To reproduce the case, put its notebook and accompanying inputs in the same folder. Use the Python environment set up in the installation tutorial. Start with the original parameters and compare the result with the check reported below.
Run this example yourself. The OneSimulation Runtime brings the full Python library and an MCP server for Codex and Claude Code. It starts with a seven-day trial, then from €19 per month before any applicable tax.

What it computes
OneSimulation couples a lumped battery for state of charge, open-circuit voltage, series resistance and self-discharge with an electrical circuit for the RC polarisation, which enters the cell as an additional voltage drop. The same parameters give the small-signal impedance through the battery impedance model, and a 30-day storage test runs at 0, 25 and 45 °C.
What it checks
The RC-branch voltage matches the closed-form step response to 0.09 mV, the terminal voltage to within the same margin and the state of charge coulomb counting to 1e-4; the impedance read from sinusoidal circuit runs agrees with the impedance model to 1e-4 mOhm at five frequencies, and the storage loss equals the Arrhenius closed form at all three temperatures.
The notebook
The complete notebook, cell by cell. Run it to produce the figures and the comparison printout.
Equivalent-circuit models describe a cell by what is measured at its terminals. Here a voltage source \(U_\mathrm{oc}(s)\) that depends on the state of charge \(s\), a series resistance \(R_0\) and one RC branch for the charge-transfer and diffusion polarisation \(u_1\):
NiMH cells lose charge on the shelf through internal side reactions; the self-discharge current follows an Arrhenius law \(I_\mathrm{sd}=k_\mathrm{ref}\,Q\,\exp\!\big[-\tfrac{E_a}{R}\big(\tfrac1T-\tfrac1{T_\mathrm{ref}}\big)\big]\). The open-circuit curve is a Nernst-type curve around 1.28 V.
In OneSimulation the cell is a lumped battery (state of charge, voltage source, series resistance, self-discharge as internal charge loss) and the RC branch is an electrical circuit driven by the same current; the branch voltage enters the cell as an additional voltage drop. The small-signal impedance of the same parameters is a battery impedance model.
Reference. The closed-form solution of the linear circuit: for a piecewise constant current with steps \(\Delta I_k\) at \(t_k\), \(u_1(t)=\sum_k\Delta I_kR_1\big(1-e^{-(t-t_k)/\tau_1}\big)\) with \(\tau_1=R_1C_1\); the impedance \(Z(\omega)=R_0+R_1/(1+i\omega\tau_1)\); and the linear loss of state of charge \(I_\mathrm{sd}t/Q\) in storage. Model structure and parameter ranges as in G. L. Plett, Battery Management Systems, Vol. I: Battery Modeling (Artech House, 2015).
import numpy as np
from onesim.cad.geometry import LumpedDomain
from onesim.meshing import LumpedMesh
from onesim.numerics import Numerics
from onesim.numerics.discretization import LumpedParameters
from onesim.numerics.time import ClassicalRungeKutta4
from onesim.physics.chemistry import (
BatteryChemistry,
BatteryImpedance,
BatteryRelaxationBranch,
LumpedBattery,
)
from onesim.physics.systems import (
Circuit,
CircuitCapacitor,
CircuitCurrentSource,
CircuitResistor,
)
from onesim.results.storage import MemoryOutputSink, Output
from onesim.simulation import Problem, Simulation
from onesim.simulation.initial_conditions import InitialValue
from onesim.visualization import plots, theme
theme.set()Cell parameters
A 2.5 Ah cell; self-discharge of 20 % per month at 25 °C with an activation energy of 35 kJ/mol.
capacity, r0, r1, tau1 = 2.5 * 3600, 0.020, 0.015, 40.0
k_ref, activation, gas = 0.20 / (30 * 86400), 35e3, 8.314462618
open_circuit = lambda s: 1.28 + 0.08 * (s - 0.5) + 0.012 * np.log(s / (1 - s))
self_discharge = (
lambda T: k_ref * capacity * np.exp(-activation / gas * (1 / T - 1 / 298.15))
)
chemistry = BatteryChemistry(
"nimh",
open_circuit_voltage=lambda s, T: open_circuit(s),
internal_resistance=lambda s, T: r0,
)
impedance = BatteryImpedance(
series_resistance=r0,
branches=(BatteryRelaxationBranch(resistance=r1, relaxation_time=tau1),),
)Pulse discharge
From 90 % state of charge: 10 min at 1C, 10 min rest, 5 min at 2C, 15 min rest, 2 min of 1C charge and 8 min rest, at 25 °C. The circuit is integrated with the trapezoidal rule at 0.1 s steps.
