Fundamentals / Mechanical engineering / Control engineering

Uncertainty envelopes and robust stability

Turn a bounded discrepancy between plant and model into a frequency-by-frequency test of the feedback design.

From first principles

Derive a feedback bound from a fractional plant error

A frequency-dependent model error matters through the feedback path in which it enters. Suppose an actual plant can be represented as \(P=P_0(1+W\Delta)\), with nominal plant \(P_0\), a known stable weight \(W\) and stable uncertainty satisfying \(|\Delta(i\omega)|\leq1\). Use a fixed controller \(C\) and assume the nominal interconnection is internally stable. Define \(L_0=CP_0\) and expand the perturbed characteristic factor.

\[1+CP=1+L_0+L_0W\Delta=(1+L_0)(1+T_0 W\Delta),\]
\[T_0=\frac{L_0}{1+L_0}.\]

The second factor describes how the unknown part feeds back around the nominal closed loop. If the magnitude of its variable term stays strictly below one at every frequency, it cannot reach the critical value \(-1\). The small-gain condition for stable interconnected factors is

\[\sup_\omega |T_0(i\omega)W(i\omega)|<1 .\]

This gives a sufficient certificate for every uncertainty in the specified class. The bound permits less modelling error where the complementary sensitivity is large. A failed inequality identifies a missing certificate; determining actual instability requires the particular plant error or a tighter description of it.

Background · Sensitivity
\[S(s)=1/[1+L(s)]\]

For a scalar unity negative-feedback loop this gives one closed-loop transfer. The point where a disturbance enters determines which transfer the observer measures.

Derivation and applications

Represent a transport-delay error as multiplicative uncertainty

A frequency sweep of a conveyor or thermal transport path may fit the gain well while leaving an uncertain delay. Suppose the actual stable plant is \(P(s)=P_0(s)e^{-s\Delta t}\), with a nominal model containing the accurately known part of the delay. Let the extra delay lie between zero and \(d\). At sinusoidal frequency \(\omega\), define the fractional model error as \(E=P/P_0-1\). Factoring the difference of the two unit phasors gives

\[E(i\omega)=e^{-i\omega\Delta t}-1=-2i\,e^{-i\omega\Delta t/2}\sin(\omega\Delta t/2).\]

This is a chord on the unit circle. Its magnitude grows with delay until the phasors point in opposite directions. Maximising over the stated delay interval therefore gives a monotone envelope which stays at two after the interval first contains a half-cycle delay.

\[W_d(\omega)=\max_{0\leq\Delta t\leq d}|E|=\begin{cases}2\sin(\omega d/2),&\omega d\leq\pi,\\2,&\omega d\geq\pi.\end{cases}\]

For nominal loop \(L_0=C P_0\) the perturbation multiplies the complementary sensitivity \(T_0=L_0/(1+L_0)\) in the characteristic equation. If the nominal closed loop is internally stable and the bounded error is stable, keeping the product below unity at all frequencies gives a sufficient robust-stability test.

\[1+CP=(1+L_0)(1+T_0E),\qquad |T_0(i\omega)|W_d(\omega)<1 .\]

At low frequencies the envelope approaches \(\omega d\). This dependence on frequency explains how an almost exact steady gain can coexist with a substantial feedback discrepancy near crossover.

Worked example

Audit a transport path at one frequency

A thermal experiment bounds extra delay by 20.0 ms. At \(\omega=30.0\) rad/s the worst relative error is \(2\sin(0.300)=0.591\). If \(|T_0|=1.40\), the pointwise product is 0.827, within the bound at that frequency. Repeating at every relevant frequency is necessary for the full small-gain conclusion; this single value establishes only the local allowance.

Change the inputs and inspect this calculation below

Second application

Derive a timing requirement from a measured peak

At 40.0 rad/s another loop has \(|T_0|=2.00\). The allowable envelope must be below 0.500. On the rising branch the maximum extra delay is therefore

\[d<2\arcsin(0.250)/40.0=12.6\,\mathrm{ms}.\]

A measured 15.0 ms spread would give \(4\sin(0.300)=1.18\) for the product, so this sufficient certificate would no longer settle stability there.

