Balance drift against diffusion
Measure \(z\) upwards from the bottom of a closed cell. A sphere of volume \(V\) displaces fluid of density \(\rho_f\). The downward gravitational force on the particle exceeds the upward buoyancy force by \(m_bg\), where \(m_b=V(\rho_p-\rho_f)\). Signed buoyant mass is what a concentration profile can reveal. Let \(\mu\) denote mobility, the ratio of speed to applied force. For dilute, independently moving particles at uniform temperature, the total vertical number flux is
At steady state the flux is constant, and impermeable cell ends set that constant to zero. The Einstein relation \(D=\mu k_BT\) eliminates the mobility. Integrating \(d\ln n/dz=-a\) with \(a=m_bg/(k_BT)\) gives
The signed slope changes sign for buoyant particles and vanishes at exact density matching. Viscosity affects the time to reach equilibrium.
Suppose the camera counts centres in equal-width horizontal slices of a column with uniform cross-section. A bin centred at \(z_i\) has expected count proportional to \(e^{-az_i} \int_{-h/2}^{h/2}e^{-au}du\). The integral is common to all bins, hence normalising the exponential values at their centres yields the exact bin probabilities for this model. Wall exclusion sets the interval accessible to centres. Define the specified cell height as that accessible interval.
Infer a mass with its sign
Use a radius of 0.50 µm, particle excess density 50 kg/m³ and temperature 293 K. The volume is \(5.236\times10^{-19}\) m³, the buoyant mass is \(2.618\times10^{-17}\) kg and \(k_BT/(m_bg)=15.75\) µm. Counts in two equal slices separated by 10 µm should have lower-to-upper ratio \(e^{10/15.75}\simeq1.89\). Doubling the radius at fixed density ratio multiplies the mass by eight and divides the gravitational length by eight.
Sampling is important when using the upper part of a steep profile. Suppose bins separated by 10 µm contain 120 and 60 approximately independent particle observations. The estimated slope is \(\ln(2)/10=0.0693\) µm⁻¹. For independent Poisson counts the standard error from propagating the two count variances is \(\sqrt{1/120+1/60}/10=0.0158\) µm⁻¹. Repeatedly imaging the same particle at closely spaced times introduces correlations. Counting all those frames as independent would make the quoted sampling precision too optimistic.
Open full-size diagram
Open full-size diagramExercise · determine the size of a density-matched particle
A uniform profile persists in a well-equilibrated, isothermal cell. Can gravity alone distinguish two different radii if the particles have the same density as the fluid?
Work through the solution
At exact density matching, \(m_b=V(\rho_p-\rho_f)=0\) for either radius, so both profiles are uniform. Their diffusion times can still differ because hydrodynamic mobility depends on size. A time-resolved measurement carries information absent from the equilibrium profile.
Exercise · reverse the measured gradient
Two equally wide slices separated vertically by 12 µm contain 80 and 160 observations, in order of increasing height. Estimate \(m_b\) at 293 K.
Work through the solution
The signed slope is \(\ln(80/160)/(12\ \mathrm{µm})=-0.05776\) µm⁻¹. Converting to metres and multiplying by \(k_BT/g\) gives \(m_b\simeq-2.38\times10^{-17}\) kg. The sign indicates that the displaced fluid is heavier than the particle.
Try it · Sedimentation
Change the inputs and compare the recalculated curves with the preceding derivation and baseline figure. The axes give the units; the numerical readout states the model assumptions and any limiting cases. Reset the inputs to return to the reference setting.
Download the corresponding editable notebook. The browser recalculates the reduced equations directly; the notebook exposes the full calculation and its checks.