To reproduce the case, put its notebook and accompanying inputs in the same folder. Use the Python environment set up in the installation tutorial. Start with the original parameters and compare the result with the check reported below.
Run this example yourself. The OneSimulation Runtime brings the full Python library and an MCP server for Codex and Claude Code. It starts with a seven-day trial, then from €19 per month before any applicable tax.

What it computes
OneSimulation solves the steady SpeciesTransport balance with binary diffusivities on finite volumes along the tube axis; stagnant_species declares air at rest, so the model determines the Stefan flow and the total concentration itself, and Newton's method with the exact tangent converges in a few iterations.
What it checks
The evaporation fluxes converge at second order to the exact solution (1.4e-5 and 1.0e-5 relative deviation on 160 cells) and lie 0.17 % above the Carty-Schrodt measurements; the composition profiles match the exact matrix-exponential profile within 2.4e-5, the air flux is zero and bottom and top fluxes agree to 1e-16.
The notebook
The complete notebook, cell by cell. Run it to produce the figures and the comparison printout.
The tube of length \(L=0.238\) m holds a liquid acetone (1) and methanol (2) mixture at the bottom (\(z=0\)); air (3) flows over the open top (\(z=L\)). At 328.5 K and 99.4 kPa the total molar concentration is \(c=36.375\) mol/m³. The molar fluxes \(N_i\) obey the steady balances and the Maxwell-Stefan relations
The last condition is the stagnant air: it fixes the molar-average velocity \(u=(N_1+N_2)/c\), so no velocity has to be prescribed. OneSimulation's SpeciesTransport with the binary diffusivities \(D_{ij}\) solves the coupled Maxwell-Stefan fluxes on finite volumes; stagnant_species="air" makes the model determine the Stefan flow itself and close the total concentration with air.
| Quantity | Value |
|---|---|
| \(D_{12}\) acetone-methanol | \(8.48\cdot10^{-6}\) m²/s |
| \(D_{13}\) acetone-air | \(13.72\cdot10^{-6}\) m²/s |
| \(D_{23}\) methanol-air | \(19.91\cdot10^{-6}\) m²/s |
| liquid surface, \(z=0\) | \(x_1=0.319\), \(x_2=0.528\), \(x_3=0.153\) |
| open top, \(z=L\) | pure air |
Reference. Ternary evaporation experiment of R. Carty and T. Schrodt, Ind. Eng. Chem. Fundam. 14 (1975) 276 (run T-5): measured fluxes \(N_1=1.779\cdot10^{-3}\) and \(N_2=3.121\cdot10^{-3}\) mol/(m² s) and seven measured composition points. The exact solution of the one-dimensional problem, computed independently by integrating the Maxwell-Stefan relations and shooting the two fluxes onto the top composition (the method of R. Taylor and R. Krishna, Multicomponent Mass Transfer, Wiley 1993, §2.2), gives \(N_1=1.78213\cdot10^{-3}\) and \(N_2=3.12645\cdot10^{-3}\) mol/(m² s). For given fluxes the composition along the tube is linear in \(x_1, x_2\) with constant coefficients,
so the exact profile is a matrix exponential, and it must reach pure air at the top.
import numpy as np
from onesim.cad.d1 import Line
from onesim.meshing import StructuredLineMesher
from onesim.numerics import Numerics
from onesim.numerics.fvm import CentralDifference, FiniteVolume, LeastSquaresGradient
from onesim.numerics.linear import SparseDirect
from onesim.numerics.nonlinear import Newton
from onesim.physics.chemistry import (
FixedConcentration,
SpeciesTransport,
TransportSpecies,
)
from onesim.simulation import Problem, Simulation
from onesim.visualization import plots, theme
from scipy.linalg import expm
theme.set()Model
The tube axis is a line; the bottom carries the composition in equilibrium with the liquid, the top pure air. The lateral wall needs no condition in one dimension.
