From first principles
Calculate the extension recorded by an angled strain gauge
A bonded straight gauge records fractional change of length along its own axis. Let adjacent material points be separated by \(d\mathbf x=\mathbf n\,ds\), where \(\mathbf n=(\cos\theta,\sin\theta)\) is a unit direction. For a smooth small displacement field \(\mathbf u\), their relative displacement is approximately \((\nabla\mathbf u)d\mathbf x\). To first order only the projection along the original separation changes its length:
The antisymmetric part represents infinitesimal rotation and has zero quadratic form. Writing engineering shear as \(\gamma_{xy}=2\epsilon_{xy}\) yields the observation equation
Three independently oriented grids provide three scalar observations of a uniform in-plane strain tensor. For directions \(0,45,90\) degrees, their combination \(2\epsilon_{45}-\epsilon_0-\epsilon_{90}\) recovers engineering shear. Converting this strain to stress additionally requires elastic properties and a local plane-stress or plane-strain model.
Derivation and applications
Remove transverse gauge sensitivity before reconstructing strain
A resistance grid responds primarily to extension along its long axis. Its transverse sensitivity may still matter when a small shear strain is inferred from differences of readings. Model a gauge at angle \(\theta\) as reporting \(g_\theta=\epsilon_\theta+\xi\epsilon_{\theta+90^\circ}\) after longitudinal calibration, with known dimensionless transverse response \(\xi\). Assume uniform infinitesimal in-plane strain over a rectangular \(0^\circ,45^\circ,90^\circ\) rosette, identical temperature compensation and the same \(\xi\) for each grid. Readings and strains below are dimensionless.
At the two axial gauges the transverse direction of one is the longitudinal direction of the other. Sum and subtract their equations to separate mean extension from normal-strain difference:
At \(45^\circ\) and \(135^\circ\), small-strain transformation gives normal strain \((\epsilon_x+\epsilon_y)/2\pm\gamma_{xy}/2\), where \(\gamma_{xy}\) is engineering shear strain. Inserting both projections into the calibrated reading gives
Remove the trace using the first equation and recover the corrected shear and principal strains:
If \(\xi=0\) this reduces to the ideal rosette. As \(\xi\) approaches unity all readings respond to the trace and directional information becomes poorly conditioned. A common temperature offset cancels from this shear combination but changes the inferred mean strain if no thermal correction is made.
Worked example
Recover a strain tensor from raw readings
For \(\xi=0.0200\) suppose \((g_0,g_{45},g_{90})=(298,200,-94)\) microstrain. The true strain sum is \(204/1.02=200\) microstrain, while its difference is \(392/0.98=400\) microstrain. Thus \(\epsilon_x=300\) and \(\epsilon_y=-100\) microstrain. The corrected engineering shear is \((400-298+94)/0.98=200\) microstrain. The principal values are \(100\pm223.6\), or \(323.6\) and \(-123.6\) microstrain.
Change the inputs and inspect this calculation below
Second application
Determine which calibration error matters for a pure shear test
Apply a reference pure engineering shear of \(500\) microstrain in the same axes. The corrected model predicts \(g_0=g_{90}=0\) and \(g_{45}=(1-0.0200)(500)/2=245\) microstrain. The ideal-gauge inversion would report \(490\) microstrain, low by \(2.0\%\). A uniform offset of \(12\) microstrain on every channel leaves this shear unchanged, separating the transverse response from the common offset in a calibration test.
Interactive calculation · Change the inputs of this example
Use the adjustable quantities to test the two worked calculations above. The plot recomputes this derivation’s balance or constitutive relation; its numerical readout reports the quantities needed for the forward calculation and the inverse or design question. Keep the fixed assumptions stated in the readout when comparing with the example values.
What a bonded gauge actually measures
A resistance gauge aligned with a line on a free surface records extension along that line. A single gauge cannot distinguish uniaxial tension from combined stretching and shear arranged to give the same directional extension. Bond three gauges at different angles near enough together that the local strain is approximately uniform. A rectangular rosette uses directions of zero, 45 and 90 degrees, all referred to the same positive surface axis.