Interactive calculation · Change the inputs of this example

Use the adjustable quantities to test the two worked calculations above. The plot recomputes this derivation’s balance or constitutive relation; its numerical readout reports the quantities needed for the forward calculation and the inverse or design question. Keep the fixed assumptions stated in the readout when comparing with the example values.

What do several plant tests tell us?

The gain of a drive changes as it warms up, and a flexible mounting introduces poorly measured phase lag at high frequency. Let \(P_0\) be a nominal model. One useful description is multiplicative uncertainty, \(P=P_0(1+W\Delta)\), with stable dimensionless \(\Delta\) of gain at most one and a specified frequency weight \(W\). The magnitude of \(W\) bounds relative error. Estimate it from \(|P/P_0-1|\) across an ensemble of measurements, retaining phase in the complex ratio. A 20% amplitude difference and a 20° phase difference generally produce a larger relative error than either alone.

Where \(P_0\) is close to zero this relative description can be poorly conditioned. An additive uncertainty \(P=P_0+W_a\Delta\) can describe an absolute error floor there. A bound fitted only at sampled frequencies requires a reason to hold between samples, especially near flexible resonances. A robustness calculation is conditional on this modelling work.

Factor the perturbed characteristic equation

For the nominal controller \(C\), set \(L_0=P_0C\) and \(T_0=L_0/(1+L_0)\). Under multiplicative perturbation,

\[1+PC=(1+L_0)(1+W T_0\Delta).\]

Assume internal stability of the nominal interconnection and stable, proper uncertainty factors with no hidden unstable cancellation. If \(\sup_\omega|W(i\omega)T_0(i\omega)|<1\), the perturbation loop has gain less than one and cannot destabilise the feedback. One way to see the mechanism is the convergent inverse series \(1-G+G^2-\cdots\) for \(G=WT_0\Delta\) in the stable-system norm. The pointwise bound protects against all allowed dynamic phase choices. Failure of a sufficient test alone does not prove the particular measured plant unstable.

Work a frequency-domain budget

At one frequency a nominal loop has \(L_0=-0.8+0.4i\). Then \(|1+L_0|=\sqrt{0.2}\), \(|L_0|=\sqrt{0.8}\), and \(|T_0|=2\). Relative uncertainty below 50% at that frequency keeps \(|W T_0|<1\) there. A measured 60% bound crosses this threshold. Geometrically the perturbed loop samples a disk centred at \(L_0\) of radius \(|L_0 W|\). At 50% its rim touches \(-1\). Other frequencies still require examination, and a physically narrower family such as a single real gain may occupy far less than the full disk.

Add a performance requirement

A stable loop can still amplify an output disturbance unacceptably. For the uncertain plant the sensitivity is \(S=S_0/(1+WT_0\Delta)\). The triangle inequality gives \(|S|\le |S_0|/(1-|WT_0|)\) where the denominator is positive. If \(|S_0|=0.10\) and \(|WT_0|\le0.25\), disturbances can be amplified by at most 0.133 in this bound. Very near the robustness limit that bound becomes large. Shaping the nominal loop for a small uncertainty product near troublesome resonances can therefore protect both stability and useful performance. Record the sensor configuration, loading and frequency band over which the underlying plant measurements were made.

Distinguish absolute from relative uncertainty

Several tested plants may differ by an approximately fixed absolute transfer at high frequency although their nominal output gain is nearly zero there. Dividing each difference by a near-zero nominal transfer gives an enormous relative error and may make a multiplicative envelope awkward. An additive description writes \(P_a=P_0+W_a\Delta\), where \(|\Delta(i\omega)|\le1\), the stable filter \(W_a\) has the same units as the plant and its magnitude bounds absolute discrepancies. The controller \(C\) and nominal plant first form an internally stable feedback system. Assume the uncertainty interconnection is well posed and the normalised uncertainty is stable.

Factor the uncertain return difference using the nominal sensitivity \(S_0=1/(1+C P_0)\):

\[1+CP_a=(1+CP_0)[1+W_a C S_0\Delta].\]

For unstructured complex uncertainty the small-gain bound \(\|W_a C S_0\|_\infty<1\) is sufficient for robust stability. The relevant nominal transfer is from measurement error to control effort, \(CS_0\), rather than complementary sensitivity alone. At high frequency \(S_0\) often approaches one, so a derivative action that increases high-frequency controller gain can stress an additive uncertainty bound even where nominal loop gain has already fallen.

