Convert mechanical motion into a terminal admittance
A piezoelectric plate converts terminal voltage into force and velocity into current. With a linear reciprocal coupling coefficient \(n\), \(F=nV\) and \(I_m=nv\). The mechanical velocity impedance is \(b+i\omega m+k/(i\omega)\). Dividing it by \(n^2\) maps it to a series branch with \(R_m=b/n^2\), \(L_m=m/n^2\) and \(C_m=n^2/k\). The electrodes also have a static capacitance \(C_0\) in parallel. Thus
For negligible loss the series branch impedance vanishes at \(\omega_s=1/\sqrt{L_mC_m}\). Just above this frequency its susceptance is inductive and can cancel the parallel capacitance. Setting \(Y=0\) gives
With finite damping a peak and a dip replace the singular limits. Their extrema need not coincide exactly with the lossless frequencies.
Isolate the perturbation
A thin rigid deposit that changes only the effective mass multiplies \(L_m\) by \(1+\eta\). Both ideal frequencies scale as \((1+\eta)^{-1/2}\); their ratio is unchanged. Additional cable capacitance increases \(C_0\), changing the ratio while leaving the mechanical series frequency fixed. At a load fraction of 0.01 the expected series shift is about minus 0.496 percent. A viscoelastic deposit can also dissipate energy and alter stiffness, so the two-frequency test includes a physical assumption about the coating. For \(f_s=100.000\) kHz, \(C_m=0.25\) pF and \(C_0=15\) pF, the unloaded parallel frequency is 100.830 kHz. A 1% increase in effective mass puts the series resonance at 99.504 kHz. If the same shift came from extra cable capacitance alone, the series frequency would remain at 100.000 kHz. At quality factor 600 the approximate unloaded resonance linewidth is \(f_s/Q=167\) Hz. The predicted mass shift spans about three linewidths. The height of the peak by itself would confound damping and transduction.
Conversely, fit the two frequencies and infer the capacitance ratio as \((f_p/f_s)^2-1\). A small random error in \(f_p/f_s\) has a large relative effect on this estimate when the resonances nearly coincide. Zoom the frequency grid and compare the uncertainty from bin spacing with the shift under investigation.
Open full-size diagram
Open full-size diagramExercise · recover a capacitance ratio
A nearly lossless device gives \(f_p/f_s=1.01\). What ratio of motional to static capacitance is consistent with it?
Work through the solution
Squaring and subtracting one gives \(C_m/C_0=0.0201\). The difference between the squares matters when the shift is used for accurate capacitance inference.
Exercise · challenge a mass reading
After changing a fixture the dip moves but the series frequency remains within the experimental uncertainty. Does that support a pure mass increase?
Work through the solution
A purely inertial change shifts both resonance frequencies. The observed pattern is consistent with an increased shunt capacitance if the dip moved toward the series peak. A sweep of the linewidth and an independent capacitance check would test the model.
Try it · Piezo load
Change the inputs and compare the recalculated curves with the preceding derivation and baseline figure. The axes give the units; the numerical readout states the model assumptions and any limiting cases. Reset the inputs to return to the reference setting.
Download the corresponding editable notebook. The browser recalculates the reduced equations directly; the notebook exposes the full calculation and its checks.