Under infinitesimal deformation, a unit direction vector \(n=(\cos\theta,\sin\theta)\) experiences normal strain \(n^T\boldsymbol{\varepsilon}n\). Engineering shear strain \(\gamma_{xy}\) is twice the off-diagonal strain tensor component. Expanding the directional expression yields
The zero and 90° readings give \(\varepsilon_x,\varepsilon_y\) directly. The middle reading gives
A gauge at minus 45° measures the opposite shear contribution. A sketch of the physical gauge labels avoids reversing the inferred shear sign during data reduction.
Introduce the local stress assumption
At an unloaded outer surface the normal and shear tractions on that surface vanish. With \(z\) normal to it, this gives local plane stress. For isotropic linear elasticity and mechanical strains obtained after temperature correction, invert the plane-stress compliance equations and use the shear modulus for the remaining component.
A strain rosette measures only the in-plane quantities. A nonzero through-thickness strain is consistent with plane stress because the in-plane stresses cause Poisson contraction. Beneath a contact patch the local traction condition changes, so the same stress recovery would need additional information.
Interpret the readings on a plate
Suppose a steel surface gives \(400,\ 250,\ -100\) microstrain at zero, 45 and 90 degrees. The recovered shear strain is \(500-400+100=200\) microstrain. With \(E=210\,\mathrm{GPa}\) and \(\nu=0.30\), the stresses are \(85.38,\ 4.62,\ 16.15\,\mathrm{MPa}\) for \(x,y,xy\), respectively. The shear is positive under the stated gauge orientation. Converting microstrain to \(10^{-6}\) before multiplying by MPa is essential.
The principal stresses are the eigenvalues of this symmetric matrix. Its mean normal stress is 45.0 MPa, and its Mohr-circle radius is
Thus the two in-plane principal stresses are approximately 88.5 and 1.5 MPa. The major direction is \(\tfrac12\operatorname{atan2}(2\tau,\sigma_x-\sigma_y)=10.9^\circ\) from the zero gauge. A strain reading of −100 microstrain along \(y\) therefore does not imply compressive normal stress along that axis: Poisson contraction from the dominant \(x\) load accounts for much of that reading.
Resolve a uniform thermal signal
Uniform heating of an unconstrained isotropic plate adds the same free thermal strain \(\alpha\Delta T\) to each gauge reading, after allowing for the gauge instrumentation itself. It cancels from the inferred engineering shear because \(2-1-1=0\), but it persists in both recovered normal components. For a 20 K temperature rise and linear expansion \(12\times10^{-6}\,\mathrm{K^{-1}}\), subtract 240 microstrain from each reading before applying the mechanical plane-stress relation.
Reconstruct a surface strain from a delta rosette
The zero, 45 and 90 degree rosette is convenient but not the only useful placement. Introduce the strain-circle coordinates \(m=(\varepsilon_x+\varepsilon_y)/2,\ d=(\varepsilon_x-\varepsilon_y)/2,\ g=\gamma_{xy}/2\). Then each directional reading is \(e_\theta=m+d\cos 2\theta+g\sin2\theta\). Every installed gauge supplies one linear equation in these three unknowns. Gauge directions that are nearly parallel give nearly dependent equations, so a small error in an individual reading can then cause a large error in a recovered component.
For a delta rosette take directions \(0,60,120^\circ\). The doubled angles are equally spaced round the strain circle, so their cosine and sine values each sum to zero. Adding all three readings gives
The first reading then gives
subtracting the last two cancels both \(m\) and their identical cosine terms and gives
The in-plane principal strains and their physical orientation follow without a material assumption:
The half-angle is necessary because a straight gauge has the same reading after a physical rotation of 180°. For an isotropic elastic solid the principal stress directions coincide with these strain directions. Orthotropic laminates can give stress and strain axes that differ, so converting a strain circle into stresses would require the material compliance in the specimen’s axes.
