"""OneSimulation example: identifying an equivalent-circuit battery model from a pulse test.
Requires the installed, activated OneSimulation runtime.

A lithium-ion cell is described by an open-circuit voltage source, a series resistance
and one resistor-capacitor branch. The three circuit parameters are estimated from the
terminal voltage of a pulse test by a Levenberg-Marquardt least-squares fit that runs the
circuit simulation at every trial point. The test data are synthetic, generated from known
parameters with voltage noise, so the recovered values can be checked.
"""

# # Identifying an equivalent-circuit battery model from a pulse test
#
# Equivalent-circuit models describe a battery cell without any knowledge of its
# internal chemistry: a voltage source for the open-circuit voltage $U_\mathrm{OCV}(s)$
# as a function of the state of charge $s$, a series resistance $R_0$ for the
# instantaneous (ohmic) response, and resistor-capacitor branches for the slower
# polarisation. With one branch,
#
# $$U=U_\mathrm{OCV}(s)-R_0\,I-u_1,\qquad
#   \frac{du_1}{dt}=\frac{I}{C_1}-\frac{u_1}{R_1C_1},\qquad
#   \frac{ds}{dt}=-\frac{I}{Q},$$
#
# with the current $I$ positive on discharge, the capacity $Q$ and the relaxation time
# $\tau_1=R_1C_1$. A pulse test (current pulses with rests in between) separates the
# parameters: the voltage jumps at the pulse edges give $R_0$, the slow relaxation after
# them $R_1$ and $\tau_1$.
#
# OneSimulation solves the circuit (voltage source, $R_0$, the $R_1C_1$ branch, current
# load) with its circuit solver. The `SimulationStudyService` turns it into a least-squares
# problem: `fit` runs the circuit for trial values of $(R_0,R_1,\tau_1)$, forms the voltage
# residuals divided by the noise level and minimises their sum of squares with the
# Levenberg-Marquardt method. It returns the estimates with their linearised covariance in
# physical units.
#
# **Reference.** G. L. Plett, *Battery Management Systems, Vol. I: Battery Modeling*,
# Artech House 2015, ch. 2; the pulse test follows the hybrid pulse power
# characterisation idea of the *FreedomCAR Battery Test Manual* (INL 2003). The data are
# synthetic: generated by the same circuit from the "true" values $R_0=15$ mΩ,
# $R_1=10$ mΩ, $\tau_1=30$ s with normally distributed noise of 1 mV. A correct
# identification recovers these values within the uncertainty the noise allows and
# leaves residuals of the size of the noise.

import numpy as np
from onesim.physics.systems import (
    Circuit,
    CircuitCapacitor,
    CircuitCurrentSource,
    CircuitResistor,
    CircuitVoltageSource,
)
from onesim.simulation.studies import SimulationStudyService, StudyParameter
from onesim.visualization import plots, theme

theme.set()


# ## Cell and pulse test
#
# A 3 Ah cell, starting at 80 % state of charge. The test applies a 10 s discharge pulse
# at 2C (6 A), 40 s rest, a 10 s charge pulse at 1.5C, 40 s rest, then the same at a
# lower state of charge after a 300 s discharge at 1C; the voltage is sampled every
# second. The open-circuit voltage curve is taken as known (measured beforehand).

capacity, start, noise = 3.0 * 3600.0, 0.80, 1e-3
open_circuit = lambda s: 3.45 + 0.55 * s + 0.08 * np.log(s / (1.0 - s)) / 4.0
steps = np.array(
    [
        (0, 6.0),
        (10, 0.0),
        (50, -4.5),
        (60, 0.0),
        (100, 3.0),
        (400, 0.0),
        (500, 6.0),
        (510, 0.0),
        (550, -4.5),
        (560, 0.0),
    ]
)
load = lambda t: steps[np.searchsorted(steps[:, 0], t, side="right") - 1, 1]
times = np.arange(0.0, 661.0, 1.0)
state = start - np.r_[0.0, np.cumsum([load(t) for t in times[:-1]])] / capacity
print(
    f"state of charge from {state[0]:.3f} to {state[-1]:.3f}, open-circuit voltage from {open_circuit(state[0]):.4f} V to {open_circuit(state[-1]):.4f} V"
)

# ## Circuit model
#
# `pulse_test(values)` builds the circuit for one parameter set; the voltage source
# follows the open-circuit voltage along the coulomb-counted state of charge.