steps = np.array(
[(0, 2.5), (600, 0.0), (1200, 5.0), (1500, 0.0), (2400, -2.5), (2520, 0.0)]
)
load = lambda t: steps[np.searchsorted(steps[:, 0], t, side="right") - 1, 1]
times = np.arange(0.0, 3001.0, 1.0)
branch = Circuit(
components=(
CircuitCurrentSource(name="load", positive="0", negative="rc", current=load),
CircuitResistor(name="r1", positive="rc", negative="0", resistance=r1),
CircuitCapacitor(
name="c1",
positive="rc",
negative="0",
capacitance=tau1 / r1,
initial_voltage=0.0,
),
)
).solve(times=times, max_step=0.1)
polarisation = branch.voltages["rc"]
cell = LumpedDomain()
model = LumpedBattery(
domain=cell.system,
chemistry=chemistry,
charge_capacity=capacity,
current=load,
thermal_capacity=40.0,
heat_transfer=0.05,
ambient_temperature=298.15,
effects={
"internal_charge_loss": self_discharge(298.15),
"additional_voltage_drop": lambda t: np.interp(t, times, polarisation),
},
)
problem = Problem(
name="NiMH pulse test",
geometry=cell,
physics=(model,),
initial_conditions=(
InitialValue(model.state_of_charge, 0.9),
InitialValue(model.temperature, 298.15),
),
)
numerics = Numerics(spatial=LumpedParameters(), time_integrator=ClassicalRungeKutta4())
record = MemoryOutputSink()
Simulation(problem=problem, mesh=LumpedMesh(cell), numerics=numerics).run(
start_time=0.0,
end_time=3000.0,
time_step=1.0,
output=Output(
fields=(model.state_of_charge, model.terminal_voltage, model.temperature),
interval=1.0,
sink=record,
),
)
soc, voltage, temperature = (
record.time_series(field)[1]
for field in (model.state_of_charge, model.terminal_voltage, model.temperature)
)Impedance spectrum and storage
The circuit is driven by a sinusoidal current of 0.1 A at five frequencies, starting on the periodic solution; amplitude and phase of the response give the impedance. The storage test keeps the cell at rest for 30 days at 0, 25 and 45 °C.
frequencies = np.array([1e-3, 4e-3, 1e-2, 4e-2, 1e-1])
sine = {
f: Circuit(
components=(
CircuitCurrentSource(
name="load",
positive="0",
negative="rc",
current=lambda t, f=f: 0.1 * np.cos(2 * np.pi * f * t),
),
CircuitResistor(name="r1", positive="rc", negative="0", resistance=r1),
CircuitCapacitor(
name="c1",
positive="rc",
negative="0",
capacitance=tau1 / r1,
initial_voltage=(0.1 * r1 / (1 + 2j * np.pi * f * tau1)).real,
),
)
).solve(times=np.linspace(0, 1 / f, 401), max_step=1 / (400 * f))
for f in frequencies
}
measured = {
f: r0
+ 2
* np.mean(run.voltages["rc"][:-1] * np.exp(-2j * np.pi * f * run.times[:-1]))
/ 0.1
for f, run in sine.items()
}
storage = {}
for celsius in (0, 25, 45):
shelf = LumpedBattery(
domain=cell.system,
chemistry=chemistry,
charge_capacity=capacity,
current=0.0,
thermal_capacity=40.0,
heat_transfer=0.05,
ambient_temperature=273.15 + celsius,
effects={"internal_charge_loss": self_discharge(273.15 + celsius)},
)
shelf_record = MemoryOutputSink()
Simulation(
problem=Problem(
name="NiMH storage",
geometry=cell,
physics=(shelf,),
initial_conditions=(
InitialValue(shelf.state_of_charge, 0.9),
InitialValue(shelf.temperature, 273.15 + celsius),
),
),
mesh=LumpedMesh(cell),
numerics=numerics,
).run(
start_time=0.0,
end_time=30 * 86400.0,
time_step=3600.0,
output=Output(
fields=(shelf.state_of_charge, shelf.terminal_voltage),
interval=86400.0,
