Fundamentals / Mechanical engineering / Machine elements and contact mechanics

Preload, joint stiffness and separation

Compute how a tensile service load changes bolt force and clamp force, and determine when a closed-joint calculation ceases to apply.

From first principles

Derive bolt and clamp increments from compatible deformation

A tightened bolt stretches while the clamped members compress. Before external loading their force magnitudes equal the preload \(F_i\). Apply a separating load \(P\) and assume both components respond elastically and the interfaces stay closed. A small opening displacement \(\delta\) stretches the bolt additionally and relieves the members by the same displacement. With stiffnesses \(k_b,k_m\) the increments are

\[\Delta F_b=k_b\delta,\]
\[-\Delta F_m=k_m\delta,\]
\[P=\Delta F_b-\Delta F_m=(k_b+k_m)\delta .\]

Here member force \(F_m\) is positive in compression. Eliminate the displacement to find both service forces and the fraction \(C\) of external load reaching the bolt.

\[C=\frac{k_b}{k_b+k_m},\]
\[F_b=F_i+CP,\]
\[F_m=F_i-(1-C)P .\]

Setting \(F_m=0\) predicts incipient separation at \(P=F_i/(1-C)\). Once the interface can no longer supply compressive reaction, the closed-joint stiffness partition ceases to describe the load path. The derivation explains why service bolt tension grows by only a fraction of applied load before separation.

Background · Joint stiffness fraction
\[C=k_b/(k_b+k_m)\]

Before separation, bolt and clamped-member stiffnesses decide what fraction of a separating external force increases the bolt load.

Derivation and applications

Predict preload loss caused by settlement of a bolted joint

A tightened joint may lose clamp load before it sees any external service force. Model the bolt by axial stiffness \(k_b\) and the compressed members by stiffness \(k_m\). Assume elastic incremental behaviour, closed contact, fixed temperature and a nut that does not rotate after tightening. Initial preload \(F_i\) stretches the bolt and compresses the members. A small permanent settlement \(s\) at asperities or interfaces consumes part of the initial imposed interference.

\[\Delta_{\rm installed}=F_i\left(\frac1{k_b}+\frac1{k_m}\right),\]
\[\Delta_{\rm remaining}=\Delta_{\rm installed}-s .\]

The same preload passes through the bolt and compressed stack before an external tensile load is applied. Recovering their combined elastic displacement therefore reduces the preload according to their series stiffness. The result applies as long as positive clamp load remains.

\[F_r=F_i-k_{\rm eq}s,\]
\[k_{\rm eq}=\left(\frac1{k_b}+\frac1{k_m}\right)^{-1}.\]

Now apply an external separating force \(P\). In a closed joint the bolt takes fraction \(C=k_b/(k_b+k_m)\) of that force and the clamp decreases by \((1-C)P\). Setting the residual clamp to zero gives the revised separation threshold.

\[F_{\rm clamp}=F_r-(1-C)P,\]
\[P_{\rm sep}=\frac{F_i-k_{\rm eq}s}{1-C}.\]

Settlement is a displacement, so a more compliant bolt can reduce the preload lost per micrometre. Other design constraints, including stiffness, load introduction and fatigue, remain relevant when altering bolt geometry.

Worked example

Audit a joint after a measured bedding-in displacement

Let \(k_b=200\) kN/mm, \(k_m=800\) kN/mm and \(F_i=24.0\) kN. The series stiffness is 160 kN/mm. A settlement of 15.0 µm reduces preload by \(160(0.0150)=2.40\) kN, leaving 21.6 kN. Since \(C=0.200\), the new separation load is 27.0 kN. Before settlement it would have been 30.0 kN.

Change the inputs and inspect this calculation below

Second application

Find an allowable settlement from a service condition

A separate joint has \(k_b=120\) kN/mm, \(k_m=360\) kN/mm and initial preload 18.0 kN. At maximum separating force 12.0 kN it must retain 5.00 kN clamp. The required residual preload is

\[5.00+0.750(12.0)=14.0\,\mathrm{kN}.\]

The allowable preload loss is 4.00 kN and \(k_{\rm eq}=90.0\) kN/mm, yielding \(s_{\max}=0.0444\) mm. The stated requirement is more restrictive than merely keeping contact closed.

