Magnetic diffusion into a conductor
A coil produces an alternating magnetic field next to a block of aluminium. Why does a probe just inside the surface see a larger signal than one several millimetres deeper? An increasing magnetic field induces an electric field. In a conductor this drives currents whose magnetic field opposes the change. Over a cycle the interior field both weakens and lags behind the surface field.
Let \(x\) be depth into a uniform stationary conductor, and let the magnetic field \(H_z(x,t)\) lie parallel to its flat surface. Assume constant conductivity \(\sigma\) and permeability \(\mu\). When \(\sigma\gg\omega\epsilon\), conduction current dominates displacement current. Ampère’s law gives
Ohm’s law gives
Substitute these into Faraday’s law \(\partial E_y/\partial x=-\mu\,\partial H_z/\partial t\) to obtain
The length scale selected by frequency
Impose \(H_z(0,t)=H_s\cos(\omega t)\) and take the conductor to extend to large positive \(x\). In sinusoidal steady state write \(H_z=\mathrm{Re}\{\hat H(x)e^{i\omega t}\}\). The diffusion equation becomes
Choosing the root that decays into the material gives
At one skin depth the amplitude is \(e^{-1}\) of its surface value and the phase lags by one radian. Since \(\hat J_y=-d\hat H/dx\), current density has the same decay length. This plane-surface approximation works near a curved surface when its radius of curvature and the distance to its far side are both large compared with \(\delta\).
Further study · Skin Effect (MIT OpenCourseWare demonstration).
A 5 kHz field in aluminium
Use \(\sigma=3.5\times10^7\,\mathrm{S/m}\) and \(\mu=\mu_0\approx4\pi\times10^{-7}\,\mathrm{H/m}\). Substitution of \(f=5000\,\mathrm{Hz}\) gives \(\delta=1.20\,\mathrm{mm}\). At \(x=3.0\,\mathrm{mm}\), the field amplitude is \(e^{-3.0/1.203}=0.083\) times the surface amplitude. A 2.0 mT surface signal gives about 0.17 mT there. The delay in phase is \(3.0/1.203=2.49\) radians, about 143°.
At 50 Hz the same metal has \(\delta=12.0\) mm. A cylinder of 10 mm radius then has no interior region many skin depths from the surface, so its axis and curvature must enter a quantitative calculation.
Tutorial · Attenuation and heating
At 5 kHz, how far into the planar block must one go for the field amplitude to reach 10% of its surface value? Repeat at 20 kHz.
Worked solution
Taking logarithms of \(e^{-x/\delta}=0.10\) gives
\[x=\delta\ln 10=2.77\,\mathrm{mm}.\]Quadrupling \(f\) halves \(\delta\), so the same attenuation occurs after 1.39 mm. For a semi-infinite block the fractional attenuation depends only on depth measured in skin depths.
Is more or less than half of the resistive heating produced in the first skin depth? Find the fraction, treating the surface as flat.
Worked solution
For peak current phasors the cycle-averaged heating per volume is \(|\hat J|^2/(2\sigma)\), so it varies with \(e^{-2x/\delta}\). Integrating from zero to \(\delta\) and dividing by the integral over all depths yields
\[1-e^{-2}=0.865.\]Roughly 86.5% of the heat is released in that first layer.
Numerical comparison · A cylindrical workpiece
A long coil with 1000 turns per metre and 2 A peak current surrounds an aluminium cylinder of radius 10 mm. At 50 Hz, 500 Hz and 5 kHz, the skin depths are respectively 12.0, 3.80 and 1.20 mm. Follow the computed radial field in that order and identify where the field begins to concentrate near the surface. Integrating the computed Joule heating over the cross-section gives 0.0406, 0.770 and 2.802 W per metre in the published case, checked against the cylindrical solution. Inspect the OneSimulation field and loss profiles.