When a suspended capacitor loses its stable equilibrium

An electrode suspended on a spring can remain motionless at a bias that makes the calculated electrostatic force grow as it moves. Static force balance alone misses the voltage at which that equilibrium disappears. Deriving the small-signal frequency gives an independent measurement of the same instability.

Start with the electrical and mechanical control variables

A movable conducting plate of area \(A\) faces a fixed electrode. Its unstressed gap is \(g\). Define positive displacement \(x\) toward the fixed plate, with spring force \(-kx\), mass \(m\) and viscous damping coefficient \(b\). For \(0\le x<g\) assume ideal parallel plates, negligible tilt and fringing, constant \(\epsilon\), and a linear elastic spring. The capacitance is \(C(x)=\epsilon A/(g-x)\). The model ends when the plates approach contact or when the suspending structure departs from its specified elastic law. It cannot by itself calculate adhesion, contact resistance or post-contact motion.

Before differentiating electrical energy specify whether the source holds voltage or charge. At fixed charge \(Q\), electrical energy is \(Q^2/[2C(x)]\), and its negative displacement derivative gives the force toward increasing \(x\). At fixed voltage \(V\), a source supplies \(VdQ\) as the plates move. The appropriate potential for mechanical equilibrium is the spring energy plus the field energy minus \(QV\), which here is \(\mathcal U_V=kx^2/2-C(x)V^2/2\). Differentiating gives the outward spring reaction and the attractive electrical force \(F_e=V^2C'(x)/2=\epsilon A V^2/[2(g-x)^2]\). An independent derivation multiplies the conductor pressure \(\epsilon E^2/2\) by area with \(E=V/(g-x)\). Both give a positive force. Replacing the source potential with the stored energy at fixed voltage would reverse its sign.

Locate all equilibria before choosing a branch

Define \(s=x/g\) and \(\Lambda=\epsilon A V^2/(2kg^3)\). The static force equation reduces to

\[\Lambda=s(1-s)^2.\]

At a specified voltage one can find \(s\) by scanning the curve \(s\mapsto s(1-s)^2\) over the physically admissible interval \(0\le s<1\). Its derivative is \((1-s)(1-3s)\), giving an interior maximum \(4/27\) at \(s=1/3\). For \(0<\Lambda<4/27\) there are two physical roots. The smaller is a local minimum of \(\mathcal U_V\) while the larger is a local maximum. Their merger is a fold of the static equilibrium branch:

\[x_{\rm pi}=g/3,\]
\[V_{\rm pi}=\sqrt{\frac{8kg^3}{27\epsilon A}} .\]

The often-quoted one-third displacement is the result for a linear spring, ideal voltage drive and this capacitance geometry. It is not a universal travel limit determined by the gap alone. Additional mechanical restoring forces or a different electrical boundary condition change the fold. Neither positive net electrical force nor the mere existence of a real solution is evidence of stable operation. A root finder started near the almost closed gap can converge to the unstable large-displacement root with an extremely small static residual.

The two branches can be distinguished experimentally without deliberately reaching contact. At static equilibrium \(kx=F_e\). Linearise the total force about \(x_0\) while maintaining voltage at its prescribed value. The incremental restoring stiffness and corresponding weak-damping natural frequency are

\[k_{\rm eff}=k-\frac{\epsilon A V^2}{(g-x_0)^3}=k\,\frac{1-3s_0}{1-s_0},\]
\[f_{\rm small}=\frac1{2\pi}\sqrt{\frac{k_{\rm eff}}m}.\]

A small push toward the fixed electrode is restored only when \(k_{\rm eff}>0\). The familiar electrostatic softening is the reason the smaller equilibrium is stable. The small-signal frequency tends to zero as the fold is approached. With appreciable damping the observed amplitude resonance and ringdown oscillation have slightly different frequencies; fit the full mechanical response rather than identifying an arbitrary peak with the undamped \(f_{\rm small}\).

Background · Can a sudden step pull in a statically stable actuator?

