What it computes
OneSimulation evaluates a signal-flow graph of setpoint, error, proportional controller, gain and first-order plant in time.
What it checks
The output matches y_inf (1 - e^{-t/tau_cl}) with y_inf = K Kp r/(1+K Kp) and tau_cl = tau/(1+K Kp) to about 1e-12.
The notebook
The complete notebook, cell by cell. Run it to produce the figures and the comparison printout.
A first-order plant with the time constant \(\tau\) and the static gain \(K\),
is driven by a proportional controller \(u=K_p\,(r-y)\) that compares the output \(y\) with a constant setpoint \(r\). OneSimulation builds the loop from signal blocks (setpoint, summing junction, controller, plant) and integrates the single continuous state with the classical fourth-order Runge-Kutta method.
Reference. Substituting the control law gives another first-order system, so the closed-loop step response from rest is
A proportional controller speeds the plant up by the factor \(1+KK_p\) but leaves the steady-state offset \(r-y_\infty=r/(1+KK_p)\). Both facts are checked below.
import numpy as np
from onesim.physics.systems import ControlSignalFlowProvider, SignalBlock
from onesim.visualization import plots, theme
theme.set()Parameters and model
The parameters can be changed; the reference stays valid for any positive gains and time constant. The values describe a sluggish process (20 s time constant, gain 2) under a moderate proportional gain, so the offset remains clearly visible.
time_constant = 20.0
plant_gain = 2.0
proportional_gain = 4.0
setpoint = 1.0
loop_gain = plant_gain * proportional_gain
steady_output = loop_gain / (1.0 + loop_gain) * setpoint
closed_loop_time_constant = time_constant / (1.0 + loop_gain)
end_time = 6.0 * closed_loop_time_constant
time_step = 0.01
print(
f"loop gain K*Kp = {loop_gain:.1f}, closed-loop time constant = {closed_loop_time_constant:.3f} s "
f"(open loop {time_constant:.1f} s), steady output = {steady_output:.4f}"
)
loop = ControlSignalFlowProvider(
blocks=(
SignalBlock("setpoint", "constant", parameters={"value": setpoint}),
SignalBlock(
"error",
"sum",
inputs=("setpoint", "plant"),
parameters={"weights": (1.0, -1.0)},
),
SignalBlock(
"controller",
"pid",
inputs=("error",),
parameters={"proportional_gain": proportional_gain},
),
SignalBlock(
"actuator", "gain", inputs=("controller",), parameters={"gain": plant_gain}
),
SignalBlock(
"plant",
"first_order",
inputs=("actuator",),
parameters={"time_constant": time_constant, "initial_value": 0.0},
),
),
final_time=end_time,
time_step=time_step,
time_integration="classical_rk4",
)
run = loop.execute()
times = np.asarray(run.times)
outputs = np.asarray(run.signals["plant"])
commands = np.asarray(run.signals["controller"])
print("evaluation order:", " -> ".join(run.evaluation_order))Comparison with the closed-form solution
The closed-loop exponential is evaluated at every stored time, the closed-loop time constant is fitted to the simulated approach, and the control law is verified sample by sample. A passing check shows that this numerical example agrees with the linear loop equations; it is not a measurement of a real process.
reference = steady_output * (1.0 - np.exp(-times / closed_loop_time_constant))
max_output_error = float(np.max(np.abs(outputs - reference)))
print(
f"Maximum output error against the closed-loop exponential: {max_output_error:.3e}"
)
approach = steady_output - outputs
fitted_rate = -np.polyfit(times, np.log(approach), 1)[0]
fitted_time_constant = 1.0 / fitted_rate
print(
f"Closed-loop time constant: fitted {fitted_time_constant:.5f} s, exact {closed_loop_time_constant:.5f} s"
)
final_offset = setpoint - outputs[-1]
expected_offset = setpoint / (1.0 + loop_gain)
print(
f"Steady-state offset: simulated {final_offset:.5f}, exact r/(1+K Kp) = {expected_offset:.5f}"
)Figure
dense_t = np.linspace(0.0, end_time, 400)
fig = plots.figure(2, 1, size=(8, 7))
plots.line(
times,
points={"OneSimulation RK4": (times[::10], outputs[::10])},
reference={
"exact step response": (
dense_t,
steady_output * (1.0 - np.exp(-dense_t / closed_loop_time_constant)),
)
},
hlines={"setpoint r": setpoint, "steady state K Kp r / (1 + K Kp)": steady_output},
vlines={"closed-loop time constant": closed_loop_time_constant},
ylabel="plant output y",
title="First-order plant under proportional control",
legend="lower right",
ax=fig[0],
)
plots.line(
times,
{"controller output u = Kp (r - y)": commands},
hlines={"steady state Kp r / (1 + K Kp)": proportional_gain * expected_offset},
xlabel="time [s]",
ylabel="control signal u",
ax=fig[1],
)
plots.show()Going further
Raise proportional_gain and the offset shrinks as \(1/(1+KK_p)\) while the loop becomes faster; it can never vanish with proportional action alone. Add an integral_gain to the controller block and the offset disappears, but the loop becomes second order and may overshoot; derive the new characteristic equation \(\tau s^2+(1+KK_p)s+KK_i=0\) before adapting the checks. A saturation block between controller and actuator or a transport_delay in the feedback path turns the example into the standard anti-windup and dead-time studies.