Application Library / Chemistry

Equivalent-circuit battery identification

Series resistance and RC branch of a lithium-ion equivalent-circuit model identified from the terminal voltage of a pulse test.

To reproduce the case, put its notebook and accompanying inputs in the same folder. Use the Python environment set up in the installation tutorial. Start with the original parameters and compare the result with the check reported below.

Least-squares fitCircuit solverSynthetic data

Run this example yourself. The OneSimulation Runtime brings the full Python library and an MCP server for Codex and Claude Code. It starts with a seven-day trial, then from €19 per month before any applicable tax.

Start the 7-day trial Compare the plans

Equivalent-circuit battery identification
Equivalent-circuit battery identification. Run the notebook to produce its own figures.

What it computes

OneSimulation solves the equivalent circuit (open-circuit voltage source, R0, R1 || C1, current load) with its circuit solver inside a SimulationStudyService, whose Levenberg-Marquardt least-squares fit adjusts R0, R1 and tau1 to the voltage and returns their covariance; every residual evaluation is a real circuit run. The data are synthetic: 1 mV noise.

What it checks

From a start at twice R0, 0.4 R1 and 2.7 tau1, 28 circuit runs recover R0 = 15.015 +/- 0.032 mOhm, R1 = 9.966 +/- 0.036 mOhm and tau1 = 30.18 +/- 0.24 s (true 15, 10, 30), all within one standard error; residuals 1.04 mV rms.

The notebook

The complete notebook, cell by cell. Run it to produce the figures and the comparison printout.

Equivalent-circuit models describe a battery cell without any knowledge of its internal chemistry: a voltage source for the open-circuit voltage \(U_\mathrm{OCV}(s)\) as a function of the state of charge \(s\), a series resistance \(R_0\) for the instantaneous (ohmic) response, and resistor-capacitor branches for the slower polarisation. With one branch,

\[U=U_\mathrm{OCV}(s)-R_0\,I-u_1,\qquad \frac{du_1}{dt}=\frac{I}{C_1}-\frac{u_1}{R_1C_1},\qquad \frac{ds}{dt}=-\frac{I}{Q},\]

with the current \(I\) positive on discharge, the capacity \(Q\) and the relaxation time \(\tau_1=R_1C_1\). A pulse test (current pulses with rests in between) separates the parameters: the voltage jumps at the pulse edges give \(R_0\), the slow relaxation after them \(R_1\) and \(\tau_1\).

OneSimulation solves the circuit (voltage source, \(R_0\), the \(R_1C_1\) branch, current load) with its circuit solver. The SimulationStudyService turns it into a least-squares problem: fit runs the circuit for trial values of \((R_0,R_1,\tau_1)\), forms the voltage residuals divided by the noise level and minimises their sum of squares with the Levenberg-Marquardt method. It returns the estimates with their linearised covariance in physical units.

Reference. G. L. Plett, Battery Management Systems, Vol. I: Battery Modeling, Artech House 2015, ch. 2; the pulse test follows the hybrid pulse power characterisation idea of the FreedomCAR Battery Test Manual (INL 2003). The data are synthetic: generated by the same circuit from the "true" values \(R_0=15\) mΩ, \(R_1=10\) mΩ, \(\tau_1=30\) s with normally distributed noise of 1 mV. A correct identification recovers these values within the uncertainty the noise allows and leaves residuals of the size of the noise.

import numpy as np
from onesim.physics.systems import (
    Circuit,
    CircuitCapacitor,
    CircuitCurrentSource,
    CircuitResistor,
    CircuitVoltageSource,
)
from onesim.simulation.studies import SimulationStudyService, StudyParameter
from onesim.visualization import plots, theme

theme.set()

Cell and pulse test

A 3 Ah cell, starting at 80 % state of charge. The test applies a 10 s discharge pulse at 2C (6 A), 40 s rest, a 10 s charge pulse at 1.5C, 40 s rest, then the same at a lower state of charge after a 300 s discharge at 1C; the voltage is sampled every second. The open-circuit voltage curve is taken as known (measured beforehand).

capacity, start, noise = 3.0 * 3600.0, 0.80, 1e-3
open_circuit = lambda s: 3.45 + 0.55 * s + 0.08 * np.log(s / (1.0 - s)) / 4.0
steps = np.array(
    [
        (0, 6.0),
        (10, 0.0),
        (50, -4.5),
        (60, 0.0),
        (100, 3.0),
        (400, 0.0),
        (500, 6.0),
        (510, 0.0),
        (550, -4.5),
        (560, 0.0),
    ]
)
load = lambda t: steps[np.searchsorted(steps[:, 0], t, side="right") - 1, 1]
times = np.arange(0.0, 661.0, 1.0)
state = start - np.r_[0.0, np.cumsum([load(t) for t in times[:-1]])] / capacity
print(
    f"state of charge from {state[0]:.3f} to {state[-1]:.3f}, open-circuit voltage from {open_circuit(state[0]):.4f} V to {open_circuit(state[-1]):.4f} V"
)

Circuit model

pulse_test(values) builds the circuit for one parameter set; the voltage source follows the open-circuit voltage along the coulomb-counted state of charge.

