Application Library / Chemistry

Neutralisation of chlorine in a scrubber

Dissolved chlorine destroyed by the hydroxide of an alkaline scrubber liquid within microseconds.

To reproduce the case, put its notebook and accompanying inputs in the same folder. Use the Python environment set up in the installation tutorial. Start with the original parameters and compare the result with the check reported below.

Second-order kineticsMicrosecond time scaleReaction ordersClosed-form check

Run this example yourself. The OneSimulation Runtime brings the full Python library and an MCP server for Codex and Claude Code. It starts with a seven-day trial, then from €19 per month before any applicable tax.

Start the 7-day trial Compare the plans

Neutralisation of chlorine in a scrubber
Neutralisation of chlorine in a scrubber. Run the notebook to produce its own figures.

What it computes

OneSimulation integrates Cl2 + 2 OH- -> Cl- + OCl- with a rate of first order in each reactant, declared separately from the stoichiometry, for four hydroxide excesses with the classical Runge-Kutta method.

What it checks

All chlorine histories match the closed-form solution for unequal reactant ratios to 4e-9 of the initial chlorine or better, the times to 99 % removal agree with the closed form (60.71 against 60.70 us down to 0.47 us), and the hydroxide left matches the stoichiometry.

The notebook

The complete notebook, cell by cell. Run it to produce the figures and the comparison printout.

Chlorine is removed from waste gas by absorption in caustic soda. In the liquid the dissolved chlorine is destroyed by hydroxide,

\[\mathrm{Cl_2 + 2\,OH^- \longrightarrow Cl^- + OCl^- + H_2O},\qquad r = k\,c_\mathrm{Cl_2}\,c_\mathrm{OH^-},\]

a reaction of first order in each reactant although two hydroxide ions are consumed. The liquid volume is taken as perfectly mixed and constant (0D), and the chlorine is assumed to have dissolved almost to saturation, \(c_\mathrm{Cl_2,0}=10^{-2}\) mol/m³, before it reacts. The rate constant is of the order of the diffusion limit, \(k=10^7\) m³/(mol s), so the liquid must be followed on a microsecond scale.

speciesstart [mol/m³]role
Cl₂0.01dissolved chlorine
OH⁻0.025 ... 1hydroxide of the washing liquid
Cl⁻, OCl⁻0products

Reference. With the extent \(x\), \(c_\mathrm{Cl_2}=A_0-x\) and \(c_\mathrm{OH^-}=B_0-2x\); separating \(\dot x = k(A_0-x)(B_0-2x)\) gives the closed form (Levenspiel, Chemical Reaction Engineering, chapter 3, irreversible second-order reactions with unequal reactant ratio)

\[x(t)=\frac{B_0\,(1-E)}{2-(B_0/A_0)\,E},\qquad E=e^{(B_0-2A_0)\,k\,t} .\]

For a large hydroxide excess this reduces to the pseudo-first-order decay \(A_0e^{-kB_0t}\).

import numpy as np
from onesim.cad.geometry import LumpedDomain
from onesim.meshing import LumpedMesh
from onesim.numerics import Numerics
from onesim.numerics.discretization import LumpedParameters
from onesim.numerics.time import ClassicalRungeKutta4
from onesim.physics.chemistry import (
    ReactionIR,
    ReactionKinetics,
    ReactionNetworkIR,
    SpeciesIR,
)
from onesim.simulation import Problem, Simulation
from onesim.simulation.initial_conditions import InitialValue
from onesim.visualization import plots, theme

theme.set()

Model

The reaction order in hydroxide is declared separately from its stoichiometric coefficient. Water is the solvent and is not tracked, so the element balance is switched off.

k = 1e7
network = ReactionNetworkIR(
    "chlorine_neutralisation",
    "1",
    species=(
        SpeciesIR("Cl2", 0, 1.18e-25),
        SpeciesIR("OH", -1, 2.82e-26),
        SpeciesIR("Cl", -1, 5.89e-26),
        SpeciesIR("OCl", -1, 8.55e-26),
    ),
    reactions=(
        ReactionIR(
            "neutralisation",
            {"Cl2": 1, "OH": 2},
            {"Cl": 1, "OCl": 1},
            {"kind": "constant", "value": k},
            forward_orders={"OH": 1},
        ),
    ),
    strict_balance=False,
)

Runs

Four washing liquids, from a slight hydroxide excess over the stoichiometric 0.02 mol/m³ to a strong caustic of 1 mol/m³. Each run lasts until 99.9 % of the chlorine is gone, with 800 Runge-Kutta steps.