OneSimulation · How does a small gauge error become a large transverse strain?
A bonded gauge observes the normal strain along its axis. Reconstruct the two normal components and the engineering shear from three readings. Give only the middle reading a positive bias of 5 µε. The factor multiplying the shear in the observation matrix follows from rotating a symmetric tensor with \(\epsilon_{xy}=\gamma_{xy}/2\).
OneSimulation solves the same three-unknown system for two different layouts. At 0°, 45° and 90°, the last gauge directly measures transverse strain. At 0°, 10° and 20°, all gauges see mostly the longitudinal direction. The reconstructed transverse strain now misses by −155.8 µε. Fitting three readings exactly supplies no independent check on accuracy.
"""Compare strain-rosette geometries with the same middle-gauge error."""
import matplotlib.pyplot as plt
import numpy as np
from onesim.numerics.linear.matrices.dense_linear_algebra import solve_dense
true_strain = np.array([100., -60., 80.]) # ex, ey, engineering shear in µε
bias = 5.0 # µε added to the middle gauge
rotation = np.arange(0, 181)
def gauge_rows(degrees):
angle = np.deg2rad(degrees)
c, s = np.cos(angle), np.sin(angle)
return np.column_stack((c**2, s**2, c*s))
fig, ax = plt.subplots(figsize=(7, 4), constrained_layout=True)
for spacing, colour in [(45, "#19596a"), (10, "#a5442e")]:
layout = gauge_rows([0, spacing, 2*spacing])
readings = layout @ true_strain
assert np.allclose(solve_dense(layout, readings), true_strain)
readings[1] += bias
inferred = solve_dense(layout, readings)
error = gauge_rows(rotation) @ (inferred - true_strain)
ax.plot(rotation, error, color=colour, label=f"Gauge spacing {spacing}°")
print(f"{spacing}°: error at 90° = {error[90]:.2f} µε")
ax.axhline(0, color="0.5", linewidth=0.7)
ax.set(xlabel="Direction of predicted normal strain (degrees)",
ylabel="Prediction error (µε)", xlim=(0, 180))
ax.legend()
fig.savefig("engineering-mechanics.png", dpi=170)

Vary the parameters of this exact example in the chapter’s interactive calculation.
Check an installed rosette using an independent gauge
On a loaded aluminium plate a delta rosette reads \(e_0=350,\ e_{60}=200,\ e_{120}=-100\) microstrain. The mean is 150 microstrain; \(d=200\) and \(g=300/\sqrt3=173.2\) microstrain. Thus \(\varepsilon_x=350,\varepsilon_y=-50,\gamma_{xy}=346.4\) microstrain. The strain-circle radius is \(\sqrt{200^2+173.2^2}=264.6\) microstrain. Principal strains are 414.6 and −114.6 microstrain, with largest extension along \(\theta_1=20.45^\circ\) from the zero gauge.
Before converting these figures to stress, predict an independent reading at 90°. The directional equation gives \(m-d=-50\) microstrain, which can be checked with a fourth gauge. If it instead reads +50 microstrain, possible explanations include angular mislabelling, an adhesive defect or a spatial strain gradient across the footprint. In fact the maximum local slope of the directional reading with respect to angle is \(2\sqrt{d^2+g^2}\) per radian. A two-degree placement error can therefore contribute at most about \(529(2\pi/180)=18.5\) microstrain for this field to first order. An observed 100 microstrain discrepancy would be too large to explain by that tolerance alone. This cross-check assesses the measurement geometry before uncertainty in elastic moduli enters the interpretation.
Close to an equibiaxial strain state both \(d\) and \(g\) are small, so angle estimates from \(\operatorname{atan2}(g,d)\) can jump substantially between repeated readings. That sign of numerical sensitivity has a physical interpretation: when the strain circle collapses, every direction is principal. The nearly equal principal strain values may still be well determined even though a reported principal orientation is almost arbitrary. Quoting the circle radius together with the angle gives a reader enough information to decide whether the orientation is useful.
Interactive calculation · Change the inputs of this example