From first principles
Build a transient response by accumulating elementary impulses
An impulse \(J\) is the time integral of applied force. Across an ideal instantaneous impulse the displacement of mass \(m\) stays continuous, while integrating Newton's law gives a velocity jump \(J/m\). Finite spring and viscous forces have vanishing impulse over that ideal interval. For an initially stationary undamped mount with stiffness \(k\), the following motion is free vibration with angular frequency \(\omega_n=\sqrt{k/m}\) and the new initial velocity.
Now divide a finite force trace into short intervals. The interval starting at \(s\) contributes impulse \(F(s)\,ds\). For a linear time-invariant system its later displacement is the impulse solution delayed by \(s\) and scaled by that impulse. Summing over all earlier intervals yields
An existing initial displacement or velocity contributes a separate free response by superposition. If the pulse is very short relative to the vibration period, the sine factor changes little during it and the area of the pulse controls the subsequent motion.
Derivation and applications
Obtain the residual vibration after a ramped force is removed
The time integral of a force sets momentum change only when the support forces have little time to act. For longer pulses a linear undamped oscillator retains information about the shape and timing of the load. Consider mass \(m\), stiffness \(k\), natural frequency \(\omega=\sqrt{k/m}\) and zero initial motion. For a force acting only from zero to \(T\), the post-pulse displacement follows the convolution with the impulse response.
Expand the sine of the difference into sine and cosine of \(t\). The two integrals multiply quadrature components of free vibration. Their resultant magnitude is the modulus of a single Fourier integral at the natural frequency. For a symmetric triangular pulse centred at \(T/2\), its area is \(J=F_pT/2\) and its transform factorises because the triangle is a convolution of two equal rectangles of duration \(T/2\).
Each rectangle contributes the average complex phase over its duration; the product of these averages produces the squared factor. The impulse estimate is recovered for a very short triangle, while certain longer pulses leave no residual motion in the ideal model.
Worked example
Compare a triangular pulse with its impulse limit
For \(m=2.00\) kg and \(\omega=20.0\) rad/s choose \(T=\pi/10\) s and \(F_p=4.00\) N. Pulse area is 0.628 N s and the impulse estimate is 15.7 mm. Here \(\omega T/4=\pi/2\) and the squared factor is
Actual residual amplitude is 6.37 mm. The cancellation occurs because different increments of force reach different phases of the oscillator.
Change the inputs and inspect this calculation below
Second application
Design a pulse with zero residual motion
Another lightly damped test rig is idealised as undamped at 5.00 Hz. The first zero requires a symmetric triangular pulse lasting two periods, \(T=0.400\) s. To deliver impulse 0.300 N s, choose \(F_p=2J/T=1.50\) N. The mass can move during the pulse, but its final displacement and velocity are both zero in the ideal model. A measured ring-down identifies sensitivity to frequency error, damping or a distorted force shape.
Interactive calculation · Change the inputs of this example
Use the adjustable quantities to test the two worked calculations above. The plot recomputes this derivation’s balance or constitutive relation; its numerical readout reports the quantities needed for the forward calculation and the inverse or design question. Keep the fixed assumptions stated in the readout when comparing with the example values.
A short event and a long response
A latch strikes a mounted instrument for only a few milliseconds, but its motion persists after contact has ended. Peak force alone gives an incomplete description of that motion. Duration, impulse and the system’s natural time scale all matter. Define impulse \(J=\int F(t)\,dt\), with units N·s. Integrating \(m\ddot x+c\dot x+kx=F\) over an ideal instantaneous event leaves \(m[\dot x(0^+)-\dot x(0^-)]=J\). The position remains continuous since no finite mass can jump a finite distance in zero time under a finite impulse.
For an initially resting underdamped oscillator, the subsequent response follows from the two initial conditions \(x(0^+)=0\) and \(\dot x(0^+)=J/m\). With \(\alpha=c/(2m)\) and \(\omega_d=\sqrt{k/m-\alpha^2}\), the displacement is \(x=Je^{-\alpha t}\sin(\omega_dt)/(m\omega_d)\) for \(t>0\). The response to a unit impulse is the same expression with \(J=1\). Its units are displacement per unit impulse.
Build a solution from elementary impulses
Divide a general forcing record into short intervals at times \(s\). Each interval contributes impulse \(F(s)\,ds\) and creates a response delayed by \(s\). Adding all contributions in a linear time-invariant system with zero initial state produces the convolution
This construction makes causality explicit: later parts of the force record cannot influence the current response. Nonzero initial conditions add the free solution. In a multi-mode system each mode has its own impulse response, and the load’s location determines the force projection into it. Replacing the structure by its first mode may describe long-wave displacement well while missing a short, local acceleration peak.