An ideal voltage step applied to a plate initially at rest can push it past the unstable equilibrium. During the motion at fixed voltage the effective potential per \(kg^2\) is \(u(s)=s^2/2-b/[2(1-s)]\), where \(s=x/g\) and \(b=\epsilon A V^2/(kg^3)\). Neglect damping and begin at \(s=0\). At the dynamical threshold the initial energy equals the saddle energy and the slope vanishes at that saddle.

\[u(s)=u(0)\ \Longrightarrow\ b=s(1-s),\]
\[u'(s)=0\ \Longrightarrow\ b=2s(1-s)^2.\]

The two equations meet at \(s=1/2\), \(b=1/4\). The quasistatic fold gives \(b=8/27\). Consequently the undamped step threshold is only \(\sqrt{27/32}\simeq0.919\) times the slow-ramp pull-in voltage. A device operated between the two voltages can survive a ramp but collapse after an abrupt step. Dissipation and the actual rise time change this prediction.

Reconstruct the prepared state from a frequency measurement

Take a 100 μm square electrode in vacuum, \(g=2.00\) μm, \(k=2.00\) N/m and \(m=5.00\times10^{-10}\) kg. The predicted pull-in voltage is 7.32 V, the zero-bias capacitance 44.3 fF and the zero-bias natural frequency 10.07 kHz. On the low branch \(s_0=0.20\) gives \(x_0=0.400\) μm and voltage 6.80 V. Then \(k_{\rm eff}=1.00\) N/m and the small-signal frequency is 7.12 kHz. A measured frequency ratio \(f/f_0\) can be inverted via \(s=(1-r)/(3-r)\), where \(r=(f/f_0)^2\). The result is independent of absolute optical displacement calibration if the mass and underlying spring stiffness have not changed during the bias sweep.

At the same voltage the other physical root is \(s=0.48769\). A numerical force balance at this root would give the same supply reading but a negative tangent stiffness. The ideal voltage-controlled potential in units \(kg^2\) is \(u(s)=s^2/2-\Lambda/(1-s)\). The barrier height \(kg^2[u(0.48769)-u(0.20)]\) for this example is \(7.26\times10^{-14}\) J. A sufficiently energetic disturbance can carry the plate out of the stable basin even below static pull-in. This is different from loss of the static equilibrium itself. A quasistatic model predicts the existence and local stiffness of the equilibrium; a transient simulation must additionally specify initial displacement, velocity, drive ramp and damping.

Change the preparation to fixed charge

Disconnect a perfect isolated capacitor after placing a known charge \(Q\) on it, neglecting leakage and parasitic capacitance. Then \(F_Q=Q^2/(2\epsilon A)\) is independent of the remaining gap, because \(D=Q/A\) is fixed. Static equilibrium is \(x_0=Q^2/(2\epsilon A k)\), with incremental stiffness exactly \(k\). At the same initial voltage and gap the instantaneous force agrees with the voltage-controlled value, since \(Q=C(x_0)V\). The derivatives governing subsequent motion differ. At \(x_0=0.400\) μm the required charge in the numerical example is \(0.376\) pC. After ideal electrical isolation the small-signal frequency returns to the underlying elastic value even though the loaded static position stays the same.

Ideal charge isolation is delicate in a small device. A fixed parasitic capacitance \(C_p\) from the isolated node to a reference means the conserved charge belongs to \(C(x)+C_p\). Motion changes the fraction of total charge residing on the actuator. The electrical energy becomes \(Q_{\rm total}^2/[2(C+C_p)]\), so the force is \(Q_{\rm total}^2 C'/[2(C+C_p)^2]\), generally displacement dependent. If \(C_p\gg C\), the node voltage changes little with a small displacement and behavior is closer to voltage control. Interpreting an observed softening after disconnecting the supply as evidence against electromagnetic force balance would overlook this boundary change.

A different practical preparation puts an intentional series capacitor \(C_s\) between a fixed voltage supply and the actuator. Its series combination is \(C_{\rm ser}=\epsilon A/[g-x+\epsilon A/C_s]\). For static mechanical work at fixed supply voltage use \(F=V_s^2 C_{\rm ser}'/2\). Defining an effective electrical spacing \(g_e=g+\epsilon A/C_s\), the static fold occurs at \(x=g_e/3\) if this lies within the open physical gap. If \(\epsilon A/C_s\ge2g\), contact would occur before any such static fold in the ideal model. This calculation shows a direct connection between passive circuit design and allowed mechanical travel, while making clear that the maximum actuator voltage can differ from the voltage printed on the supply.