Interactive calculation · Change the inputs of this example

Use the adjustable quantities to test the two worked calculations above. The plot recomputes this derivation’s balance or constitutive relation; its numerical readout reports the quantities needed for the forward calculation and the inverse or design question. Keep the fixed assumptions stated in the readout when comparing with the example values.

Establish the state before the external load arrives

A tensioned bolt in an assembled flange has already elongated. The material clamped between head and nut has already shortened. In the ideal concentric joint these initial forces have equal magnitude \(F_i\), as a free-body diagram of either flange shows. Tightening stores elastic energy in both parts. Calling a joint unloaded usually means that the external service load is zero. The thread root can still carry a significant tensile stress.

Represent the effective bolt grip by a tensile spring \(k_b\) and the compressed members by a spring \(k_m\). For a uniform segment the axial stiffness is \(EA/L\); threaded and plain segments in series have added compliances. The member stiffness depends on the path through which compressive force spreads from the head and washer. A thin flexible flange may also bend. For this derivation consider one bolt, an axial load introduced at the outside faces and no eccentricity or prying. Let clamp force denote a positive magnitude in compression.

Background · How does a small loss of grip thickness reduce preload?

Surface roughness can flatten under load after tightening. Suppose this reduces the unloaded thickness of the clamped stack by \(s\) while the nut stays on the same thread position. The recovered bolt elongation and the elastic recovery of the clamped members must together accommodate that lost thickness.

\[s=\Delta F\left(\frac1{k_b}+\frac1{k_m}\right),\]
\[\Delta F=\frac{k_bk_m}{k_b+k_m}\,s.\]

With bolt stiffness 200 kN/mm, member stiffness 800 kN/mm and settlement 0.010 mm, preload falls by 1.6 kN. This estimate assumes the stack is still in compression and both springs retain their tangent stiffness. A longer, more compliant bolt loses less preload for the same settlement because a given length change produces a smaller force change.

Apply compatibility to the load increment

An external separating force \(P\) allows the bolt to extend a little while the clamped members recover some of their initial compression. As long as the faces remain in contact, the extension and recovery have the same magnitude \(x\). The bolt-force increase is \(k_bx\) and the clamp-force decrease is \(k_mx\). Force equilibrium across the joint gives

\[P=F_b-F_m=(k_b+k_m)x.\]

Eliminate \(x\) and introduce the load fraction \(C\).

\[C=\frac{k_b}{k_b+k_m},\]
\[F_b=F_i+CP,\]
\[F_m=F_i-(1-C)P.\]

The slopes of bolt force and clamp-force magnitude have opposite signs. The joint opens in this ideal model when \(F_m\) reaches zero, at \(P_{\rm sep}=F_i/(1-C)\). Continuing the same line beyond that point would predict tension between unbonded faces. Once open, the bolt must carry the full external tensile force and the load slope changes to unity. Both expressions give the same bolt force at the instant of separation.

Check a service cycle and a separate overload

Take \(k_b=180\,\mathrm{kN/mm}\), \(k_m=720\,\mathrm{kN/mm}\), \(F_i=25\,\mathrm{kN}\) and bolt tensile stress area \(A_t=58.0\,\mathrm{mm^2}\). A pressure pulsation creates a separating force cycling between 4 and 16 kN. Here \(C=0.20\), hence bolt force ranges from 25.8 to 28.2 kN. Clamp force falls from 21.8 to 12.2 kN and remains positive. The bolt’s alternating tensile stress is the force range divided by twice its tensile stress area.

\[\sigma_a=(28.2-25.8)10^3/(2\times58.0)=20.7\,\mathrm{MPa}.\]

At the maximum ordinary load the calculated tensile stress is 486 MPa. If the specified proof stress is 600 MPa, the axial proof-load benchmark is \(600(58.0)=34.8\,\mathrm{kN}\). The estimated separation threshold is

\[25/0.8=31.25\,\mathrm{kN}.\]

A singular tensile overload of 34 kN opens the interface and brings the bolt to 34 kN, just below the supplied axial proof benchmark. It can nevertheless break the seal at the flange face. Different requirements can control the same event.

Bolt tension rises slowly while clamp force falls to zero, then the bolt carries the whole external tension.
For a load-sharing factor of 0.20 the joint opens at 1.25 times its initial preload. The slope of bolt force against external force changes at separation.

