Fundamentals / Physics / Condensed matter and band theory / Structure, excitations and probes of solids

Measure a phonon mean free path without confusing it with a sample length

A cold insulating bar can carry heat primarily through lattice vibrations. Heat capacity tells how much energy the vibrations can carry; conductivity also depends on how far and in which direction they carry it. Derive the connection, test its limiting regimes, and identify when a measured thermal resistance belongs to a boundary.

Derive the kinetic expression from a displaced occupation

Consider phonon modes labelled by wavevector \(\mathbf k\) and branch \(s\), with angular frequency \(\omega_{\mathbf k s}\) and group velocity \(\mathbf v_{\mathbf k s}=\nabla_{\mathbf k}\omega_{\mathbf k s}\). A mode transports energy \(\hbar\omega\) per quantum. At equilibrium states with opposite velocities cancel in the heat current. A small slowly varying temperature gradient perturbs the Bose occupation \(n_0(T)\). In the relaxation-time approximation the stationary transport equation is

\[\mathbf v\cdot\nabla T\,\partial_Tn_0=-\delta n/\tau.\]

This describes weak near-equilibrium transport when a mode can be assigned a characteristic relaxation time.

Insert the correction into the heat current density \(\mathbf j_Q=V^{-1}\sum\hbar\omega\,\mathbf v\,\delta n\). Comparing with \(j_{Q,i}=-\kappa_{ij}\partial_jT\) gives

\[\kappa_{ij}=V^{-1}\sum c_{\mathbf k s}v_i v_j\tau_{\mathbf k s},\]

where \(c_{\mathbf k s}=\hbar\omega\,\partial_T n_0\) is the heat capacity contribution of one mode. In an isotropic solid the angular average of \(v_x^2\) is \(v^2/3\). An effective common speed and path \(\ell=v\tau\) then yield \(\kappa\simeq C_Vv\ell/3\) for heat capacity per volume \(C_V\). The factor one third counts directional projection, not the three separate phonon branches.

Connect the Debye heat capacity to low-temperature transport

For a three-dimensional isotropic acoustic branch with \(\omega=v_s k\), the number of states in a wavevector shell is proportional to \(k^2 dk\). Thus its density of states per volume is proportional to \(\omega^2/v_s^3\). In the thermal energy \(\int d\omega\,g(\omega)\hbar\omega/(e^{\hbar\omega/k_BT}-1)\), substitution \(x=\hbar\omega/k_BT\) produces a factor \(T^4\) when occupied frequencies remain below the high-frequency cutoff. Differentiation gives

\[C_V\propto T^3.\]

Different sound speeds of longitudinal and transverse branches enter the coefficient. An optical mode with a nonzero minimum frequency contributes much less at sufficiently low temperature.

If rough sample boundaries dominate scattering and give an approximately temperature-independent mean path, the kinetic expression predicts \(\kappa\propto T^3\). A more specular boundary can increase the effective path of long-wavelength modes and modify that exponent. Conversely once many modes are thermally populated, heat capacity tends toward saturation and increasing phonon–phonon or defect scattering can reduce conductivity. Adding rates as \(1/\tau=1/\tau_{\rm b}+1/\tau_{\rm defect}+1/\tau_{\rm anh}\) assumes independent effective relaxation mechanisms. Normal phonon collisions conserve crystal momentum and do not always relax heat current as efficiently as a naive single-rate sum implies.

Take an insulating crystal at one temperature with measured \(C_V=40\,{\rm J/(m^3K)}\), representative \(v=4000\,{\rm m/s}\), and \(\kappa=0.80\,{\rm W/(mK)}\). The inferred effective path is \(3\kappa/(C_Vv)=15\,\mu{\rm m}\), corresponding to \(3.75\,{\rm ns}\). In a \(1.0\,{\rm mm}\)-wide specimen this is much shorter than its width. An assertion that only diffuse sidewall collisions limit transport would need further evidence. Measuring a second transverse dimension and checking whether the inferred path scales with it is more discriminating than matching a single temperature exponent.

Background · Which temperature does a finite-gradient measurement report?

Suppose the conductivity obeys \(\kappa(T)=bT^3\) across a homogeneous bar with a diffusive local temperature field. In a steady state the heat flux is uniform. Integrating Fourier's law shows that dividing the heat flux times length by the end-to-end temperature difference returns the temperature average of \(\kappa\). Let \(T_m\) be the arithmetic mean and \(\Delta T=T_h-T_c\).

\[\kappa_{\rm app}=\frac{1}{\Delta T}\int_{T_c}^{T_h}bT^3\,dT=bT_m^3\!\left(1+\frac{\Delta T^2}{4T_m^2}\right).\]

A 1 K drop centred on 2 K raises the apparent conductivity by 6.25% relative to the local value at 2 K. Halving the temperature difference reduces the excess by a factor of four. That dependence gives an experimental check before attributing a deviation to boundary scattering.