Why a sudden voltage change can reach contact below static pull-in

For a rapid electrical step the plate has a position and velocity inherited from the previous preparation. Suppose it starts at rest at its zero-bias position, the supply steps to a constant \(V\) much faster than a mechanical period, and mechanical damping is initially negligible. Immediately after the step, energy in the mechanical potential \(u(s)=s^2/2-\Lambda/(1-s)\) is \(u(0)=-\Lambda\) in units of \(kg^2\). Motion under this constant voltage can reach the force barrier if the initial value exceeds the potential at the unstable stationary point. This question can be solved by comparing two energies without integrating an entire time history.

Let \(s_b\) be the unstable root of \(\Lambda=s_b(1-s_b)^2\). At threshold the initial state is on the separatrix, the trajectory separating oscillations in the well from excursions to the closing gap. Set \(u(0)=u(s_b)\), subtract the two expressions and cancel \(s_b\) from the nontrivial solution. The two conditions become

\[\Lambda={s_b(1-s_b)\over2},\]
\[\Lambda=s_b(1-s_b)^2 .\]

Thus \(s_b=1/2\), \(\Lambda=1/8\), and the ideal undamped step threshold is

\[V_{\rm step}/V_{\rm pi}=\sqrt{27/32}=0.919.\]

In our example this is 6.72 V. A slow increase to 6.80 V leads to the observed stable 0.40 μm deflection, whereas a sudden ideal voltage step to the same value from rest at the origin contains enough energy to escape the well. Starting on the biased equilibrium before applying a small perturbation is a different experiment. The direction of the threshold shift makes physical sense: damping removes mechanical energy during the first excursion, and a slow ramp allows the equilibrium to move with the plate. The undamped value specifies a particular ideal initial-value experiment, rather than a voltage rating for an unspecified drive waveform.

One can check a simulated step by monitoring \(m\dot{x}^2/2+\mathcal U_V\) after the supply settles. With viscous damping its derivative is \(-b\dot{x}^2\), so any sustained increase during a constant-voltage segment points to a numerical or modelling error. Before the step ends there is an explicit drive term \(-CV\dot V\) in this energy balance. The mechanical potential already includes the source work. Adding \(V\dot Q\) to the same balance a second time gives an artificial energy imbalance. A transient solver should stop at a physically specified minimum gap instead of marching across the singularity; a statement about contact time depends on what counts as contact.

A finite source resistance changes what a ringdown measures

A dc supply with series resistance \(R\) can maintain the static voltage accurately while failing to hold the actuator voltage fixed over a mechanical cycle. Let its steady node voltage be \(V\), with equilibrium capacitance \(C=C(x_0)\). A small sinusoidal displacement \(\delta x\) causes current \(i\omega(C\,\delta v+VC'\delta x)\) into the actuator. The small-signal supply voltage is zero, so \(\delta v=-R i\). Eliminating current gives

\[\delta v=-\frac{V C'}C\frac{i\omega\tau}{1+i\omega\tau}\delta x,\]
\[\tau=RC .\]

Linearise \(F_e=V^2 C'/2\) allowing both voltage and position to vary. The direct derivative is \(K_{e0}=V^2C''/2\), while the change from node voltage is \(VC'\,\delta v\). For an ideal parallel plate \(C''/2=(C')^2/C\), so the two terms combine to the simple complex relation \(\delta F_e=K_{e0}\delta x/(1+i\omega\tau)\). At low frequency the electrical force follows displacement with its fixed-voltage slope. At high frequency the slope vanishes, as it must for an isolated ideal plate carrying fixed charge over one oscillation. At intermediate frequency a motion-induced current dissipates heat in the resistor.