pulse_test = lambda values: Circuit(
    components=(
        CircuitVoltageSource(
            name="ocv",
            positive="p",
            negative="0",
            voltage=lambda t: open_circuit(np.interp(t, times, state)),
        ),
        CircuitResistor(
            name="r0", positive="p", negative="a", resistance=1e-3 * values["r0"]
        ),
        CircuitResistor(
            name="r1", positive="a", negative="t", resistance=1e-3 * values["r1"]
        ),
        CircuitCapacitor(
            name="c1",
            positive="a",
            negative="t",
            capacitance=values["tau1"] / (1e-3 * values["r1"]),
            initial_voltage=0.0,
        ),
        CircuitCurrentSource(name="load", positive="t", negative="0", current=load),
    )
)
study = SimulationStudyService(
    (
        StudyParameter("r0", 1.0, 50.0),
        StudyParameter("r1", 1.0, 50.0),
        StudyParameter("tau1", 2.0, 200.0),
    ),
    pulse_test,
    lambda circuit: {f"u_{i}": u for i, u in enumerate(circuit.voltages["t"])},
    solve=lambda circuit: circuit.solve(times=times, max_step=0.25),
)

Synthetic measurements

The true circuit is run once and normally distributed noise of 1 mV is added (fixed seed).

true = {"r0": 15.0, "r1": 10.0, "tau1": 30.0}
rng = np.random.default_rng(2026)
clean = study.sweep(combinations=[true]).runs[0].measurements
data = np.array([clean[f"u_{i}"] for i in range(times.size)]) + rng.normal(
    0.0, noise, times.size
)

Identification

Bounds: resistances between 1 and 50 mΩ, relaxation time between 2 and 200 s. Levenberg-Marquardt starts at \(R_0=30\) mΩ, \(R_1=4\) mΩ, \(\tau_1=80\) s.

start_values = {"r0": 30.0, "r1": 4.0, "tau1": 80.0}
fit = study.fit(
    residuals=lambda m: np.array(
        [(m[f"u_{i}"] - data[i]) / noise for i in range(times.size)]
    ),
    start=start_values,
    method="levenberg_marquardt",
    maximum_runs=100,
)

Comparison with the true values

Standard errors from the linearised covariance, scaled with the residual variance.

print(
    f"{fit.run_count} circuit simulations (including the data run), converged: {fit.converged}, rank {fit.rank}, "
    f"χ² = {fit.residuals @ fit.residuals:.1f} for {fit.degrees_of_freedom} degrees of freedom"
)
print("parameter   estimate ± standard error    true    deviation")
for name, unit in (("r0", "mΩ"), ("r1", "mΩ"), ("tau1", "s")):
    print(
        f"{name:8s} {fit.parameters[name]:10.4f} ± {fit.standard_errors[name]:.4f} {unit:2s} {true[name]:8.2f}   "
        f"{(fit.parameters[name] - true[name]) / fit.standard_errors[name]:+6.2f} σ"
    )
correlation = fit.covariance / np.sqrt(
    np.outer(np.diag(fit.covariance), np.diag(fit.covariance))
)
print(
    f"correlations: R0-R1 {correlation[0, 1]:+.2f}, R0-τ1 {correlation[0, 2]:+.2f}, R1-τ1 {correlation[1, 2]:+.2f}; "
    f"rms voltage residual {1e3 * noise * np.sqrt(np.mean(fit.residuals ** 2)):.3f} mV (noise {1e3 * noise:.1f} mV)"
)

Figure

The measured and fitted terminal voltage with the current profile; a close-up of one pulse, where the instantaneous jump (\(R_0\)) and the relaxation (\(R_1\), \(\tau_1\)) separate; and the residuals (dotted: ± the noise level).

fitted, first = (
    np.array([run.measurements[f"u_{i}"] for i in range(times.size)])
    for run in study.sweep(combinations=[dict(fit.parameters), start_values]).runs
)
fig = plots.figure(1, 3, size=(17, 5))
plots.line(
    times / 60,
    {"fitted model": fitted},
    points={"pulse-test data": (times[::4] / 60, data[::4])},
    right={"current [A]": np.array([load(t) for t in times])},
    xlabel="time [min]",
    ylabel="terminal voltage [V]",
    right_label="current [A] (discharge > 0)",
    title="Pulse test",
    legend="lower left",
    ax=fig[0],
)
window = (times >= 490) & (times <= 600)
plots.line(
    times[window],
    {"fitted model": fitted[window]},
    points={"pulse-test data": (times[window], data[window])},
    reference={"start values": first[window]},
    xlabel="time [s]",
    ylabel="terminal voltage [V]",
    title="Second pulse pair, close-up",
    legend="lower right",
    ax=fig[1],
)
plots.line(
    points={"data - model": (times / 60, 1e3 * (data - fitted))},
    hlines=[1e3 * noise, -1e3 * noise],
    xlabel="time [min]",
    ylabel="voltage residual [mV]",
    title="Residuals",
    legend="upper right",
    ax=fig[2],
)
plots.show()

Going further

Add a second RC branch with a longer relaxation time and refit: with these data its parameters stay poorly determined, which the covariance shows at once. Make the resistances functions of the state of charge, or fit the open-circuit voltage curve as well from a slow (C/20) discharge. Real cycler data replace the synthetic data array directly.

Original OneSimulation Showcase entry