Distinguish sample conductivity from contact and ballistic resistance

A steady one-dimensional bar of area \(A\) and length \(L\) carries power \(P=\kappa A\Delta T_{\rm bulk}/L\) in the diffusive regime. If the two contacts have thermal resistances \(R_1,R_2\), an externally measured temperature difference gives

\[R_{\rm tot}=\Delta T/P=R_1+R_2+L/(\kappa A).\]

A plot of total resistance against length for otherwise equivalent specimens can separate intercept from bulk slope. A contact-limited device fitted as pure bulk appears to have a length-dependent conductivity. At very small lengths, ballistic transport itself supplies a length-independent resistance, which a length sweep alone cannot always distinguish from ordinary contacts.

For area \(A=1.0\,{\rm mm^2}\), suppose resistance rises from \(3600\,{\rm K/W}\) for a \(2.0\,{\rm mm}\) bar to \(8600\,{\rm K/W}\) for a \(6.0\,{\rm mm}\) bar under matched contacts. The slope gives \(\kappa=0.800\,{\rm W/(mK)}\) and the intercept \(1100\,{\rm K/W}\). At \(P=20\,\mu{\rm W}\) the shorter device has an external temperature difference \(0.072\,{\rm K}\), of which \(0.022\,{\rm K}\) is attributable to the contacts. Failing to subtract the intercept gives an apparent conductivity only \(0.556\,{\rm W/(mK)}\). Temperature probes located inside the bar can measure the bulk gradient more directly.

When the path is comparable to a sample dimension the local Fourier relation with one well-defined temperature per point needs justification. In a simple isotropic ballistic picture a reservoir emits an energy flux on one side with angular factor \(1/4\), leading to a conductance per area of order \(C_Vv/4\) for perfectly transmitting contacts. This differs from the \(1/3\) in the diffusive expression; the angular integrals describe different boundary-value problems. A finite transmission probability, mode mismatch and partial equilibration near reservoirs can further reduce conductance. A stated mean free path inferred using Fourier's law beyond this crossover is an effective fit, not an independently measured microscopic length.

Estimate when a heater measurement leaves linear response

A cold crystal can have a temperature-dependent conductivity over even a small absolute thermometer difference. In a uniform bar at steady state, constant heat current obeys \(P L/A=\int_{T_c}^{T_h}\kappa(T)\,dT\). If \(\kappa=\beta T^3\), then \(P=\beta A(T_h^4-T_c^4)/(4L)\). Dividing measured flux by a nominal gradient gives the interval average of conductivity, rather than its exact value at either thermometer temperature. For \(T_c=2\,{\rm K},T_h=4\,{\rm K}\), the averaged conductivity is \(30\beta\), whereas \(\kappa\) at the mean temperature \(3\,{\rm K}\) is \(27\beta\). The eleven-percent difference is a consequence of nonlinear temperature dependence, even with perfect contacts and sensors.

Shrink the heater excursion at the same mean temperature to test the small-gradient approximation. A contact bottleneck can itself become nonlinear, in which case subtracting a constant contact resistance found at a different mean temperature is also inappropriate. Modulate a small heating power around a stable bias and analyse the differential thermal resistance, or measure temperatures at internal probes for several heat currents. These protocols probe a particular operating point and can distinguish the curvature of the intrinsic material response from the curvature of the two contact heat-transfer laws.

Tutorial on a thermal measurement

A bar with boundary-limited \(C_V\propto T^3\) is cooled from 4 K to 2 K with unchanged diffuse boundary path. How should its thermal conductivity and its diffusivity change?

Work through the solution

Conductivity falls by a factor eight. Thermal diffusivity \(\kappa/C_V\simeq v\ell/3\) stays approximately constant. An experiment measuring the relaxation time of a spatial sinusoidal temperature disturbance probes diffusivity, while a steady gradient at given heat flux probes conductivity. The two measurements need not have the same temperature dependence.

Using the worked \(15\,\mu{\rm m}\) path, predict the thermal diffusivity and the decay time of a long-wavelength sinusoidal temperature modulation with wavelength \(1.0\,{\rm mm}\).

Work through the solution

The diffusivity is

\[0.80/40=0.020\,{\rm m^2/s}.\]

The diffusive decay time is

\[1/[D_T(2\pi/\lambda)^2]=1.27\,\mu{\rm s}.\]

Here \(k\ell\approx0.094\), reasonably small. At a wavelength comparable to the inferred path a diffusive exponential should be tested rather than assumed.

A sample's conductivity increases after isotopic purification while its measured heat capacity hardly changes. What microscopic inference is supported?

Work through the solution

In the kinetic picture similar heat capacity and sound speed leave a longer weighted phonon path as the natural interpretation. Isotope disorder can scatter vibrations while leaving the gross mode count similar. Check geometric dimensions and contact resistances before attributing the full change to bulk scattering. A mean path deduced this way is weighted by mode heat capacities and velocities, not a single universal length for every phonon.

David Tong counts acoustic and optical phonons and derives their thermodynamics.

Compare lattice heat flow with heat carried by electronic excitations.