Application Library / Flow & Heat

HAMSTAD benchmark 2: moisture redistribution

A 200 mm hygroscopic wall in equilibrium with 95 % relative humidity dries towards 45 % and 65 % ambient air over 1000 hours.

To reproduce the case, put its notebook and accompanying inputs in the same folder. Use the Python environment set up in the installation tutorial. Start with the original parameters and compare the result with the check reported below.

Sorption isothermSurface vapour transferMesh studyAnalytical check

Run this example yourself. The OneSimulation Runtime brings the full Python library and an MCP server for Codex and Claude Code. It starts with a seven-day trial, then from €19 per month before any applicable tax.

Start the 7-day trial Compare the plans

HAMSTAD benchmark 2: moisture redistribution
HAMSTAD benchmark 2: moisture redistribution. Run the notebook to produce its own figures.

What it computes

OneSimulation solves the isothermal moisture balance with MoistureTransport: moisture content as conserved state, relative humidity from a Hansen sorption isotherm, liquid diffusivity and vapour permeability, VapourSurfaceTransfer at both surfaces; finite volumes with second-order BDF time stepping and Newton's method.

What it checks

On 200 cells with 1 h steps the moisture content profiles deviate from the analytical Fourier solution by at most 0.009, 0.003 and 0.0003 kg/m3 after 100, 300 and 1000 hours (1.4e-4 of the moisture drop), and the stored moisture matches the analytical value.

The notebook

The complete notebook, cell by cell. Run it to produce the figures and the comparison printout.

The moisture content \(w\) (kg/m³) of a porous material is in equilibrium with the relative humidity \(\varphi\) of its pore air through the sorption isotherm \(w(\varphi)\). Moisture moves as liquid (adsorbed films and capillary water) and as vapour,

\[\frac{\partial w}{\partial t}+\nabla\cdot\mathbf g=0,\qquad \mathbf g=-D_w\,\nabla w-\delta_p\,p_{sat}\,\nabla\varphi ,\]

with the moisture diffusivity \(D_w\) and the vapour permeability \(\delta_p\). At a surface the vapour exchange with the ambient air is \(\mathbf g\cdot\mathbf n=\beta\,p_{sat}\,(\varphi_s-\varphi_a)\). OneSimulation's MoistureTransport solves this balance with the moisture content as conserved state and the relative humidity from the isotherm; VapourSurfaceTransfer states the surface law.

QuantityValue
thickness200 mm
temperature20 °C, isothermal
sorption isotherm\(w=116\,\big(1-\ln\varphi/0.118\big)^{-0.869}\) kg/m³
moisture diffusivity \(D_w\)\(6\cdot10^{-10}\) m²/s
vapour permeability \(\delta_p\)\(10^{-15}\) s
initial state\(\varphi=95\,\%\)
ambient air\(\varphi_a=45\,\%\) at \(x=0\), \(65\,\%\) at \(x=0.2\) m
vapour transfer coefficient \(\beta\)\(10^{-3}\) s/m on both sides

Reference. C.-E. Hagentoft et al., Assessment method of numerical prediction models for combined heat, air and moisture transfer in building components: benchmarks for one-dimensional cases, J. Thermal Envelope and Building Science 27 (2004) 327-352. With the constant diffusivity the moisture content obeys the linear diffusion equation, the surface resistance is negligible (\(\beta\,p_{sat}\,L/(D_w\,dw/d\varphi)\sim10^5\)) and the vapour part is four to five orders smaller than the liquid part. The analytical solution is then the Fourier series of the slab between the surface equilibria \(w_0=w(0.45)\) and \(w_L=w(0.65)\), starting from \(w_i=w(0.95)\):

\[w(x,t)=w_0+(w_L-w_0)\frac{x}{L}+\sum_{n\ge1}b_n\sin\frac{n\pi x}{L}\,e^{-D_w(n\pi/L)^2t},\qquad b_n=\frac{2}{n\pi}\Big[(w_i-w_0)\big(1-(-1)^n\big)+(w_L-w_0)(-1)^n\Big].\]
import numpy as np
from onesim.cad.d1 import Line
from onesim.meshing import StructuredLineMesher
from onesim.numerics import Numerics
from onesim.numerics.fvm import CentralDifference, FiniteVolume, LeastSquaresGradient
from onesim.numerics.linear import SparseDirect
from onesim.numerics.nonlinear import Newton
from onesim.numerics.time import BDF
from onesim.physics.hydrodynamics import (
    HansenIsotherm,
    MoistureTransport,
    VapourSurfaceTransfer,
)
from onesim.simulation import Problem, Simulation
from onesim.simulation.initial_conditions import InitialValue
from onesim.visualization import plots, theme

theme.set()

Model

The isotherm of the benchmark is a Hansen isotherm \(w=w_h\,(1-\ln\varphi/a)^{-1/n}\) with \(w_h=116\) kg/m³, \(a=0.118\) and \(1/n=0.869\). The wall is a line through its thickness; the initial moisture content is the equilibrium with 95 %.

thickness, diffusivity, hour = 0.2, 6e-10, 3600.0
isotherm = HansenIsotherm(saturation_content=116.0, a=0.118, n=1 / 0.869)
wall = Line(start=(0.0, 0.0, 0.0), end=(thickness, 0.0, 0.0))
moisture = MoistureTransport(
    domain=wall.line,
    sorption_isotherm=isotherm,
    moisture_diffusivity=diffusivity,
    vapour_permeability=1e-15,
    temperature=293.15,
)
problem = Problem(
    name="HAMSTAD benchmark 2",
    geometry=wall,
    physics=(moisture,),
    initial_conditions=(
        InitialValue(moisture.moisture_content, float(isotherm.moisture_content(0.95))),
    ),
    boundary_conditions=(
        VapourSurfaceTransfer(
            physics=moisture,
            boundary=wall.boundaries.start,
            ambient_relative_humidity=0.45,
            transfer_coefficient=1e-3,
        ),
        VapourSurfaceTransfer(
            physics=moisture,
            boundary=wall.boundaries.end,
            ambient_relative_humidity=0.65,
            transfer_coefficient=1e-3,
        ),
    ),
)

