Application Library / Chemistry

Power losses of a lithium-ion cell in a hybrid pulse power test

A 5 Ah graphite-SiOx | NMC811 cell runs through a hybrid pulse power test at 80, 50 and 20 % state of charge, and every watt it loses is traced to its origin.

To reproduce the case, put its notebook and accompanying inputs in the same folder. Use the Python environment set up in the installation tutorial. Start with the original parameters and compare the result with the check reported below.

Doyle-Fuller-NewmanHPPC testLoss breakdownEnergy balance

Run this example yourself. The OneSimulation Runtime brings the full Python library and an MCP server for Codex and Claude Code. It starts with a seven-day trial, then from €19 per month before any applicable tax.

Start the 7-day trial Compare the plans

Power losses of a lithium-ion cell in a hybrid pulse power test
Power losses of a lithium-ion cell in a hybrid pulse power test. Run the notebook to produce its own figures.

What it computes

OneSimulation solves the Doyle-Fuller-Newman porous-electrode model for 10 s discharge and regenerative pulses with rests and 1C steps in between. From the solution fields the dissipated power is split into electrolyte conduction, salt concentration, electrode conduction, reaction and particle diffusion losses.

What it checks

The five parts add up to the terminal power loss against the open-circuit voltage of the mean stoichiometries to 2e-10 W/m² at every output time and to all printed digits of the pulse energies (14.76, 14.46 and 14.82 J per discharge pulse); the reaction contributes 59 to 73 %, particle diffusion 7 to 18 %, electrolyte conduction about 14 %, electrode conduction 5 % and salt concentration 2 to 4 %.

The notebook

The complete notebook, cell by cell. Run it to produce the figures and the comparison printout.

The hybrid pulse power characterisation (HPPC) test probes a cell with a 10 s discharge pulse, 40 s rest and a 10 s regenerative charge pulse at 75 % of the discharge current, repeated at several states of charge. Every watt the cell does not deliver is turned into heat somewhere inside it. With the Doyle-Fuller-Newman model (equations in the discharge-rest-charge example) the loss of terminal power against the reversible power of the mean electrode stoichiometries splits exactly into five parts:

\[I\big(U_+(\bar\theta_+)-U_-(\bar\theta_-)\big)-IV= \underbrace{\int\frac{i_e^2}{\kappa}dx}_{\text{electrolyte conduction}} \underbrace{-\int i_e\frac{2(1-t_+)RT}{F}\frac{\partial\ln c_e}{\partial x}dx}_{\text{salt concentration}} +\underbrace{\int\frac{i_s^2}{\sigma}dx}_{\text{electrode conduction}} +\underbrace{\int a\,j\,\eta\,dx}_{\text{reaction}} +\underbrace{\int a\,j\,\big(U(\theta^\mathrm{surf})-U(\bar\theta)\big)dx}_{\text{particle diffusion}},\]

with the overpotential \(\eta=\phi_s-\phi_e-U(\theta^\mathrm{surf})\). The identity follows from charge conservation, \(\partial i_e/\partial x=a\,j\) and \(i_s+i_e=I\), by integration by parts; on the finite-volume mesh the same summation by parts holds face by face.

Reference. Test protocol of the FreedomCAR Battery Test Manual for Power-Assist Hybrid Electric Vehicles (INL, 2003); model of Doyle, Fuller and Newman, J. Electrochem. Soc. 140 (1993) 1526; cell parameters of Chen et al., J. Electrochem. Soc. 167 (2020) 080534 (LG M50, 5 Ah). Check: the five loss parts add up to the terminal power loss at every output time, and their time integrals to the terminal energy loss of every pulse.

import numpy as np
from onesim.physics.chemistry import (
    BatteryElectrodeLayer,
    BatteryElectrolyteLayer,
    PorousElectrodeBattery,
)
from onesim.visualization import plots, theme
from scipy.integrate import solve_ivp

theme.set()

