf. Then check calibration phase, instrument delay, any active load, and the subtracted winding resistance. The passive model's reflected real part is explicitly nonnegative for \(R_2\ge0\), regardless of the sign of \(M\).