pulse_test = lambda values: Circuit(
    components=(
        CircuitVoltageSource(
            name="ocv",
            positive="p",
            negative="0",
            voltage=lambda t: open_circuit(np.interp(t, times, state)),
        ),
        CircuitResistor(
            name="r0", positive="p", negative="a", resistance=1e-3 * values["r0"]
        ),
        CircuitResistor(
            name="r1", positive="a", negative="t", resistance=1e-3 * values["r1"]
        ),
        CircuitCapacitor(
            name="c1",
            positive="a",
            negative="t",
            capacitance=values["tau1"] / (1e-3 * values["r1"]),
            initial_voltage=0.0,
        ),
        CircuitCurrentSource(name="load", positive="t", negative="0", current=load),
    )
)
study = SimulationStudyService(
    (
        StudyParameter("r0", 1.0, 50.0),
        StudyParameter("r1", 1.0, 50.0),
        StudyParameter("tau1", 2.0, 200.0),
    ),
    pulse_test,
    lambda circuit: {f"u_{i}": u for i, u in enumerate(circuit.voltages["t"])},
    solve=lambda circuit: circuit.solve(times=times, max_step=0.25),
)

# ## Synthetic measurements
#
# The true circuit is run once and normally distributed noise of 1 mV is added (fixed seed).

true = {"r0": 15.0, "r1": 10.0, "tau1": 30.0}
rng = np.random.default_rng(2026)
clean = study.sweep(combinations=[true]).runs[0].measurements
data = np.array([clean[f"u_{i}"] for i in range(times.size)]) + rng.normal(
    0.0, noise, times.size
)

# ## Identification
#
# Bounds: resistances between 1 and 50 mΩ, relaxation time between 2 and 200 s.
# Levenberg-Marquardt starts at $R_0=30$ mΩ, $R_1=4$ mΩ, $\tau_1=80$ s.

start_values = {"r0": 30.0, "r1": 4.0, "tau1": 80.0}
fit = study.fit(
    residuals=lambda m: np.array(
        [(m[f"u_{i}"] - data[i]) / noise for i in range(times.size)]
    ),
    start=start_values,
    method="levenberg_marquardt",
    maximum_runs=100,
)

# ## Comparison with the true values
#
# Standard errors from the linearised covariance, scaled with the residual variance.

print(
    f"{fit.run_count} circuit simulations (including the data run), converged: {fit.converged}, rank {fit.rank}, "
    f"χ² = {fit.residuals @ fit.residuals:.1f} for {fit.degrees_of_freedom} degrees of freedom"
)
print("parameter   estimate ± standard error    true    deviation")
for name, unit in (("r0", "mΩ"), ("r1", "mΩ"), ("tau1", "s")):
    print(
        f"{name:8s} {fit.parameters[name]:10.4f} ± {fit.standard_errors[name]:.4f} {unit:2s} {true[name]:8.2f}   "
        f"{(fit.parameters[name] - true[name]) / fit.standard_errors[name]:+6.2f} σ"
    )
correlation = fit.covariance / np.sqrt(
    np.outer(np.diag(fit.covariance), np.diag(fit.covariance))
)
print(
    f"correlations: R0-R1 {correlation[0, 1]:+.2f}, R0-τ1 {correlation[0, 2]:+.2f}, R1-τ1 {correlation[1, 2]:+.2f}; "
    f"rms voltage residual {1e3 * noise * np.sqrt(np.mean(fit.residuals ** 2)):.3f} mV (noise {1e3 * noise:.1f} mV)"
)

# ## Figure
#
# The measured and fitted terminal voltage with the current profile; a close-up of one
# pulse, where the instantaneous jump ($R_0$) and the relaxation ($R_1$, $\tau_1$)
# separate; and the residuals (dotted: ± the noise level).

fitted, first = (
    np.array([run.measurements[f"u_{i}"] for i in range(times.size)])
    for run in study.sweep(combinations=[dict(fit.parameters), start_values]).runs
)
fig = plots.figure(1, 3, size=(17, 5))
plots.line(
    times / 60,
    {"fitted model": fitted},
    points={"pulse-test data": (times[::4] / 60, data[::4])},
    right={"current [A]": np.array([load(t) for t in times])},
    xlabel="time [min]",
    ylabel="terminal voltage [V]",
    right_label="current [A] (discharge > 0)",
    title="Pulse test",
    legend="lower left",
    ax=fig[0],
)
window = (times >= 490) & (times <= 600)
plots.line(
    times[window],
    {"fitted model": fitted[window]},
    points={"pulse-test data": (times[window], data[window])},
    reference={"start values": first[window]},
    xlabel="time [s]",
    ylabel="terminal voltage [V]",
    title="Second pulse pair, close-up",
    legend="lower right",
    ax=fig[1],
)
plots.line(
    points={"data - model": (times / 60, 1e3 * (data - fitted))},
    hlines=[1e3 * noise, -1e3 * noise],
    xlabel="time [min]",
    ylabel="voltage residual [mV]",
    title="Residuals",
    legend="upper right",
    ax=fig[2],
)
plots.show()

# ## Going further
#
# Add a second RC branch with a longer relaxation time and refit: with these data its
# parameters stay poorly determined, which the covariance shows at once. Make the
# resistances functions of the state of charge, or fit the open-circuit voltage curve as
# well from a slow (C/20) discharge. Real cycler data replace the synthetic `data`
# array directly.