Cell at 80 % state of charge

faraday, area, soc0 = 96485.33212, 0.1027, 0.8
thermal = 8.314462618 * 298.15 / faraday
negative_ocp = lambda x, T: (
    1.9793 * np.exp(-39.3631 * x)
    + 0.2482
    - 0.0909 * np.tanh(29.8538 * (x - 0.1234))
    - 0.04478 * np.tanh(14.9159 * (x - 0.2769))
    - 0.0205 * np.tanh(30.4444 * (x - 0.6103))
)
positive_ocp = lambda y, T: (
    4.4875
    - 0.8090 * y
    - 0.0428 * np.tanh(18.5138 * (y - 0.5542))
    - 17.7326 * np.tanh(15.7890 * (y - 0.3117))
    + 17.5842 * np.tanh(15.9308 * (y - 0.3120))
)
negative = BatteryElectrodeLayer(
    thickness=85.2e-6,
    porosity=0.25,
    electrolyte_diffusivity=1.7694e-10 * 0.25**1.5,
    electrolyte_conductivity=0.9487 * 0.25**1.5,
    particle_radius=5.86e-6,
    particle_diffusivity=3.3e-14,
    active_fraction=0.75,
    maximum_concentration=33133,
    initial_stoichiometry=0.0279 + soc0 * (0.9014 - 0.0279),
    reference_exchange_current=6.48e-7 * np.sqrt(1000) * 33133 / 2,
    electronic_conductivity=215,
    open_circuit_potential=negative_ocp,
)
positive = BatteryElectrodeLayer(
    thickness=75.6e-6,
    porosity=0.335,
    electrolyte_diffusivity=1.7694e-10 * 0.335**1.5,
    electrolyte_conductivity=0.9487 * 0.335**1.5,
    particle_radius=5.22e-6,
    particle_diffusivity=4e-15,
    active_fraction=0.665,
    maximum_concentration=63104,
    initial_stoichiometry=0.9077 + soc0 * (0.2661 - 0.9077),
    reference_exchange_current=3.42e-6 * np.sqrt(1000) * 63104 / 2,
    electronic_conductivity=0.18,
    open_circuit_potential=positive_ocp,
)
separator = BatteryElectrolyteLayer(
    thickness=12e-6,
    porosity=0.47,
    electrolyte_diffusivity=1.7694e-10 * 0.47**1.5,
    electrolyte_conductivity=0.9487 * 0.47**1.5,
)
cell = PorousElectrodeBattery(
    negative=negative,
    separator=separator,
    positive=positive,
    electrolyte_concentration=1000,
    transference_number=0.2594,
)

HPPC test

Pulses of 1.5C (7.5 A) discharge and 1.125C charge at 80, 50 and 20 % state of charge; between the blocks the cell is discharged by 30 % at 1C and rests for 15 minutes.

The current switches abruptly. The stiff BDF integrator (the default of the model) gets a maximum step of 2 s through the time_solver port, so that no pulse can fall between two steps.

one_c, step = 5.0 / area, 0.3 * 5.0904 / 5.0 * 3600
starts = np.array([0.0, 100 + step + 900, 2 * (100 + step + 900)])
table = np.array(
    sorted(
        [
            (s + offset, rate)
            for s in starts
            for offset, rate in ((0, 1.5), (10, 0), (50, -1.125), (60, 0))
        ]
        + [
            (s + offset, rate)
            for s in starts[:2]
            for offset, rate in ((100, 1.0), (100 + step, 0))
        ]
    )
)
program = lambda t: one_c * table[np.searchsorted(table[:, 0], t, side="right") - 1, 1]
end = starts[2] + 100
times = np.unique(
    np.r_[
        np.linspace(0, end, 1500),
        np.concatenate([s + np.linspace(0, 100, 501) for s in starts]),
    ]
)
counts = (10, 5, 10)
stepping = lambda rhs, span, start, output_times, jacobian_sparsity: solve_ivp(
    rhs,
    span,
    start,
    method="BDF",
    t_eval=output_times,
    jac_sparsity=jacobian_sparsity,
    rtol=1e-8,
    atol=1e-9,
    max_step=2.0,
)
run = cell.solve(
    mode="DFN",
    current_density=program,
    final_time=end,
    radial_cells=16,
    through_cells=counts,
    output_times=times,
    time_solver=stepping,
)

Loss parts

All parts are evaluated on the finite-volume faces and cells of the solution, in W per m² of electrode.