domain = LumpedDomain()
chlorine = 0.01
hydroxide = (0.025, 0.05, 0.2, 1.0)
models = {
    B0: ReactionKinetics(domain=domain.system, network=network) for B0 in hydroxide
}
end = {
    B0: np.log((B0 - 1.998 * chlorine) / (0.001 * B0)) / ((B0 - 2 * chlorine) * k)
    for B0 in hydroxide
}
runs = {
    B0: Simulation(
        problem=Problem(
            name=f"scrubber with {B0} mol/m3 OH",
            geometry=domain,
            physics=(model,),
            initial_conditions=(
                InitialValue(model.concentration("Cl2"), chlorine),
                InitialValue(model.concentration("OH"), B0),
                InitialValue(model.concentration("Cl"), 0.0),
                InitialValue(model.concentration("OCl"), 0.0),
            ),
        ),
        mesh=LumpedMesh(domain),
        numerics=Numerics(
            spatial=LumpedParameters(), time_integrator=ClassicalRungeKutta4()
        ),
    ).run(start_time=0.0, end_time=end[B0], time_step=end[B0] / 800)
    for B0, model in models.items()
}

Comparison with the closed form

The chlorine history of every run against \(A_0-x(t)\), and the hydroxide left at the end against the stoichiometry.

extent = (
    lambda B0, t: B0
    * (1 - np.exp((B0 - 2 * chlorine) * k * t))
    / (2 - B0 / chlorine * np.exp((B0 - 2 * chlorine) * k * t))
)
histories = {
    B0: run.field(models[B0].concentration("Cl2")).time_series()
    for B0, run in runs.items()
}
for B0, (t, c) in histories.items():
    hydroxide_left = runs[B0].field(models[B0].concentration("OH")).values[0]
    print(
        f"OH0 = {B0:5.3f} mol/m^3: largest deviation from the closed form {np.max(np.abs(c - (chlorine - extent(B0, t)))) / chlorine:.1e} of Cl2_0; "
        f"time to 99 % removal {t[np.argmax(c < 0.01 * chlorine)] * 1e6:6.2f} us (closed form "
        f"{np.log((B0 - 1.98 * chlorine) / (0.01 * B0)) / ((B0 - 2 * chlorine) * k) * 1e6:6.2f} us); OH left {hydroxide_left:.5f} (stoichiometry {B0 - 2 * chlorine * (1 - c[-1] / chlorine):.5f})"
    )
t_ex, c_ex = histories[1.0]
print(
    f"strong caustic: largest deviation from the pseudo-first-order decay {np.max(np.abs(c_ex - chlorine * np.exp(-k * 1.0 * t_ex))) / chlorine:.1e} of Cl2_0"
)

Figure

Dissolved chlorine over time for the four washing liquids against the closed form, and the hydroxide consumed together with the products formed in the liquid with the smallest excess.

t_fine = {B0: np.geomspace(end[B0] / 1000, end[B0], 400) for B0 in hydroxide}
t25 = runs[0.025].field(models[0.025].concentration("OH")).times
fig = plots.figure(1, 2, size=(14, 5))
plots.line(
    points={
        f"OH0 = {B0} mol/m3": (t[10::20] * 1e6, c[10::20] / chlorine)
        for B0, (t, c) in histories.items()
    },
    reference={
        f"OH0 = {B0} mol/m3": (t_fine[B0] * 1e6, 1 - extent(B0, t_fine[B0]) / chlorine)
        for B0 in hydroxide
    },
    scale="loglog",
    ylimits=(1e-3, 1.5),
    xlabel="time [us]",
    ylabel="Cl2 / Cl2 at start",
    title="Dissolved chlorine, dashed: closed form",
    legend="lower left",
    ax=fig[0],
)
plots.line(
    y={
        name: (
            np.asarray(t25) * 1e6,
            runs[0.025].field(models[0.025].concentration(name)).time_series()[1],
        )
        for name in ("Cl2", "OH", "Cl", "OCl")
    },
    xlabel="time [us]",
    ylabel="concentration [mol/m3]",
    title="Liquid with OH0 = 0.025 mol/m3",
    legend="center right",
    ax=fig[1],
)
plots.show()

Going further

Couple the liquid to a gas phase with a mass-transfer coefficient to see when absorption, not reaction, limits the scrubber; at these rate constants the reaction happens inside the liquid film, which is the regime of the enhancement factor. Lower the hydroxide below the stoichiometric amount to see the chlorine break through.

Original OneSimulation Showcase entry