Bring \(\delta F_e\) to the left side of the mechanical equation. Its real part subtracts \(K_{e0}/[1+(\omega\tau)^2]\) from the mechanical stiffness; its imaginary part adds \(K_{e0}\tau/[1+(\omega\tau)^2]\) to the viscous damping coefficient. This damping is positive for a passive resistor. At \(s=0.20\) the static electrical stiffness is \(1.00\) N/m, the operating capacitance is 55.3 fF and \(R=400\) MΩ gives

\[\tau=22.1\,\mu\mathrm s.\]

A 7.2 kHz interrogation has \(\omega\tau\simeq1\). Only about half the static electrical slope survives and the added damping is roughly \(11\,\mu\mathrm{N\,s/m}\). Treat these as frequency-dependent coefficients in the driven susceptibility. Substituting the low-frequency stiffness into a ringdown fit at this frequency would give the wrong displacement when the fitted frequency is inverted. Fitting the complex response at several frequencies avoids that ambiguity.

An experiment can separate the circuit effect from mechanical nonlinearity. Keep the same static bias and displacement, insert two known series resistances, then measure both in-phase and quadrature response to a small sinusoidal force. The displaced equilibrium should remain essentially unchanged at dc if leakage stays small. A stiffness dispersion and dissipative peak that shift in proportion to \(1/R\) support an electrical cause. Then repeat at a smaller oscillation amplitude. Amplitude-dependent frequency shift that survives the change in resistance can arise from nonlinear spring or force curvature, which the first-order susceptibility leaves out. A simple change to the external circuit has turned the slope of an energy curve into a prediction for a measured phase lag.

Compare force intersections for voltage and charge control

The initial gap is 2.00 μm, the area is a 100 μm square and the mass is 0.50 μg. Use the voltage ratio to move the force curve through the fold. At 93% of pull-in the low-displacement fixed-voltage intersection has a positive restoring slope. The high-displacement intersection has a negative slope. The charge-controlled line is prepared at the selected voltage at the original open gap. It gives the same initial force but a different subsequent curve. The readout reports both open-gap roots even if the upper root lies beyond the plotted interval. At the baseline stiffness, static pull-in is 7.32 V.

Change the spring stiffness while holding the voltage ratio fixed. The dimensionless locations of the roots stay in place, but their dimensional force and small-signal frequency change. This checks the scaling that eliminated the physical dimensions in the fold equation. Then set the ratio between the dynamic step threshold and unity. Use the force intersections to locate the potential maximum and sketch the area between attraction and spring reaction from the initial position. Its signed integral supplies the work which distinguishes a bounded excursion from crossing the maximum. The displayed curves predict initial-value behaviour only when combined with a choice of initial kinetic energy and damping.

Tutorial · distinguish stability from force balance

Infer a gap fraction and a bias from a resonance

An otherwise identical actuator shows \(f/f_0=0.80\) at a stable fixed voltage. Find the deflection as a fraction of gap, the voltage relative to pull-in, and the independent capacitance change. What could spoil this comparison?

Work through the solution

Here \(r=0.64\) and \(s=(1-0.64)/(3-0.64)=0.1525\). The bias ratio is \(\sqrt{(27/4)s(1-s)^2}=0.860\) approximately. The parallel-plate capacitance should rise by \(1/(1-s)-1=18.0\%\). Measure the change relative to the active capacitance after removing any constant wiring capacitance. Disagreement can come from changing mode shape, a nonlinear spring, a tilted plate, a measurement frequency above the electrical equilibration bandwidth, or an incorrect extraction of mechanical stiffness from a strongly damped resonance. With a measured gap and mode shape these explanations yield different quantitative corrections.

Choose a series capacitor to move the static fold

The original 44.3 fF zero-bias actuator should remain on its stable slope as far as \(x=0.60g\), ignoring contact and other limits. Find the series capacitance whose fold falls exactly at this displacement. How much supply voltage appears across the actuator at that point?

Work through the solution

Set \(g_e/3=0.60g\), giving \(\epsilon A/C_s=0.80g\) and \(C_s=C(0)/0.80=55.4\) fF. At \(0.60g\) the actuator capacitance is \(C(0)/0.40=110.7\) fF. Series charge is identical in both capacitors, so

\[V_{\rm act}/V_{\rm supply}=C_s/(C_s+C_{\rm act})=1/3.\]

Choosing exactly this value places operation at vanishing ideal stiffness, so a strictly positive measured restoring slope at that displacement requires a smaller series capacitance or a different margin. The result is sensitive to additional capacitance connected between the series node and ground.