nn, ns, nq = counts
current, ionic, phi_e, salt = (
    run.current_density,
    run.electrolyte_current_density,
    run.electrolyte_potential,
    run.electrolyte_concentration,
)
concentration_loss = -(
    ionic[:, 1:-1]
    * 2
    * (1 - cell.transference_number)
    * thermal
    * np.diff(np.log(salt), axis=1)
).sum(axis=1)
conduction_loss = (
    -(ionic[:, 1:-1] * np.diff(phi_e, axis=1)).sum(axis=1) - concentration_loss
)
electrode_loss = (
    -(
        (current[:, None] - ionic[:, 1:nn])
        * np.diff(run.solid_potential[:, :nn], axis=1)
    ).sum(axis=1)
    - (
        (current[:, None] - ionic[:, nn + ns + 1 : -1])
        * np.diff(run.solid_potential[:, nn:], axis=1)
    ).sum(axis=1)
    + current**2
    * (
        negative.thickness / nn / negative.electronic_conductivity
        + positive.thickness / nq / positive.electronic_conductivity
    )
    / 2
)
width = np.repeat([negative.thickness / nn, positive.thickness / nq], (nn, nq))
surface_area = np.repeat(
    [
        3 * negative.active_fraction / negative.particle_radius,
        3 * positive.active_fraction / positive.particle_radius,
    ],
    (nn, nq),
)
surface_potential = np.c_[
    negative_ocp(
        run.particle_surface_concentration[0] / negative.maximum_concentration, 0
    ),
    positive_ocp(
        run.particle_surface_concentration[1] / positive.maximum_concentration, 0
    ),
]
mean = [
    np.mean(c @ np.diff(np.linspace(0, 1, 17) ** 3), axis=1)
    / layer.maximum_concentration
    for c, layer in zip(run.particle_concentration, (negative, positive))
]
mean_potential = np.repeat(
    np.c_[negative_ocp(mean[0], 0), positive_ocp(mean[1], 0)], (nn, nq), axis=1
)
reaction = width * surface_area * run.interfacial_current_density
reaction_loss = (
    reaction
    * (
        run.solid_potential
        - np.c_[phi_e[:, :nn], phi_e[:, nn + ns :]]
        - surface_potential
    )
).sum(axis=1)
particle_loss = (reaction * (surface_potential - mean_potential)).sum(axis=1)
parts = {
    "electrolyte conduction": conduction_loss,
    "salt concentration": concentration_loss,
    "electrode conduction": electrode_loss,
    "reaction": reaction_loss,
    "particle diffusion": particle_loss,
}
terminal_loss = current * (
    positive_ocp(mean[1], 0) - negative_ocp(mean[0], 0) - run.terminal_voltage
)

Results

print(
    f"largest |terminal power loss - sum of the five parts| over the test: {np.abs(terminal_loss - sum(parts.values())).max():.1e} W/m² "
    f"(largest loss {terminal_loss.max():.1f} W/m²)"
)
pulses = {
    f"{label}\n{soc:.0%}": (s + offset, s + offset + 10)
    for s, soc in zip(starts, (0.8, 0.5, 0.2))
    for label, offset in (("discharge", 0.0), ("charge", 50.0))
}
energy = {
    name: {
        part: area
        * np.trapezoid(
            values[(times >= a) & (times <= b - 1e-9)],
            times[(times >= a) & (times <= b - 1e-9)],
        )
        for part, values in {**parts, "terminal": terminal_loss}.items()
    }
    for name, (a, b) in pulses.items()
}
print(
    "pulse                 terminal loss [J]   sum of parts [J]   "
    + "   ".join(f"{part:>11.11s}" for part in parts)
)
for name, e in energy.items():
    print(
        f"{name.replace('\n', ' at '):20s} {e['terminal']:15.4f} {sum(e[p] for p in parts):18.4f}   "
        + "   ".join(f"{100 * e[p] / e['terminal']:9.1f} %" for p in parts)
    )

Figure

block = (times >= starts[1] - 5) & (times <= starts[1] + 95)
fig = plots.figure(1, 3, size=(19, 5.4))
plots.line(
    times / 60,
    {"terminal voltage": run.terminal_voltage},
    right={"current [A]": area * current},
    xlabel="time [min]",
    ylabel="voltage [V]",
    right_label="current [A]",
    title="HPPC test at 80, 50 and 20 % SOC",
    legend="lower left",
    ax=fig[0],
)
plots.line(
    times[block] - starts[1],
    {part: area * values[block] for part, values in parts.items()},
    reference={
        "terminal power loss": (times[block] - starts[1], area * terminal_loss[block])
    },
    xlabel="time in the 50 % block [s]",
    ylabel="power loss [W]",
    title="Where the power goes",
    legend="upper right",
    ax=fig[1],
)
plots.bars(
    list(pulses),
    {part: [energy[name][part] for name in pulses] for part in parts},
    reference=[energy[name]["terminal"] for name in pulses],
    ylabel="energy loss in the 10 s pulse [J]",
    title="Loss parts per 10 s pulse",
    ax=fig[2],
)
plots.show()

Going further

The loss parts are the local heat sources of a thermal model: add them per layer to find where a cell heats up during fast charging, or repeat the test at lower temperature with smaller exchange currents and diffusivities.

Original OneSimulation Showcase entry