Fundamentals / Physics / Classical mechanics / Mechanics in the laboratory

Measure gravity with a pendulum of finite amplitude

A metre-long pendulum is an appealing clock because its small-angle period depends only on length and gravity. A precise clock can nevertheless give a precisely wrong value of gravity. Derive the full period, trace the systematic error to an identifiable approximation and design a measurement that distinguishes a length error from a release-angle error.

Define the measured length and time

Use a point bob on a massless, inextensible string attached to a fixed pivot. Let \(L\) be the distance from pivot to the bob's centre of mass, and \(\theta\) the signed departure from the downward vertical. For a rigid extended bob, rotational inertia about its own centre adds to \(mL^2\); a length measured to the bottom of the bob is neither of these dynamical lengths. Measure the elapsed time between successive crossings of a photogate in the same direction. Crossings in opposite directions give half of the period in a symmetric oscillation. A stationary turning point is a poor timing marker because the position error there produces a large time error.

At rest at the release angle \(\theta_0\), the energy is \(mgL(1-\cos\theta_0)\). At a later angle the speed is \(L|\dot\theta|\). Equating kinetic plus potential energy to the release value gives

\[\dot\theta^2=(2g/L)(\cos\theta-\cos\theta_0).\]

Only a quarter cycle is needed. Inverting the angular speed and integrating from zero to \(\theta_0\) produces a square-root singularity at release. The period is finite since integrating the inverse square root over a small interval gives a square root.

Resolve the turning point before approximating

Write \(k=\sin(\theta_0/2)\) and substitute \(\sin(\theta/2)=k\sin u\). The vanishing square root cancels a factor \(\cos u\) from the differential. One obtains the complete elliptic integral of the first kind with modulus \(k\).

\[T=4\sqrt{\frac Lg}\,K(k),\]
\[K(k)=\int_0^{\pi/2}\frac{du}{\sqrt{1-k^2\sin^2u}}.\]

Expanding its integrand yields

\[K(k)=(\pi/2)(1+k^2/4+9k^4/64+\cdots).\]

Since \(k\simeq\theta_0/2\) at small amplitude, the first fractional period correction is \(\theta_0^2/16\) with angle in radians. It is positive. At larger amplitude the tangential component of gravity rises more slowly with angle than the linear restoring law predicts. The pendulum spends longer near the turns. Passing degrees directly into the quadratic correction would give nonsense even if the timer and recorded angle were perfect.

Infer the bias in gravity

Suppose the true acceleration is \(9.81\,\mathrm{m\,s^{-2}}\), the length is 1.000 m and the release angle is 30 degrees. The small-angle period is about 2.0061 s and the finite-amplitude period about 2.0410 s. Interpreting the longer measured period by the linear formula would give about \(9.48\,\mathrm{m\,s^{-2}}\). The fractional gravity error is about twice the fractional period error with opposite sign because gravity is inferred from \(T^{-2}\). Timing a hundred periods reduces random timing error but leaves this systematic shift.

The numerical curve evaluates the complete elliptic integral. It uses the arithmetic–geometric mean identity \(K(k)=\pi/[2\,\mathrm{AGM}(1,\sqrt{1-k^2})]\), so no sampled point sits on the turning point. The single-correction curve truncates the amplitude series after its first nonconstant term. Vary angle and length, comparing both the predicted period and the result a linear analysis would infer. Which change rescales both period curves together? Which changes their relative discrepancy?

Design a two-release check

For the same pendulum the ratio \(T(\theta_a)/T(\theta_b)=K(k_a)/K(k_b)\) cancels the unknown length and local gravity. Measure at two amplitudes before deciding whether to recalibrate the length. If the ratio agrees but both absolute times differ from prediction, check the effective length, clock rate and model of the bob. If the ratio changes during a decaying swing, record initial and final amplitudes for the timed sequence. The period associated with a long sequence is an average over its slowly changing amplitude. Substituting the initial angle throughout would overcorrect the measurement.

Tutorial

At small amplitude, what release angle gives a fractional period bias of approximately one part in a thousand?

Work through the solution

Set \(\theta_0^2/16=0.001\). This gives \(0.1265\) rad, about 7.25 degrees. The gravity bias from an uncorrected measurement would be approximately two parts in a thousand. A tolerance on one quantity is not automatically the same tolerance on the other.

A photogate records successive interruptions every 1.02 seconds for the metre pendulum. A calculation gives nearly four times local gravity. Identify one possible error in the observable.

Work through the solution

The gate may have counted both directions and returned a half period. Doubling that interval gives about 2.04 s. Because the inferred acceleration is inversely proportional to the square of the period, the missing factor of two gives a factor of four.

Why does reducing the grid spacing in an integration of the linear equation fail to recover the finite-amplitude curve?

Work through the solution

Integration error vanishes as the step is refined, but the restoring torque in that equation is \(mgL\theta\). The true torque is \(mgL\sin\theta\). A converged numerical solution can therefore provide independent evidence of an inadequate physical approximation.

For the equation of motion, phase portrait and dissipation, see the MIT treatment of the simple pendulum.