sink=shelf_record,
),
)
storage[celsius] = (
shelf_record.times,
shelf_record.time_series(shelf.state_of_charge)[1],
shelf_record.time_series(shelf.terminal_voltage)[1],
)Results
exact_rc = sum(
np.where(times >= t_k, dI * r1 * (1 - np.exp(-(times - t_k) / tau1)), 0.0)
for t_k, dI in zip(steps[:, 0], np.diff(np.r_[0.0, steps[:, 1]]))
)
charge = np.r_[0.0, np.cumsum([load(t) for t in times[:-1]])]
exact_soc = 0.9 - (charge + self_discharge(298.15) * times) / capacity
exact_voltage = (
open_circuit(exact_soc) - r0 * np.array([load(t) for t in times]) - exact_rc
)
print(
f"branch voltage against the closed form: largest deviation {1e3 * np.abs(polarisation - exact_rc).max():.3f} mV "
f"(peak {1e3 * polarisation.max():.1f} mV); KCL residual {np.abs(branch.kcl_residual).max():.1e} A"
)
print(
f"state of charge against coulomb counting: {np.abs(soc - exact_soc[record.times.astype(int)]).max():.1e}; "
f"terminal voltage against the closed form: {1e3 * np.abs(voltage - exact_voltage[record.times.astype(int)]).max():.3f} mV"
)
print(f"temperature rise in the 2C pulse {temperature.max() - 298.15:.3f} K")
print(
"frequency [Hz] Z from the circuit [mΩ] Z of the impedance model [mΩ] |difference| [mΩ]"
)
for f, z in measured.items():
exact = impedance.spectrum(f)
print(
f"{f:14.3g} {1e3 * z.real:8.3f} {1e3 * z.imag:+8.3f}i {1e3 * exact.real:8.3f} {1e3 * exact.imag:+8.3f}i {1e3 * abs(z - exact):12.2e}"
)
for celsius, (t, s, v) in storage.items():
print(
f"storage at {celsius:2d} °C: state of charge after 30 days {s[-1]:.4f}, closed form {0.9 - self_discharge(273.15 + celsius) * t[-1] / capacity:.4f}, "
f"open-circuit voltage {v[0]:.4f} -> {v[-1]:.4f} V"
)Figure
fig = plots.figure(2, 2, size=(14, 10))
plots.line(
times / 60,
{"simulation": voltage},
reference={"closed form": exact_voltage},
right={"current [A]": np.array([load(t) for t in times])},
xlabel="time [min]",
ylabel="terminal voltage [V]",
right_label="current [A]",
title="Pulse test at 25 °C",
legend="lower left",
ax=fig[0],
)
plots.line(
times / 60,
{"circuit": 1e3 * polarisation},
reference={"closed form": 1e3 * exact_rc},
xlabel="time [min]",
ylabel="RC-branch voltage u₁ [mV]",
title="Polarisation of the RC branch",
legend="upper right",
ax=fig[1],
)
spectrum = impedance.spectrum(np.geomspace(1e-4, 10, 300))
plots.line(
1e3 * spectrum.real,
{"impedance model": -1e3 * spectrum.imag},
points={
"time-domain circuit": (
1e3 * np.array([z.real for z in measured.values()]),
-1e3 * np.array([z.imag for z in measured.values()]),
)
},
xlabel="Re Z [mΩ]",
ylabel="-Im Z [mΩ]",
title="Impedance (Nyquist)",
legend="upper right",
ax=fig[2],
)
plots.line(
points={
f"{celsius} °C": (t[::2] / 86400, s[::2])
for celsius, (t, s, v) in storage.items()
},
reference={
f"{celsius} °C": (
t / 86400,
0.9 - self_discharge(273.15 + celsius) * t / capacity,
)
for celsius, (t, s, v) in storage.items()
},
xlabel="storage time [days]",
ylabel="state of charge",
title="Self-discharge on the shelf (dashed: closed form)",
legend="lower left",
ax=fig[3],
)
plots.show()Going further
Add a second RC branch for the slow diffusion, let the self-discharge depend on the state of charge, or fit \(R_0\), \(R_1\) and \(\tau_1\) to a measured spectrum with the impedance model.