The inequality uses the worst permitted complex phase at each frequency. A point violating the envelope test indicates loss of this guarantee. It does not by itself establish that a particular measured plant is unstable. Conversely a few passing frequency samples do not certify the continuous-frequency supremum.

Budget uncertainty for a lightly coupled actuator resonance

Suppose a calibration expresses position in millimetres and actuator input in volts. At 40 rad/s the nominal gain is only \(0.020\,\mathrm{mm/V}\), while an unmodelled flexible path can add up to \(0.030\,\mathrm{mm/V}\) in any phase. A measured nominal loop has \(|CS_0|=18\,\mathrm{V/mm}\) there, giving an uncertainty product \(0.030(18)=0.54\). The corresponding allowable absolute uncertainty before the unit threshold is

\[1/18=0.0556\,\mathrm{mm/V}.\]

Stating only the 150% relative plant discrepancy would conceal the controller-dependent margin at that frequency.

At 70 rad/s suppose the absolute uncertainty bound increases to \(0.045\,\mathrm{mm/V}\) and \(|CS_0|=25\,\mathrm{V/mm}\). Their product is 1.125. To reserve a factor of 1.25 on the uncertainty envelope, impose a target product of at most 0.80. Then \(|CS_0|\) must be at most \(0.80/0.045=17.8\,\mathrm{V/mm}\) at that frequency. A revised compensator with measured \(|CS_0|=16\) gives 0.72 at the suspect point. Check the complete response around any new filter resonance and recompute nominal tracking. Reducing this single frequency peak cannot establish whether the remainder of the frequency band also satisfies the reserve.

Suppose the absolute uncertainty envelope comes from three nominally identical machines. At each frequency calculate the complex difference of each measured response from the nominal complex response before taking magnitudes. At 70 rad/s, two transfer measurements of equal magnitude but opposite phase can differ by twice that magnitude. Subtracting magnitudes alone would assign zero discrepancy. Also retain independent test uncertainty such as force calibration and motion-sensor noise, which may be especially important where nominal motion is small. The largest observed discrepancy only covers those three machines and operating conditions. A justified production bound requires considering the frequency regions between measurement points and whether later mounting or payload changes can introduce another flexible path.

Test a frequency-dependent uncertainty budget

Use the same nominal loop and model multiplicative uncertainty by the weight \(W(s)=(0.1+a s)/(1+s)\) times a stable unit-gain perturbation. Inspect the product \(|WT|\) rather than the two factors separately. A uniform bound below one supplies a sufficient robust-stability test.

Test a frequency-dependent uncertainty budget. Horizontal axis: Angular frequency (rad/s). Vertical axis: Uncertainty-weighted loop magnitude. Data follow the figure.
The largest products occur near the nominal resonance, not at the largest plotted frequency where |T| is already small. A curve crossing unity means this envelope test no longer certifies the whole allowed family; a particular tested plant may still be stable.
Read values from the plot
Uncertainty-weighted loop magnitude at selected values of Angular frequency (rad/s).
Angular frequency (rad/s)High-frequency relative error 0.4High-frequency relative error 0.8High-frequency relative error 1.2Small-gain threshold
0.030.100690.102810.106261
0.175330.121120.170820.2311
1.02470.377430.738781.10371
5.98870.0487170.0973710.146041
350.00130940.00261870.0039281

Download all 301 plotted samples (CSV)

Interactive calculation · change the inputs of this example

Increase the high-frequency uncertainty budget and locate the maximum weighted response over the plotted band.

The curves below are recalculated from this section’s equations in your browser. The fixed reference plot above remains available for comparison.

Study the full derivation

Sensitivity, bandwidth and the integral price of disturbance rejection · System dynamics, feedback and estimation

A regulator attenuates a slowly varying output load yet amplifies another disturbance at a higher frequency. Separate the paths by which reference, measurement noise and physical disturbance reach the recorded variable, then derive an integral identity that explains why a stable loop can redistribute sensitivity across frequency.