Simulation

Finite volumes on 50 and 200 cells with the second-order BDF method, 4 h and 1 h steps over 1000 hours; Newton's method solves each step.

runs = {
    (cells, step): Simulation(
        problem=problem,
        mesh=StructuredLineMesher(cells=cells).generate(wall),
        numerics=Numerics(
            spatial=FiniteVolume(
                gradient=LeastSquaresGradient(), diffusion=CentralDifference()
            ),
            time_integrator=BDF(order=2),
            nonlinear_solver=Newton(
                linear_solver=SparseDirect(), absolute_tolerance=1e-9
            ),
        ),
    )
    .run(start_time=0.0, end_time=1000 * hour, time_step=step * hour)
    .field(moisture.moisture_content)
    for cells, step in ((50, 4.0), (200, 1.0))
}

Comparison with the analytical solution

The moisture content in every cell after 100, 300 and 1000 hours against the Fourier series.

w0, wl, wi = (float(isotherm.moisture_content(phi)) for phi in (0.45, 0.65, 0.95))
modes = np.arange(1, 4001)
wavenumbers = modes * np.pi / thickness
amplitudes = (
    2
    / (modes * np.pi)
    * ((wi - w0) * (1 - (-1.0) ** modes) + (wl - w0) * (-1.0) ** modes)
)
print(
    f"surface equilibria w(45 %) = {w0:.3f}, w(65 %) = {wl:.3f}, initial w(95 %) = {wi:.3f} kg/m³"
)
print(
    " cells   step [h]   time [h]   largest deviation [kg/m³]   relative to the drop w_i - w_0"
)
for (cells, step), field in runs.items():
    x = np.asarray(field.space.dof_coordinates)[:, 0]
    for hours in (100, 300, 1000):
        exact = (
            w0
            + (wl - w0) * x / thickness
            + np.sin(np.outer(x, wavenumbers))
            @ (amplitudes * np.exp(-diffusivity * wavenumbers**2 * hours * hour))
        )
        deviation = np.max(np.abs(np.asarray(field.at(hours * hour).values) - exact))
        print(
            f"{cells:6d} {step:9.0f} {hours:10d} {deviation:22.4f} {deviation / (wi - w0):27.1e}"
        )
fine = runs[(200, 1.0)]
times = np.arange(0, 1001, 20)
stored = np.array([fine.integrate(time=t * hour).value for t in times])
analytical_store = thickness * (
    (w0 + wl) / 2
    + np.exp(-diffusivity * np.outer(times * hour, wavenumbers**2))
    @ (amplitudes * (1 - (-1.0) ** modes) / (modes * np.pi))
)
print(
    f"stored moisture after 1000 h: {stored[-1]:.4f} kg/m², analytical {analytical_store[-1]:.4f} kg/m², "
    f"largest deviation over the run {np.max(np.abs(stored - analytical_store)):.4f} kg/m²"
)

Figure

Left: the moisture content profiles on 200 cells (markers, every fourth cell) and the analytical solution (dashed). Middle: the relative humidity in the pores from the isotherm, which carries the strong nonlinearity of the problem. Right: the moisture stored in the wall over time.

x = np.asarray(fine.space.dof_coordinates)[:, 0]
profiles = {
    f"{hours} h": np.asarray(fine.at(hours * hour).values) for hours in (100, 300, 1000)
}
fig = plots.figure(1, 3, size=(18, 5))
plots.line(
    points={label: (1e3 * x[::4], values[::4]) for label, values in profiles.items()},
    reference={
        f"{hours} h": (
            1e3 * x,
            w0
            + (wl - w0) * x / thickness
            + np.sin(np.outer(x, wavenumbers))
            @ (amplitudes * np.exp(-diffusivity * wavenumbers**2 * hours * hour)),
        )
        for hours in (100, 300, 1000)
    },
    hlines={"initial": wi},
    xlabel="position x [mm]",
    ylabel="moisture content w [kg/m³]",
    title="Moisture content (dashed: analytical)",
    legend="lower center",
    ax=fig[0],
)
plots.line(
    y={
        label: (1e3 * x, 100 * isotherm.relative_humidity(values))
        for label, values in profiles.items()
    },
    xlabel="position x [mm]",
    ylabel="relative humidity [%]",
    title="Relative humidity in the pores",
    legend="lower center",
    ax=fig[1],
)
plots.line(
    y={"OneSimulation": (times, stored)},
    reference={"analytical": (times, analytical_store)},
    xlabel="time [h]",
    ylabel="stored moisture [kg/m²]",
    title="Moisture in the wall",
    legend="upper right",
    ax=fig[2],
)
plots.show()

Going further

Give the material a humidity-dependent diffusivity, moisture_diffusivity= any function of the relative humidity, or a SorptionIsotherm from measured data: the model stays the same and only the analytical comparison is lost. The same declaration runs on planar and revolved sections and in three dimensions, for example a corner of the wall or a drying timber column, and FixedRelativeHumidity and MoistureFlux state other surface conditions.

Original OneSimulation Showcase entry