To reproduce the case, put its notebook and accompanying inputs in the same folder. Use the Python environment set up in the installation tutorial. Start with the original parameters and compare the result with the check reported below.
Run this example yourself. The OneSimulation Runtime brings the full Python library and an MCP server for Codex and Claude Code. It starts with a seven-day trial, then from €19 per month before any applicable tax.

What it computes
OneSimulation couples two lumped thermal capacitances through a conductance and integrates them together.
What it checks
The temperature difference decays as exp(-G(1/C1+1/C2) t) and the weighted mean stays constant; within about 1e-8.
The notebook
The complete notebook, cell by cell. Run it to produce the figures and the comparison printout.
Two compact bodies with heat capacities \(C_1\) and \(C_2\) are connected by a thermal conductance \(G\) (for example a short metal bridge) and are otherwise perfectly insulated. Each body is small enough to stay uniform in temperature, so two lumped balances describe the system:
In OneSimulation each body is a lumped thermal capacitance whose "ambient" input is fed by the other body's temperature. The two models are coupled monolithically and integrated with the classical fourth-order Runge-Kutta method.
Reference. Adding the two balances shows that the total stored energy is conserved, so the capacity-weighted mean temperature
stays constant, while the temperature difference decays exponentially,
Both statements are checked at every stored time.
import numpy as np
from onesim.cad.geometry import LumpedDomain
from onesim.meshing import LumpedMesh
from onesim.numerics import Numerics
from onesim.numerics.coupled_systems import MonolithicCoupling
from onesim.numerics.discretization import LumpedParameters
from onesim.numerics.field_transfer import GlobalValueTransfer
from onesim.numerics.time import ClassicalRungeKutta4
from onesim.physics.systems import ThermalCapacitance
from onesim.results.storage import MemoryOutputSink, Output
from onesim.simulation import Problem, Simulation
from onesim.simulation.field_connections import FieldCoupling
from onesim.simulation.initial_conditions import InitialValue
from onesim.visualization import plots, theme
theme.set()Parameters and model
The parameters can be changed. The reference formulas below stay valid as long as the two heat capacities and the conductance are constant and no heat leaves the pair. The values describe a hot 1.3 kg copper block bolted to a cooler 1.7 kg aluminium block through a thin bridge.
heat_capacity_1 = 500.0
heat_capacity_2 = 1500.0
conductance = 2.0
initial_temperature_1 = 360.0
initial_temperature_2 = 300.0
decay_rate = conductance * (1.0 / heat_capacity_1 + 1.0 / heat_capacity_2)
time_constant = 1.0 / decay_rate
mean_temperature = (
heat_capacity_1 * initial_temperature_1 + heat_capacity_2 * initial_temperature_2
) / (heat_capacity_1 + heat_capacity_2)
end_time = 4.0 * time_constant
time_step = 0.02 * time_constant
print(
f"time constant 1/(G(1/C1+1/C2)) = {time_constant:.1f} s, final temperature = {mean_temperature:.2f} K"
)
domain = LumpedDomain()
body_1 = ThermalCapacitance(
domain=domain.system,
heat_capacity=heat_capacity_1,
conductance=conductance,
ambient_temperature=None,
heating=0.0,
)
body_2 = ThermalCapacitance(
domain=domain.system,
heat_capacity=heat_capacity_2,
conductance=conductance,
ambient_temperature=None,
heating=0.0,
)
problem = Problem(
name="Two thermal masses exchanging heat",
geometry=domain,
physics=(body_1, body_2),
initial_conditions=(
InitialValue(body_1.temperature, initial_temperature_1),
InitialValue(body_2.temperature, initial_temperature_2),
),
couplings=(
FieldCoupling(
source=body_2.temperature,
target=body_1.ambient,
transfer=GlobalValueTransfer(),
),
FieldCoupling(
source=body_1.temperature,
target=body_2.ambient,
transfer=GlobalValueTransfer(),
),
),
)
numerics = Numerics(spatial=LumpedParameters())
simulation = Simulation(
problem=problem,
mesh={body_1: LumpedMesh(domain), body_2: LumpedMesh(domain)},
numerics={body_1: numerics, body_2: numerics},
coupling_solver=MonolithicCoupling(
transient_systems=(body_1, body_2),
time_integrator=ClassicalRungeKutta4(),
),
)
simulation.validate().require_valid()
sink = MemoryOutputSink()
result = simulation.run(
start_time=0.0,
end_time=end_time,
time_step=time_step,
output=Output(
fields=(body_1.temperature, body_2.temperature),
interval=time_step,
sink=sink,
),
)
times = sink.times
temperatures_1 = sink.time_series(body_1.temperature)[1]
temperatures_2 = sink.time_series(body_2.temperature)[1]Comparison with the closed-form solution
We check the exponential decay of the temperature difference and the constancy of the capacity-weighted mean at every stored time. A passing check shows that this numerical example agrees with the two-node balance; it is not a measurement of real blocks.
difference = temperatures_1 - temperatures_2
reference_difference = (initial_temperature_1 - initial_temperature_2) * np.exp(
-decay_rate * times
)
max_difference_error = float(np.max(np.abs(difference - reference_difference)))
weighted_mean = (
heat_capacity_1 * temperatures_1 + heat_capacity_2 * temperatures_2
) / (heat_capacity_1 + heat_capacity_2)
max_mean_drift = float(np.max(np.abs(weighted_mean - mean_temperature)))
print(f"Maximum error of the temperature difference: {max_difference_error:.3e} K")
print(f"Maximum drift of the capacity-weighted mean: {max_mean_drift:.3e} K")Each temperature individually follows from the two invariants. Recover the decay rate from the log-slope of the difference.
fitted_rate = -np.polyfit(times, np.log(difference), 1)[0]
print(
f"Decay rate: fitted {fitted_rate:.6f} 1/s, exact G(1/C1+1/C2) = {decay_rate:.6f} 1/s"
)Figure
dense_t = np.linspace(0.0, end_time, 400)
dense_diff = (initial_temperature_1 - initial_temperature_2) * np.exp(
-decay_rate * dense_t
)
total_capacity = heat_capacity_1 + heat_capacity_2
fig = plots.figure(2, 1, size=(8, 7))
plots.line(
points={
"body 1": (times[::4], temperatures_1[::4]),
"body 2": (times[::4], temperatures_2[::4]),
},
reference={
"body 1": (
dense_t,
mean_temperature + heat_capacity_2 / total_capacity * dense_diff,
),
"body 2": (
dense_t,
mean_temperature - heat_capacity_1 / total_capacity * dense_diff,
),
},
hlines={"capacity-weighted mean": mean_temperature},
ylabel="temperature [K]",
title="Two thermal masses: OneSimulation (markers) and closed form (dashed)",
legend="center right",
ax=fig[0],
)
plots.line(
points={"OneSimulation T_1 - T_2": (times[::4], difference[::4])},
reference={"exponential decay": (dense_t, dense_diff)},
scale="logy",
xlabel="time [s]",
ylabel="temperature difference [K]",
ax=fig[1],
)
plots.show()Going further
Make the two heat capacities equal and confirm that the final temperature is the arithmetic mean. Give one body a constant heating power and the pair then warms without bound at the rate \(P/(C_1+C_2)\) on top of the decaying difference; or add a third body to build a small thermal network. In each case write down the new reference before changing the checks.