Combine pressure flow and wall-driven flow before imposing continuity
Let \(x\) point along the moving surface from the wide inlet \(h_1\) to the thin outlet \(h_2\). The film has constant density and viscosity \(\mu\). It is shallow compared with its length \(L\), and the pad is broad enough to neglect side leakage. Local steady momentum balance is
Integrate across the gap with \(u(0)=U\) and \(u(h)=0\). The linear boundary-driven velocity combines with a parabolic pressure-driven term. Integration of that velocity gives the volume flow per unit width
The same \(q\) passes every station. Introduce \(h_*=2q/U\), making \(dp/dx=6\mu U(h-h_*)/h^3\). Equal ambient gauge pressures at both ends require the integral of the gradient over \(x\) to vanish. For a linearly tapering film convert integration from \(x\) to \(h\) and obtain \(h_*=2h_1h_2/(h_1+h_2)\). The pressure maximum lies where \(h=h_*\). Integrating once more gives a direct pressure profile:
This form subtracts nearby terms in nearly parallel gaps. The notebook uses the equivalent factored result \(p=6\mu U L(h_1-h_2)s(1-s)/[(h_1+h_2)h^2]\), where \(s=x/L\). It remains well behaved as the slope tends to zero.
Measure the pressure gradient where the Couette flux matches the actual flow
Choose inlet and outlet heights of 120 and 60 µm, length 40 mm, sliding speed 1 m/s and viscosity 0.050 Pa s. Then \(h_*=80\) µm and the flux per unit width is \(4.00\times10^{-5}\) m²/s. The pressure maximum is two thirds of the length from the inlet. For these data it is approximately 0.139 MPa. At that point the pressure-driven part of the flow vanishes locally even though the accumulated pressure above ambient is greatest. This is the distinction between a local gradient and an absolute load-carrying pressure.
Open full-size diagram
Open full-size diagramExercise · scale both clearances
Double inlet and outlet thickness while holding taper ratio, viscosity, length and speed fixed. What becomes of the pressure and the flow?
Work through the solution
The factor \((h_1-h_2)/(h_1+h_2)\) is constant, while the squared local height quadruples. Pressure and load per width fall to one quarter. The harmonic-mean height \(h_*\) doubles, so the through-flow doubles.
Exercise · interpret a reversed pad
What does the algebra predict for a diverging gap with the same wall direction? Under what condition does that extrapolation fail?
Work through the solution
The sign of \(h_1-h_2\) reverses, giving negative gauge pressure between the equal-pressure boundaries. Small subambient pressures can exist in a filled liquid. Once the absolute pressure reaches the cavitation threshold or gas enters the film, a full-film solution cannot represent the cavity or its mass balance. The notebook therefore keeps its default sweep in the converging regime.
Interactive calculation · Slider pressure
Change the physical and numerical inputs of the notebook model. Compare the updated curves and balance checks with the recorded notebook figures. Each plot uses the same equations and assumptions documented in that notebook; its readout names any analytical or reduced-model reference.
Interactive calculation · Slider flux
Change the physical and numerical inputs of the notebook model. Compare the updated curves and balance checks with the recorded notebook figures. Each plot uses the same equations and assumptions documented in that notebook; its readout names any analytical or reduced-model reference.