Use attainable preload, including its scatter

Increasing preload by 3 kN raises both initial forces and delays separation by \(3/(1-C)=3.75\,\mathrm{kN}\). It also raises the peak bolt stress by \(3000/58=51.7\,\mathrm{MPa}\) throughout the closed regime. Reducing bolt stiffness relative to the members can lower the alternating force. For example a longer effective grip can increase bolt compliance. Recheck the residual clamp and separation conditions whenever changing stiffness.

If tightening produces a range of preloads, assess separation with the low end and proof stress with the high end. An assembly tolerance of ±3 kN around the nominal value gives a minimum separation threshold of \(22/0.8=27.5\,\mathrm{kN}\). The largest ordinary bolt force would be \(28+0.2(16)=31.2\,\mathrm{kN}\). The preload scatter enters these checks even though the external service force is perfectly known. In a real flange, surface settling, differential thermal expansion and off-axis loading can change the available clamp force after assembly.

Resolve tightening torque into thread lift and friction

Joint preload depends on the tightening method as well as bolt and flange stiffness. For an elementary torque estimate, unwrap one turn of the thread at pitch diameter \(d_2\). Its lead \(l\) over the circumferential distance \(\pi d_2\) defines helix angle \(\lambda=\arctan[l/(\pi d_2)]\). For a square thread lifting axial load \(F_i\), resolving an applied tangential force and Coulomb friction on the incline gives

\[F_{\rm tan}=F_i\tan(\lambda+\phi),\]

where \(\tan\phi=\mu_t\). For a symmetric V-thread of half-angle \(\alpha\), a common small-helix approximation increases the effective friction to \(\mu_t/\cos\alpha\) because the flanks carry a larger normal force.

Under the head or nut, sliding friction at effective radius \(r_b\) adds torque \(\mu_b F_i r_b\). A simple total tightening estimate is

\[T\simeq F_i[(d_2/2)\tan(\lambda+\arctan(\mu_t/\cos\alpha))+\mu_b r_b].\]

The first term includes ideal screw lift and thread friction; the second is bearing-face friction. In the limit of zero friction the thread term reduces to \(F_i l/(2\pi)\), as verified by equating work over one revolution to axial load times lead. This lower bound also shows why most measured tightening torque can disappear into friction rather than useful bolt elongation. Effective bearing radius depends on contact geometry and pressure distribution, and the coefficients may differ between production lots.

Determine preload sensitivity to lubrication at fixed torque

Use an illustrative single-start thread with \(d_2=9.0\) mm, \(l=1.50\) mm, flank half-angle 30° and effective bearing radius 7.0 mm. The helix angle is

\[\arctan[1.5/(\pi9)]=3.04^\circ.\]

With \(\mu_t=\mu_b=0.15\), the effective thread friction angle is 9.83°. The thread torque arm is \(4.5\tan(12.87^\circ)=1.03\,\mathrm{mm}\), and bearing friction contributes another 1.05 mm. A tightening torque of 40 N m therefore suggests \(F_i=40000/(1.03+1.05)=19.2\,\mathrm{kN}\). The frictionless lift portion would be only \(19.2(1.50)/(2\pi)=4.59\,\mathrm{N\,m}\).

If lubrication reduces both coefficients to 0.08 at the same applied torque, the effective thread friction angle becomes 5.28°. The torque arms are now \(4.5\tan(8.32^\circ)=0.658\) mm and 0.560 mm. Implied preload rises to

\[40000/1.218=32.8\,\mathrm{kN}.\]

A tensile area of 58 mm² would then carry about 566 MPa before the service force arrived, compared with 331 MPa originally. An old torque setting may therefore raise preload substantially after a change of coating or lubricant. A direct elongation measurement can help distinguish this friction change from loss of clamp due to settling, although the effective bolt grip and modulus must also be known.

The axial stretch provides an independent expected signal. Suppose the effective uniform tensile length is 50 mm with \(E=210\,\mathrm{GPa}\) and area 58 mm². The two preload estimates imply elastic elongations \(F_iL/(EA)=0.079\) and 0.135 mm. An instrument resolving about 0.01 mm could distinguish the two states in this example if its gauge length includes the correctly modelled bolt segments. Thread and shank regions of different areas contribute as elements in series. A clamp-force reading taken after surfaces have settled can also differ from a tightening-time elongation record without a change in friction coefficient.

Interactive calculation · Change the inputs of this example

Change the parameters of this reference plot and compare its limiting cases. The fixed illustration remains beside the derivation; the adjustable calculation exposes the same dependence on geometry, material properties or loading.