Newton cooling of a thermal mass
Newton cooling of a thermal mass. Run the notebook to produce its own figures.

What it computes

OneSimulation integrates a lumped (0D) thermal-mass balance C dT/dt = -hA(T-T_inf) in time.

What it checks

Compared with T(t)=T_inf+(T0-T_inf) e^{-hA t/C} at every stored time; within about 1e-6.

The notebook

The complete notebook, cell by cell. Run it to produce the figures and the comparison printout.

A compact body with total heat capacity \(C\) sits in a still environment at temperature \(T_\infty\) and loses heat through its surface by convection. When the body is small enough that its interior stays nearly uniform (the lumped-capacitance limit), a single temperature \(T(t)\) describes it and Newton's law of cooling holds:

\[C\,\frac{dT}{dt}=-h\,A\,(T-T_\infty).\]

Here \(h\) is the convective heat-transfer coefficient and \(A\) the exposed area; the product \(hA\) is the thermal conductance to the surroundings. OneSimulation treats this as a zero-dimensional (lumped) model and integrates it in time with the classical fourth-order Runge-Kutta method.

Reference. Separating variables gives the exponential decay towards the ambient temperature,

\[T(t)=T_\infty+(T_0-T_\infty)\,e^{-hA\,t/C},\]

with time constant \(\tau=C/(hA)\). We compare every stored time against this expression.

import numpy as np
from onesim.cad.geometry import LumpedDomain
from onesim.meshing import LumpedMesh
from onesim.numerics import Numerics
from onesim.numerics.discretization import LumpedParameters
from onesim.numerics.time import ClassicalRungeKutta4
from onesim.physics.systems import ThermalCapacitance
from onesim.results.storage import MemoryOutputSink, Output
from onesim.simulation import Problem, Simulation
from onesim.simulation.initial_conditions import InitialValue
from onesim.visualization import plots, theme

theme.set()

Parameters and model

The parameters can be changed. The reference formula below stays valid as long as the heat capacity, area, heat-transfer coefficient and ambient temperature are constant. The values describe a small metal part cooling in quiet air.

heat_capacity = 900.0
heat_transfer_coefficient = 15.0
area = 0.06
ambient_temperature = 300.0
initial_temperature = 350.0

conductance = heat_transfer_coefficient * area
time_constant = heat_capacity / conductance
end_time = 3.0 * time_constant
time_step = 0.05 * time_constant
print(
    f"conductance hA = {conductance:.3f} W/K,  time constant C/(hA) = {time_constant:.1f} s"
)

domain = LumpedDomain()
model = ThermalCapacitance(
    domain=domain.system,
    heat_capacity=heat_capacity,
    conductance=conductance,
    ambient_temperature=ambient_temperature,
    heating=0.0,
)
simulation = Simulation(
    problem=Problem(
        name="Convective cooling of a lumped thermal mass",
        geometry=domain,
        physics=(model,),
        initial_conditions=(InitialValue(model.temperature, initial_temperature),),
    ),
    mesh=LumpedMesh(domain),
    numerics=Numerics(
        spatial=LumpedParameters(),
        time_integrator=ClassicalRungeKutta4(),
    ),
)
simulation.validate().require_valid()

sink = MemoryOutputSink()
result = simulation.run(
    start_time=0.0,
    end_time=end_time,
    time_step=time_step,
    output=Output(fields=(model.temperature,), interval=time_step, sink=sink),
)
times, temperatures = sink.time_series(model.temperature)

Comparison with the closed-form solution

We evaluate the exponential reference at every stored time. A passing check shows that this numerical example agrees with Newton's law of cooling; it is not an experimental validation of a real object.

reference = ambient_temperature + (initial_temperature - ambient_temperature) * np.exp(
    -conductance * times / heat_capacity
)
max_abs_error = float(np.max(np.abs(temperatures - reference)))
print("Error per stored time (K):")
for t, err in zip(times, np.abs(temperatures - reference)):
    print(f"  t={t:7.1f} s  |dT|={err:.3e} K")
print(f"Maximum absolute error against the exponential: {max_abs_error:.3e} K")

Figure

dense_t = np.linspace(0.0, end_time, 400)
plots.line(
    points={"OneSimulation RK4": (times, temperatures)},
    reference={
        "Newton's law of cooling": (
            dense_t,
            ambient_temperature
            + (initial_temperature - ambient_temperature)
            * np.exp(-conductance * dense_t / heat_capacity),
        )
    },
    hlines={"ambient": ambient_temperature},
    xlabel="time [s]",
    ylabel="temperature [K]",
    title="Convective cooling of a lumped thermal mass",
)
plots.show()

Going further

Halve the time step and confirm that the error against the exponential shrinks as expected for a fourth-order method. Then vary the conductance \(hA\) or the heat capacity \(C\) and relate the change in the time constant \(\tau=C/(hA)\) to the equation. Adding a constant internal power through the heating input turns the body towards a shifted steady state \(T_\infty+P/(hA)\) instead of the ambient temperature; replace the reference accordingly before studying that case.