length, total = 0.238, 36.375
names = ("acetone", "methanol", "air")
d12, d13, d23 = 8.48e-6, 13.72e-6, 19.91e-6
liquid_surface = np.array([0.319, 0.528, 0.153])
open_top = np.array([0.0, 0.0, 1.0])
tube = Line(start=(0.0, 0.0, 0.0), end=(length, 0.0, 0.0))
mixture = SpeciesTransport(
domain=tube.line,
species=tuple(TransportSpecies(name) for name in names),
binary_diffusivities=((0.0, d12, d13), (d12, 0.0, d23), (d13, d23, 0.0)),
stagnant_species="air",
)
problem = Problem(
name="Stefan tube",
geometry=tube,
physics=(mixture,),
boundary_conditions=(
FixedConcentration(
physics=mixture,
boundary=tube.boundaries.start,
value=dict(zip(names, total * liquid_surface)),
),
FixedConcentration(
physics=mixture,
boundary=tube.boundaries.end,
value=dict(zip(names, total * open_top)),
),
),
)
numerics = Numerics(
spatial=FiniteVolume(
gradient=LeastSquaresGradient(), diffusion=CentralDifference()
),
nonlinear_solver=Newton(linear_solver=SparseDirect(), absolute_tolerance=1e-12),
)Steady state on five meshes
The steady problem is solved directly with Newton's method on 10 to 160 cells. The fluxes are the outward boundary fluxes of each species at the open top (per unit cross section).
meshes = (10, 20, 40, 80, 160)
results = {
cells: Simulation(
problem=problem,
mesh=StructuredLineMesher(cells=cells).generate(tube),
numerics=numerics,
).solve_stationary()
for cells in meshes
}
fluxes = {
cells: np.array(
[
result.field(mixture.field(name)).boundary_flux(tube.boundaries.end)
for name in names
]
)
for cells, result in results.items()
}Comparison of the fluxes
The evaporation fluxes against the exact solution and the measurement; the air flux and the balance between bottom and top show the stagnant gas and the conservation of the scheme.
exact = np.array([1.78213e-3, 3.12645e-3])
measured = np.array([1.779e-3, 3.121e-3])
print(
" cells N acetone [mol/m²s] N methanol [mol/m²s] deviation from exact N air [mol/m²s]"
)
for cells, flux in fluxes.items():
print(
f"{cells:6d} {flux[0]:19.6e} {flux[1]:21.6e} {flux[0] / exact[0] - 1:+9.1e} {flux[1] / exact[1] - 1:+9.1e} {flux[2]:15.1e}"
)
finest = results[meshes[-1]]
inflow = np.array(
[
finest.field(mixture.field(name)).boundary_flux(tube.boundaries.start)
for name in names
]
)
print(
f"bottom and top fluxes agree to {np.max(np.abs(inflow + fluxes[meshes[-1]])):.1e} mol/m²s"
)
print(
f"deviation from the measured fluxes: acetone {fluxes[meshes[-1]][0] / measured[0] - 1:+.2%}, "
f"methanol {fluxes[meshes[-1]][1] / measured[1] - 1:+.2%}"
)
print(
f"Stefan flow: molar-average velocity (N1 + N2)/c = {fluxes[meshes[-1]][:2].sum() / total * 1e3:.4f} mm/s"
)Comparison of the profiles
With the computed fluxes the matrix exponential gives the exact composition along the tube; it must arrive at pure air at the top. The measured compositions of Carty and Schrodt are shown as well.
