"""OneSimulation example: dielectric shielding by a thin high-permittivity shell in a capacitor.
Requires the installed, activated OneSimulation runtime.

A tube with a thin wall of high permittivity sits in the field between two capacitor plates and
draws the electric flux into its wall, which lowers the field inside. The wall is once resolved by
the mesh and once replaced by a thin dielectric layer on its mid-line. Both are compared for four
wall thicknesses, together with the exact solution for a coated cylinder and the capacitance.
"""

# # Dielectric shielding by a thin high-permittivity shell
#
# A thin layer of a material with high permittivity — a ceramic coating, a water film, a filled
# polymer — guides the electric flux along itself and screens what lies behind it. A **thin
# dielectric layer** replaces the layer by a face: the displacement flux along it is carried with
# $\varepsilon_2 d$,
#
# $$\nabla_t\cdot\big(\varepsilon_2\,d\,\nabla_t V\big)=-\big[\!\big[D_n\big]\!\big],$$
#
# and the potential may jump across it with the normal capacitance per area $\varepsilon_2/d$, so a
# layer of high or of low permittivity is covered by the same condition.
#
# Two parallel plates 80 mm apart, 80 mm wide, hold a voltage of 1 V across air. In the middle sits
# a tube of outer radius $b=5$ mm with a wall of thickness $d$ and relative permittivity
# $\varepsilon_r=20$; inside the tube is air. The electrostatic potential solves
#
# $$\nabla\cdot(\varepsilon\,\nabla V)=0 .$$
#
# | edge | condition |
# |---|---|
# | `terminal`, upper plate | $V=1$ V |
# | `ground`, lower plate | $V=0$ |
# | `insulated`, left and right | $D_n=0$ |
#
# Far from the tube the field is $E_0=12.5$ V/m. Two models are solved for walls of
# $d=0.1,\;0.25,\;0.5,\;1$ mm: the **resolved model** meshes the wall as its own region, the **thin
# model** puts the dielectric layer on the circle $r=b-d/2$ in the middle of the wall. The thin
# model is a first-order approximation in $d/b$: it keeps the air in the place of the wall and
# carries the flux along the layer on the mid-line, so its error grows in proportion to the
# thickness of the wall.
#
# The space between the plates and the tube come from the CAD files
# `dielectric_shell_field_shielding*.step`; the script `dielectric_shell_field_shielding_geometry.py`
# builds them with the CAD objects of OneSimulation. The two-dimensional model is their mid-plane
# section.
#
# **Reference.** A coated cylinder in a uniform field of an unbounded medium has a uniform field
# inside (Jackson, *Classical Electrodynamics*, 3rd ed., problem 4.10). With core and surroundings of
# $\varepsilon_0$ and a shell of $\varepsilon_r\varepsilon_0$ between $a=b-d$ and $b$,
#
# $$\frac{E_\text{in}}{E_0}=\frac{4\,\varepsilon_r}{(1+\varepsilon_r)^2-(\varepsilon_r-1)^2\,a^2/b^2}.$$
#
# The plates are 16 tube radii apart, so they change the field inside the tube by about a percent.

import numpy as np
from onesim.cad.exchange import load
from onesim.materials import regionwise
from onesim.meshing import TriangularMesher, interface
from onesim.numerics import Numerics
from onesim.numerics.fem import FiniteElement, Lagrange
from onesim.numerics.linear import SparseDirect
from onesim.physics.electrostatics import (
    FixedPotential,
    PoissonEquation,
    ThinDielectricLayer,
    ZeroNormalElectricDisplacement,
)
from onesim.simulation import Problem, Simulation
from onesim.visualization import plots, theme

theme.set()

# ## Geometry and mesh
#
# `load` returns each part, `section` its mid-plane cross-section. The resolved meshes follow the
# wall with elements of half its thickness; the thin model needs only the circle of the mid-line,
# with elements of 0.6 mm around the tube.

name = "dielectric_shell_field_shielding"
mid = lambda part: load(f"{name}{part}.step").section((0, 0, 1), origin=(0, 0, 0.0025))
gap = mid("")
edges = gap.boundaries
radius, walls = 0.005, (100, 250, 500, 1000)
meshes = {}
for micrometres in walls:
    thickness = 1e-6 * micrometres
    meshes[micrometres, "resolved"] = TriangularMesher(
        target_size=0.004,
        embedded_regions=(
            mid(f"_core_{micrometres}").named("core"),
            mid(f"_wall_{micrometres}").named("wall"),
        ),
        region_sizes={"wall": thickness / 2, "core": 0.0008},
    ).generate(gap)
    meshes[micrometres, "thin layer"] = TriangularMesher(
        target_size=0.004,
        embedded_regions=(mid(f"_midline_{micrometres}").named("core"),),
        region_sizes={"core": 0.0006},
    ).generate(gap)

fig = plots.figure(1, 3, size=(18, 6))
plots.geometry(
    [
        load(f"{name}.step").named("air between the plates"),
        load(f"{name}_wall_1000.step").named("tube wall, 1 mm"),
    ],
    labels=False,
    camera=plots.Camera(elevation=55, azimuth=-70),
    title="Capacitor gap with the dielectric tube",
    ax=fig[0],
)
plots.mesh(
    meshes[250, "resolved"],
    groups=("all",),
    legend=False,
    title=f"Resolved 0.25 mm wall: {meshes[250, 'resolved'].cell_count} triangles",
    ax=fig[1],
)
plots.mesh(
    meshes[250, "thin layer"],
    groups=("all",),
    legend=False,
    title=f"Thin dielectric layer: {meshes[250, 'thin layer'].cell_count} triangles",
    ax=fig[2],
)
plots.show()

