To reproduce the case, put its notebook and accompanying inputs in the same folder. Use the Python environment set up in the installation tutorial. Start with the original parameters and compare the result with the check reported below.
Run this example yourself. The OneSimulation Runtime brings the full Python library and an MCP server for Codex and Claude Code. It starts with a seven-day trial, then from €19 per month before any applicable tax.

What it computes
OneSimulation evolves a one-dimensional elastic vessel with a tube wall law and a Windkessel termination and tracks the propagating pulse.
What it checks
The pulse speed matches c0 = sqrt(beta/(2 rho)) (Moens-Korteweg) within about 0.03 %, and the characteristic impedance rho c0/A0 within about 0.04 %.
The notebook
The complete notebook, cell by cell. Run it to produce the figures and the comparison printout.
Blood vessels are compliant tubes: a local rise in pressure widens the vessel, and the interplay between the inertia of the blood and the elasticity of the wall lets a pressure pulse run along the artery much faster than the blood itself moves. For a thin-walled elastic tube of resting radius \(r_0\), wall thickness \(h\), Young's modulus \(E\) and Poisson ratio \(\nu\) the small-amplitude pulse-wave speed is the Moens-Korteweg speed
We launch a small, smooth area pulse in a straight vessel, let it split into a forward- and a backward-running pulse, and measure how fast they travel.
OneSimulation integrates the one-dimensional cross-section-averaged blood-flow equations for the lumen area \(A(x,t)\) and the volume flow \(Q(x,t)\),
closed by the elastic tube law of ArterialSegment,
with a second-order finite-volume scheme (minmod reconstruction, Rusanov flux) and characteristic-based junction and terminal conditions.
Reference. Linearising the system about the resting area \(A_0\) gives the wave speed \(c^2 = (A/\rho)\,\mathrm{d}p/\mathrm{d}A\). For the tube law above \(\mathrm{d}p/\mathrm{d}A = \beta/(2\sqrt{A A_0})\), so at \(A=A_0\)
Matching the tube law to a thin elastic wall gives \(\beta=\sqrt{\pi}\,E h/\big((1-\nu^2)\sqrt{A_0}\big)\), and with \(A_0=\pi r_0^2\) this \(c_0\) is exactly the Moens-Korteweg speed. A linear forward-running pulse also fixes the ratio of its pressure and flow perturbations, the characteristic impedance \(Z_0=\rho c_0/A_0\); we check both.
import numpy as np
from onesim.physics.biophysics import (
ArterialNetwork,
ArterialPressure,
ArterialSegment,
WindkesselTerminal,
)
from onesim.visualization import plots, theme
theme.set()Parameters
The vessel is of aortic size with a wall of moderate stiffness, filled with blood. The initial disturbance is a narrow Gaussian area bump of one part in a thousand of the resting area, so the wave stays linear. The run ends before the two pulses reach the ends of the vessel, so the terminals do not influence the speed measurement.
rho = 1060.0
r0 = 0.010
h = 1.5e-3
E = 4.0e5
nu = 0.5
L = 1.0
x0 = 0.5 * L
sigma = 0.03
amplitude = 1.0e-3
cells = 400
final_time = 0.05
A0 = np.pi * r0**2
beta = np.sqrt(np.pi) * E * h / ((1.0 - nu**2) * np.sqrt(A0))
c_formula = np.sqrt(E * h / (2.0 * rho * (1.0 - nu**2) * r0))
c_tube_law = np.sqrt(beta / (2.0 * rho))
Z0 = rho * c_formula / A0
print(f"A0 = {A0*1e4:.3f} cm^2, beta = {beta:.0f} Pa")
print(
f"Moens-Korteweg speed c0 = {c_formula:.4f} m/s, tube-law speed sqrt(beta/2rho) = {c_tube_law:.4f} m/s,"
f" c0*t = {c_formula*final_time:.3f} m"
)
def initial_area(x):
return A0 * (1.0 + amplitude * np.exp(-((x - x0) ** 2) / (2.0 * sigma**2)))
vessel = ArterialSegment(
name="aorta",
start="inlet",
end="outlet",
length=L,
cells=cells,
reference_area=A0,
wall_stiffness=beta,
)
network = ArterialNetwork(
segments=(vessel,),
density=rho,
terminals=(
ArterialPressure(node="inlet", pressure=0.0),
WindkesselTerminal(
node="outlet",
proximal_resistance=Z0,
distal_resistance=5.0 * Z0,
compliance=1.0e-9,
reference_pressure=0.0,
initial_pressure=0.0,
),
),
)
result = network.solve(
times=np.linspace(0.0, final_time, 6),
max_step=1.0e-3,
initial_area={"aorta": initial_area},
initial_flow={"aorta": lambda x: np.zeros_like(x)},
)
print(
f"Integrated to t = {result.times[-1]:.4f} s with {len(result.stage_times)} explicit stages"
)Measure the pulse speed and the characteristic impedance
The relative area perturbation \(\delta A/A_0\) at the final time consists of two pulses that keep their shape. The centroid of \(|\delta A|\) on each half of the vessel marks the pulse position; the travelled distance divided by the elapsed time is the measured speed. On the forward pulse the flow and pressure perturbations are tied by \(\delta p = Z_0\,Q\) (and \(\delta p=-Z_0 Q\) on the backward pulse), which gives an independent check of the wall law.
