Application Library / Biophysics

Steady cable equation

Electrotonic voltage decay along a passive nerve cable, graded against cable theory.

To reproduce the case, put its notebook and accompanying inputs in the same folder. Use the Python environment set up in the installation tutorial. Start with the original parameters and compare the result with the check reported below.

Steady stateCable modelClosed-form check

Run this example yourself. The OneSimulation Runtime brings the full Python library and an MCP server for Codex and Claude Code. It starts with a seven-day trial, then from €19 per month before any applicable tax.

Start the 7-day trial Compare the plans

Steady cable equation
Steady cable equation. Run the notebook to produce its own figures.

What it computes

OneSimulation evolves the passive cable (monodomain) model to steady state on a 1D line with a voltage clamp at one end and a sealed far end.

What it checks

The profile matches the sealed-end decay V(x)=V0 cosh((L-x)/lambda)/cosh(L/lambda); the fitted space constant is within about 1.6 %.

The notebook

The complete notebook, cell by cell. Run it to produce the figures and the comparison printout.

A long, thin passive nerve fibre (a "cable") is held at a fixed membrane potential \(V_0\) at one end (\(x=0\)). The other end is sealed (no current leaves it). Away from the clamped end the potential decays smoothly because current leaks steadily across the membrane while it spreads along the fibre.

The passive membrane is modelled as a monodomain cable with a single linear leak channel of conductance \(g_L\) and reversal potential \(E_L\):

\[C_m\,\frac{\partial V}{\partial t} = \frac{\sigma}{\beta}\,\frac{\partial^2 V}{\partial x^2} - g_L\,(V-E_L),\]

with axial conductivity \(\sigma\), surface-to-volume ratio \(\beta\) and membrane capacitance \(C_m\). OneSimulation integrates this in time on a real 1D line mesh until the transient has died out and only the steady profile remains.

Reference. In steady state (\(\partial_t V=0\)) the deviation \(v=V-E_L\) obeys \(\lambda^2 v''-v=0\) with the space constant

\[\lambda=\sqrt{\dfrac{\sigma}{\beta\,g_L}}\;=\;\sqrt{\dfrac{r_m}{r_i}}.\]

For a clamp \(v(0)=v_0\) at \(x=0\) and a sealed end \(v'(L)=0\) at \(x=L\) the closed-form solution is the hyperbolic-cosine profile

\[v(x)=v_0\,\frac{\cosh\!\big((L-x)/\lambda\big)}{\cosh(L/\lambda)}.\]

We check the computed steady profile against this form and also recover the space constant \(\lambda\) from a fit of the numerical solution.

import numpy as np
from onesim.cad.d1 import Line
from onesim.meshing import StructuredLineMesher
from onesim.physics.biophysics import (
    MembraneChannel,
    MembraneCurrentElectrode,
    MembraneKinetics,
    MembraneVoltageClamp,
    Monodomain,
)
from onesim.visualization import plots, theme

theme.set()

Parameters

The values are freely adjustable and in SI units. They are chosen so that the cable is several space constants long, which makes the electrotonic decay clearly visible while the sealed end still has a small, non-zero potential.

L = 0.06
cells = 240
sigma = 1.0
beta = 2000.0
C_m = 0.01
g_L = 2.0
E_L = -0.065
delta = 0.025
V0 = E_L + delta

lam = np.sqrt(sigma / (beta * g_L))
print(f"space constant lambda = {lam*1000:.3f} mm,  L/lambda = {L/lam:.2f}")

Characteristic times: membrane charging C_m/g_L and axial spreading L^2 * beta * C_m / sigma. The run must be long enough for both to settle.

D = sigma / (beta * C_m)
tau = max(C_m / g_L, L * L / D)
end_time = 25.0 * tau
print(
    f"diffusivity = {D:.3e} m^2/s,  settling time ~ {tau:.3f} s,  end time = {end_time:.3f} s"
)

line = Line(start=(0.0, 0.0, 0.0), end=(L, 0.0, 0.0))
mesh = StructuredLineMesher(cells=cells).generate(line)

model = Monodomain(
    conductivity=sigma,
    capacitance=C_m,
    surface_to_volume=beta,
    membrane=MembraneKinetics(
        channels=(
            MembraneChannel(name="leak", conductance=g_L, reversal_potential=E_L),
        ),
    ),
)

Both ends carry an explicit boundary condition: a voltage clamp at x = 0 and a sealed (zero-current) electrode at x = L.

electrodes = (
    MembraneVoltageClamp(boundary=line.boundaries.start, voltage=lambda t: V0),
    MembraneCurrentElectrode(boundary=line.boundaries.end, current_density=0.0),
)

times = np.linspace(0.0, end_time, 60)
result = model.solve(
    mesh=mesh,
    times=times,
    max_step=tau / 50.0,
    initial_voltage=E_L,
    electrodes=electrodes,
)
print("Mesh nodes:", result.voltage.shape[1], " stored times:", len(result.times))

Comparison with the closed-form steady profile

The last stored time is deep in the steady regime. We compare the computed deviation from rest with the hyperbolic-cosine reference and also fit the space constant.

x = result.coordinates[:, 0]
order = np.argsort(x)
x = x[order]
v_num = result.voltage[-1][order] - E_L


def reference(xx):
    return delta * np.cosh((L - xx) / lam) / np.cosh(L / lam)


v_ref = reference(x)
max_abs_error = float(np.max(np.abs(v_num - v_ref)))
rel_error = max_abs_error / delta
print(
    f"maximum deviation from the cosh reference: {max_abs_error*1000:.4f} mV  ({100*rel_error:.2f} % of the clamp step)"
)

drift = float(np.max(np.abs(result.voltage[-1] - result.voltage[-2])))
print(f"change over the last stored interval: {drift*1e6:.3f} uV")

Recover the space constant from the numerical profile. Over the interior, away from the sealed end, the decay is essentially a pure exponential e^{-x/lambda}.

interior = x < 0.6 * L
slope = np.polyfit(x[interior], np.log(v_num[interior]), 1)[0]
lam_fit = -1.0 / slope
print(f"fitted space constant: {lam_fit*1000:.3f} mm  (reference {lam*1000:.3f} mm)")

Figure

xs = np.linspace(0.0, L, 400)
plots.line(
    points={"OneSimulation": (x * 1000, v_num * 1000)},
    reference={"cable equation (cosh)": (xs * 1000, reference(xs) * 1000)},
    vlines={f"length constant = {lam * 1000:.2f} mm": lam * 1000},
    xlabel="position x [mm]",
    ylabel="depolarisation V - E_L [mV]",
    title="Steady passive cable",
)
plots.show()

Going further

Lengthen the cable and the sealed-end potential drops toward zero, recovering the semi-infinite result \(v(x)=v_0 e^{-x/\lambda}\). Raise the leak conductance \(g_L\) (a leakier membrane) and the space constant \(\lambda\) shrinks, so the signal decays over a shorter distance.

Original OneSimulation Showcase entry