# ## Models
#
# `regionwise` gives the wall of the resolved model its permittivity; `ThinDielectricLayer` acts on
# the faces between the two regions of the thin mesh, which `interface` returns.

epsilon0, er = 8.854187817e-12, 20.0
numerics = Numerics(
    spatial=FiniteElement(element=Lagrange(order=2)), linear_solver=SparseDirect()
)
models, results = {}, {}
for (micrometres, kind), mesh in meshes.items():
    law = (
        regionwise({"wall": er * epsilon0}, default=epsilon0, unit="F/m")
        if kind == "resolved"
        else regionwise((), default=epsilon0, unit="F/m")
    )
    model = PoissonEquation(domain=gap.domain(), permittivity=law)
    layer = (
        (
            ThinDielectricLayer(
                physics=model,
                boundary=interface(mesh, "background_core"),
                thickness=1e-6 * micrometres,
                permittivity=er * epsilon0,
            ),
        )
        if kind != "resolved"
        else ()
    )
    problem = Problem(
        name=f"Capacitor with a tube, {kind}",
        geometry=gap,
        physics=(model,),
        boundary_conditions=(
            FixedPotential(boundary=edges.terminal, physics=model, value=1.0),
            FixedPotential(boundary=edges.ground, physics=model, value=0.0),
            ZeroNormalElectricDisplacement(boundary=edges.insulated, physics=model),
        )
        + layer,
    )
    models[micrometres, kind] = model
    results[micrometres, kind] = Simulation(
        problem=problem, mesh=mesh, numerics=numerics
    ).solve_stationary()

# ## Results
#
# The field in the centre of the tube against the coated-cylinder formula, and the capacitance the
# tube adds to the empty capacitor ($\varepsilon_0\,w/h=8.854$ pF/m per metre of depth), from the
# charge on the upper plate.

exact = (
    lambda d: 4 * er / ((1 + er) ** 2 - (er - 1) ** 2 * (radius - d) ** 2 / radius**2)
)
E0, empty = 1.0 / gap.size[1], epsilon0 * gap.size[0] / gap.size[1]
field = {
    key: -result.field(models[key].electric_field).evaluate(np.array([[0.0, 0.0]]))[
        0, 1
    ]
    / E0
    for key, result in results.items()
}
added = {
    key: result.field(models[key].potential).reaction(edges.terminal) - empty
    for key, result in results.items()
}
print(
    "wall [mm]   d/b    E_in/E_0 exact   resolved   thin layer   thin vs resolved   added C' resolved [fF/m]   thin layer [fF/m]"
)
for micrometres in walls:
    a, b = field[micrometres, "resolved"], field[micrometres, "thin layer"]
    print(
        f"{micrometres / 1e3:9.2f} {micrometres / 5e3:6.2f} {exact(1e-6 * micrometres):16.4f} {a:10.4f} {b:12.4f} {100 * (b / a - 1):+16.1f} % "
        f"{1e15 * added[micrometres, 'resolved']:26.2f} {1e15 * added[micrometres, 'thin layer']:19.2f}"
    )

# For a wall of a fiftieth of the radius the thin layer gives the shielding of the resolved wall
# within 2 % on a fraction of the elements; at a fifth of the radius it shields about 20 % too much.
# The deviation falls in proportion to $d/b$, as expected of a first-order thin-layer model.
#
# ## Figure
#
# The field strength around the 0.25 mm wall in both models, and the field along the vertical line
# from the centre of the tube upward for the 0.25 mm and the 1 mm wall.

fig = plots.figure(1, 3, size=(21, 6))
for panel, kind in enumerate(("resolved", "thin layer")):
    plots.surface(
        results[250, kind].field(models[250, kind].electric_field),
        component=lambda E, position: np.linalg.norm(E, axis=1),
        limits=(0, 25),
        contours=11,
        subdivisions=2,
        xlimits=(-0.012, 0.012),
        ylimits=(-0.012, 0.012),
        xlabel="x [m]",
        ylabel="y [m]",
        label="|E| [V/m]",
        title=f"Field strength, {kind}, 0.25 mm wall",
        ax=fig[panel],
    )
y = np.linspace(0.0, 0.012, 601)
line = np.column_stack((np.zeros_like(y), y))
marks = np.column_stack((np.zeros(40), np.linspace(0.00015, 0.01185, 40)))
plots.line(
    points={
        f"thin layer, d = {m / 1e3:g} mm": (
            1e3 * marks[:, 1],
            -results[m, "thin layer"]
            .field(models[m, "thin layer"].electric_field)
            .evaluate(marks)[:, 1],
        )
        for m in (250, 1000)
    },
    reference={
        f"resolved, d = {m / 1e3:g} mm": (
            1e3 * y,
            -results[m, "resolved"]
            .field(models[m, "resolved"].electric_field)
            .evaluate(line)[:, 1],
        )
        for m in (250, 1000)
    },
    vlines=[1e3 * radius],
    ylimits=(0, 24),
    xlabel="y [mm]",
    ylabel="E_y [V/m]",
    title="Field along x = 0, from the centre upward",
    legend="lower right",
    ax=fig[2],
)
plots.show()

# ## Going further
#
# Change the permittivity of the wall, or give the layer a permittivity that varies along the
# circle (a callable of the position) to model a coating of uneven quality.