x = result.coordinates["aorta"]
area_final = result.area["aorta"][-1]
flow_final = result.flow["aorta"][-1]
pressure_final = result.pressure["aorta"][-1]
t_end = float(result.times[-1])
delta_a = area_final / A0 - 1.0
weight = np.abs(delta_a)
right = x > x0
left = x < x0
centroid_right = np.sum(x[right] * weight[right]) / np.sum(weight[right])
centroid_left = np.sum(x[left] * weight[left]) / np.sum(weight[left])
speed_right = (centroid_right - x0) / t_end
speed_left = (x0 - centroid_left) / t_end
speed_measured = 0.5 * (speed_right + speed_left)
rel_error = abs(speed_measured - c_formula) / c_formula
print(f"forward pulse speed = {speed_right:.4f} m/s")
print(f"backward pulse speed = {speed_left:.4f} m/s")
print(f"measured pulse speed = {speed_measured:.4f} m/s")
print(f"relative error vs Moens-Korteweg = {100*rel_error:.2f} %")
peak_right = np.argmax(np.where(right, delta_a, -np.inf))
peak_left = np.argmax(np.where(left, delta_a, -np.inf))
Z_right = pressure_final[peak_right] / flow_final[peak_right]
Z_left = -pressure_final[peak_left] / flow_final[peak_left]
Z_measured = 0.5 * (Z_right + Z_left)
Z_error = abs(Z_measured - Z0) / Z0
print(
f"peak pressure of the forward pulse = {pressure_final[peak_right]:.2f} Pa,"
f" peak flow = {flow_final[peak_right]*1e6:.3f} ml/s"
)
print(
f"characteristic impedance: measured {Z_measured:.4e}, rho*c0/A0 = {Z0:.4e} Pa·s/m^3"
f" (relative error {100*Z_error:.2f} %)"
)Figure
predicted = [x0 - c_formula * t_end, x0 + c_formula * t_end]
fig = plots.figure(1, 2, size=(12, 4.8))
plots.line(
x,
{
f"computed, t = {t_end * 1e3:.0f} ms": delta_a * 1e3,
"initial area bump": (result.area["aorta"][0] / A0 - 1.0) * 1e3,
},
points={"predicted x0 ± c0 t": (predicted, np.interp(predicted, x, delta_a * 1e3))},
vlines={"measured pulse centroids": centroid_left, "": centroid_right},
xlabel="position along the vessel x [m]",
ylabel="area perturbation dA/A0 [‰]",
title=f"Pulse speed: measured {speed_measured:.3f} m/s, Moens-Korteweg {c_formula:.3f} m/s",
ax=fig[0],
)
plots.line(
x,
{"pressure perturbation": pressure_final},
reference={"Z0 Q with Z0 = rho c0 / A0": Z0 * flow_final},
xlabel="position along the vessel x [m]",
ylabel="pressure [Pa]",
title="Forward pulse: p = +Z0 Q, backward pulse: p = -Z0 Q",
ax=fig[1],
)
plots.show()Going further
Stiffen the wall (E) or thin the lumen (r0) and watch the pulse run faster as \(\sqrt{E h/r_0}\): arterial stiffening with age shows up directly as a higher pulse-wave velocity. Lengthen final_time so the forward pulse reaches the outlet: with the proximal resistance matched to \(Z_0\) it is absorbed almost without reflection, while a sealed outlet (ArterialInflow(flow=0)) sends it back doubled in pressure. Raise amplitude towards unity and the crest, which travels faster than the trough, steepens into a shock-like front.