Fundamentals / Physics / Condensed matter and band theory

Counting carriers and weighing a cyclotron orbit

A conical band has no constant quadratic band mass at its touching point. A carrier on a finite-energy orbit still has a measurable cyclotron mass. Counting states fixes the Fermi circle and determines how this mass changes when a gate adds charge.

Count states in a two-dimensional disc

Put a two-dimensional sheet of area \(A=L_xL_y\) under periodic boundary conditions. Neighbouring allowed wavevectors differ by \(2\pi/L_x\) and \(2\pi/L_y\), so each state occupies reciprocal-space area \((2\pi)^2/A\). At zero temperature fill all conduction states up to radius \(k_F\), measured from a Dirac point. There are two spin states and two inequivalent valleys in ideal monolayer graphene, giving total degeneracy \(g=4\). Density relative to charge neutrality is therefore

\[n=g\frac{\pi k_F^2}{(2\pi)^2}=\frac{k_F^2}{\pi},\]
\[E_F=\hbar v_F\sqrt{\pi n}.\]

For electron and hole densities use \(|n|\) under the square root and give \(E_F\) the sign of \(n\) relative to the touching point. Differentiating the state count with respect to energy gives the density of states per area \(D(E)=g|E|/[2\pi(\hbar v_F)^2]\). It tends to zero at an ideal neutral cone. Thermal broadening, disorder and a gap all change what a finite-resolution probe observes near neutrality.

Background · Cyclotron mass
\[m_c=(\hbar^2/2\pi)\,\partial A/\partial E\]

The area is that of a closed constant-energy orbit in reciprocal space normal to the magnetic field. This is a measured orbital mass rather than a universal free-particle parameter.

Let a perpendicular field bend the orbit

For a wavepacket in a band with weak magnetic field,

\[\hbar\dot{\boldsymbol k}=-e\,\boldsymbol v\times\boldsymbol B,\]

where \(e\) denotes the positive elementary charge. An isotropic band has velocity normal to a circular constant-energy contour. The orbit is traversed with speed \(|\dot{\boldsymbol k}|=e v_F B/\hbar\). Dividing its circumference \(2\pi k_F\) by that speed gives the period. Express its angular frequency as \(eB/m_c\) to identify

\[m_c=\frac{\hbar k_F}{v_F}=\frac{|E_F|}{v_F^2}.\]

The mass measures the time needed to travel around a contour. It depends on the radius even when the magnitude of the group velocity stays fixed. For a general band area \(\mathcal A(E)\), neighbouring contours separated perpendicular to themselves by \(dk_\perp\) differ in energy by \(\hbar v\,dk_\perp\). Thus \(|d\mathcal A/dE|=\oint dl/(\hbar v)\), which gives \(m_c=\hbar^2|d\mathcal A/dE|/(2\pi)\) by integrating the same equation of motion.

Convert a gate density into an energy and a mass

At \(n=10^{12}\,\mathrm{cm^{-2}}=10^{16}\,\mathrm{m^{-2}}\) and \(v_F=10^6\,\mathrm{m/s}\), one obtains \(k_F=1.772\times10^8\,\mathrm{m^{-1}}\), \(E_F=0.117\,\mathrm{eV}\) and \(m_c=1.87\times10^{-32}\,\mathrm{kg}=0.0205m_e\). Quadrupling the density doubles the Fermi energy and cyclotron mass. By contrast a single isotropic parabolic band \(E=\hbar^2 k^2/(2m)\) has the same counting geometry but constant \(m_c=m\). Transport mobility or disorder scattering time does not enter the state count, although scattering can obscure the cyclotron motion.

Change velocity and signed density. Raising the velocity at fixed density increases \(|E_F|\) while reducing the mass because the orbit radius stays fixed and the wavepacket moves faster. Exactly at charge neutrality, a single classical Fermi orbit no longer describes the carriers. Finite-field quantum levels replace the continuum picture in the next chapter.

Tutorial on a density sweep

Two cyclotron measurements on the same gapless sheet return masses \(0.024m_e\) and \(0.036m_e\). Assume the velocity is independent of density. Infer the ratio of absolute carrier densities and the change in the weak-field cyclotron frequency at fixed field.

Work through the solution

Since \(m_c\) scales as \(\sqrt{|n|}\), the second density is \((0.036/0.024)^2=2.25\) times the first. The frequency \(eB/m_c\) drops to two thirds of its first value. The masses alone cannot reveal whether either measurement used electrons or holes.

Find the weak-field cyclotron radius at the worked density \(10^{12}\,\mathrm{cm}^{-2}\) and field \(0.10\,\mathrm T\). How does raising the velocity at fixed density affect it?

Work through the solution

The semiclassical radius is

\[r_c=v_Fm_c/(eB)=\hbar k_F/(eB).\]

With \(k_F=1.772\times10^8\,\mathrm{m}^{-1}\),

\[r_c=1.17\,\mu\mathrm m.\]

At fixed density and field the radius stays fixed when velocity changes. The orbit period changes because the speed around that circle changes.

A measurement doubles positive \(E_F\) at constant temperature sufficiently close to zero for the step filling approximation. How do state density per area and density of states per energy change?

Work through the solution

For fixed \(v_F\), the occupied density scales as \(E_F^2\), so it rises fourfold. The derivative \(D(E_F)\) scales as \(|E_F|\) and doubles. Confusing the count with its derivative would give the wrong charge change inferred from spectroscopy.

Further reading · Novoselov and colleagues, measured energy dependence of the cyclotron mass.