n1, n2 = fluxes[meshes[-1]][:2]
generator = (
np.array(
[
[n2 / d12 + n1 / d13, n1 / d13 - n1 / d12, -n1 / d13],
[n2 / d23 - n2 / d12, n1 / d12 + n2 / d23, -n2 / d23],
[0.0, 0.0, 0.0],
]
)
/ total
)
heights = np.linspace(0.0, length, 121)
profile = np.array(
[expm(generator * z) @ np.r_[liquid_surface[:2], 1.0] for z in heights]
)[:, :2]
print(
f"exact profile with the computed fluxes reaches x1 = {profile[-1, 0]:.1e}, x2 = {profile[-1, 1]:.1e} at the top"
)
measured_height = 0.01 * np.array([4.45, 7.0, 9.45, 11.9, 14.4, 17.0, 19.4])
measured_acetone = np.array([0.263, 0.251, 0.232, 0.217, 0.185, 0.153, 0.113])
measured_methanol = np.array([0.457, 0.460, 0.421, 0.379, 0.307, 0.243, 0.168])
centres = {
cells: np.asarray(result.field(mixture.field("air")).space.dof_coordinates)[:, 0]
for cells, result in results.items()
}
fractions = {
cells: np.stack(
[np.asarray(result.field(mixture.field(name)).values) for name in names]
)
/ total
for cells, result in results.items()
}
print(
" cells largest profile deviation acetone methanol air sum of mole fractions - 1"
)
for cells in meshes:
reference = np.array(
[np.interp(centres[cells], heights, profile[:, k]) for k in range(2)]
)
reference = np.vstack((reference, 1 - reference.sum(axis=0)))
print(
f"{cells:6d} {np.max(np.abs(fractions[cells][0] - reference[0])):27.1e} {np.max(np.abs(fractions[cells][1] - reference[1])):10.1e} "
f"{np.max(np.abs(fractions[cells][2] - reference[2])):8.1e} {np.max(np.abs(fractions[cells].sum(axis=0) - 1)):18.1e}"
)
rms = [
np.sqrt(
np.mean(
(
np.interp(
measured_height, centres[meshes[-1]], fractions[meshes[-1]][k]
)
- data
)
** 2
)
)
for k, data in enumerate((measured_acetone, measured_methanol))
]
print(
f"root-mean-square deviation from the measured compositions: acetone {rms[0]:.4f}, methanol {rms[1]:.4f}"
)Figure
Left: the three mole fractions along the tube on 20 cells (solid), the exact profile (dashed) and the measured points. Near the liquid the methanol profile is almost flat although methanol carries the larger flux: the Stefan flow and the friction with the acetone flux do part of its transport, a coupling that a Fick law with one diffusivity per species cannot show. The measured acetone fractions lie about 0.03 below both the computed and the exact profile, so this offset stems from the experiment or the property data, not from the discretisation. Right: the flux deviation from the exact solution over the cell size, with second-order convergence.
fig = plots.figure(1, 2, size=(15, 5.5))
plots.line(
y={
"acetone": (100 * centres[20], fractions[20][0]),
"methanol": (100 * centres[20], fractions[20][1]),
"air": (100 * centres[20], fractions[20][2]),
},
points={
"measured acetone": (100 * measured_height, measured_acetone),
"measured methanol": (100 * measured_height, measured_methanol),
},
reference={
"acetone": (100 * heights, profile[:, 0]),
"methanol": (100 * heights, profile[:, 1]),
"air": (100 * heights, 1 - profile.sum(axis=1)),
},
colors={"measured acetone": 0, "measured methanol": 1},
xlabel="height above the liquid z [cm]",
ylabel="mole fraction",
title="Composition in the tube (dashed: exact, circles: measured)",
legend="upper left",
ax=fig[0],
)
plots.line(
points={
"acetone": (
np.array([length / cells for cells in meshes]),
np.array([abs(fluxes[cells][0] / exact[0] - 1) for cells in meshes]),
),
"methanol": (
np.array([length / cells for cells in meshes]),
np.array([abs(fluxes[cells][1] / exact[1] - 1) for cells in meshes]),
),
},
markers=True,
scale="loglog",
slope=2,
xlabel="cell size [m]",
ylabel="relative flux deviation",
title="Mesh convergence of the evaporation fluxes",
legend="lower right",
ax=fig[1],
)
plots.show()Going further
The same declaration runs on the revolved r-z section of the tube (RevolvedCellMeshView in FiniteVolume) and on a three-dimensional tube; the fluxes then come out per tube rather than per unit area. With two species it reduces to the binary Stefan problem, \(N_A=\frac{cD}{L}\ln\frac{1-x_{A,L}}{1-x_{A,0}}\). With initial values and a time integrator the same model computes the start-up of the evaporation from a tube initially filled with air.