Work a pulse of known duration
Neglect damping and apply constant force \(F_0\) for \(0<t<t_p\). During the pulse integration gives
After unloading the mass oscillates freely. Compute its amplitude from the end displacement and velocity:
Let \(m=4.0\) kg, \(k=1600\) N/m, \(F_0=20\) N and \(t_p=0.050\) s. Then \(\omega_n=20\) rad/s and the impulse is 1.0 N·s. The formula predicts \(A=25\sin(0.50)=12.0\) mm after unloading. Replacing the whole pulse by an instantaneous impulse gives
Some restoring force developed during the real pulse, so the impulse approximation is slightly high.
Find the criterion and its limitations
Divide the finite-pulse amplitude by the impulse approximation to obtain \(|\sin z/z|\) with \(z=\omega_nt_p/2\). Its small-\(z\) expansion is \(1-z^2/6+\cdots\). At fixed impulse, a sufficiently short pulse therefore gives about the same low-mode amplitude regardless of duration. A shorter event has a broader frequency content, potentially increasing the importance of higher modes.
A pulse lasting exactly one natural period gives zero residual amplitude in the ideal undamped oscillator, although the displacement during the pulse peaks at \(2F_0/k\). Checking only the post-event motion would miss that maximum. In experiments record the force and response during contact as well as after it. Damping, uncertain pulse shape or nearby modes make exact cancellation unlikely, but the example shows why pulse duration must accompany a quoted peak force.
Compare pulses of equal impulse
A force transducer may report identical total impulse for a sharp tap and a broader pulse. For an undamped mode, the amplitude after the force has ended is the modulus of its frequency-weighted impulse divided by \(m\omega_n\):
This follows by expanding the sine kernel of the convolution into two quadratures. For a rectangular pulse the ratio to the ideal instantaneous-impulse amplitude is \(|\sin(\omega_nt_p/2)/(\omega_nt_p/2)|\). At a duration equal to half the natural period that factor is
Two force records with equal signed area can therefore have visibly different post-event amplitudes at one sensor if their durations differ. A short force pulse can consequently calibrate a low-frequency mode while underexciting a faster one in the same structure.
Derive an energy-consistent time update for a force record
A measured force history may be irregular enough that a closed-form convolution is inconvenient. The constant-average-acceleration Newmark update advances a linear oscillator one time step at a time. Let \(x_n,v_n,a_n\) be displacement, velocity and acceleration at \(t_n\). Approximate the acceleration over the step through its endpoint average in the velocity update, and use the corresponding trapezoidal velocity update for displacement. With step \(h\) the relations are
Enforce the actual equation \(ma_{n+1}+cv_{n+1}+kx_{n+1}=F_{n+1}\) at the new time. Gathering unknown acceleration terms gives effective mass \(m+ch/2+kh^2/4\). The right side is \(F_{n+1}-c(v_n+ha_n/2)-k(x_n+hv_n+h^2a_n/4)\). Solve that scalar equation and back-substitute into both kinematic updates. For several coupled linear coordinates the same derivation gives a linear system with an effective matrix.
For undamped unforced systems, multiply the average endpoint equilibrium by \(x_{n+1}-x_n=h(v_{n+1}+v_n)/2\). Differences of squares show that the discrete change in kinetic energy plus potential energy vanishes exactly. This property detects sign or unit errors in an implementation. It does not guarantee accurate phase at a coarse time step.
Check one step and distinguish stability from temporal resolution
Take \(m=2\,\mathrm{kg}\), \(c=0\), \(k=200\,\mathrm{N/m}\). Begin from \(x_0=0.010\,\mathrm m,\ v_0=0\) and release without applied force. Initial acceleration is
With \(h=0.10\,\mathrm s\), effective mass is
Its right side is \(-200[0.010+0.10^2(-1)/4]=-1.50\,\mathrm N\), giving \(a_1=-0.600\,\mathrm{m/s^2}\). The updates give
The initial energy is
after one step it is
The exact displacement at 0.10 s is nevertheless \(0.010\cos(1)=0.00540\,\mathrm m\). The numerical oscillator advances through angle \(2\arctan(\omega_nh/2)=0.9273\) rad per step instead of 1.00 rad. Over many cycles this small period error accumulates. Halving the step is a direct temporal convergence test. For a measured force pulse, a second check is that its sampled impulse and timing converge as well; an accurate oscillator update cannot recover a force feature missed by the acquisition system.
It is possible to predict the amount of step refinement needed for a phase-sensitive comparison. For small \(z=\omega_n h/2\), expand \(2\arctan z=2z-2z^3/3+\cdots\). Dividing the numerical angular advance by the true advance gives \(1-(\omega_n h)^2/12+\cdots\). The leading relative frequency error therefore falls by a factor of four when the step is halved. A one-percent target suggests \(\omega_nh\lesssim\sqrt{0.12}=0.346\) for this single undamped mode. At 10 rad/s that means roughly 0.035 s or less, before checking the sampling of the force itself. This criterion addresses the fundamental frequency, not the fastest contributing mode in a multi-degree model. If a high-frequency mode contributes significantly at the measurement station, use its frequency to assess temporal phase resolution or test convergence of the complete measured signal directly.
Once these conditions are met, comparing the computed displacement and velocity at the end of loading also tests the predicted initial condition for the subsequent free ring-down.