"""OneSimulation example: cyclic voltammetry at a planar macroelectrode.
Requires the installed, activated OneSimulation runtime.

The potential of a large planar electrode is swept linearly up and back while a one-electron redox
couple diffuses to and from its surface. The electrode reaction follows Butler-Volmer kinetics as a
nonlinear surface reaction of the species transport. The peak current is checked against the
Randles-Sevcik equation and the peak separation against Nicholson's working curve for slow kinetics.
"""

# # Cyclic voltammetry at a planar macroelectrode
#
# Cyclic voltammetry sweeps the potential $E$ of a working electrode linearly with the scan rate
# $v$ to a switching potential and back, and records the current. For a redox couple
# $\mathrm{R}\rightleftharpoons\mathrm{O}+e^-$ the shape of the voltammogram reveals the diffusion
# coefficient, the formal potential $E^0$ and the rate of electron transfer. Far from the edges of
# a large electrode the transport is one-dimensional diffusion normal to its surface,
#
# $$\frac{\partial c_i}{\partial t}=D\,\frac{\partial^2 c_i}{\partial x^2},\qquad i=\mathrm O,\mathrm R,$$
#
# and at the electrode the oxidation rate follows Butler-Volmer kinetics with the standard rate
# constant $k^0$ and the transfer coefficient $\alpha$,
#
# $$r=k^0\Big[c_\mathrm R\,e^{(1-\alpha)f(E-E^0)}-c_\mathrm O\,e^{-\alpha f(E-E^0)}\Big],\qquad
#   f=\frac{F}{RT},\qquad i=F\,r .$$
#
# | boundary | O | R |
# |---|---|---|
# | electrode $x=0$ | produced at the rate $r$ | consumed at the rate $r$ |
# | bulk $x=L$ | $c_\mathrm O=0$ | $c_\mathrm R=c^\infty$ |
#
# **Setup.** 1 mM of the reduced form, $D=10^{-9}$ m²/s for both species, $\alpha=0.5$, 25 °C;
# the potential runs from $E^0-0.3$ V to $E^0+0.3$ V and back at $v=0.1$ V/s.
#
# **Reference.** For fast electron transfer the peak current density is given by the
# Randles-Sevcik equation, $i_p=0.4463\,F c^\infty\sqrt{fvD}$, and the anodic and cathodic peaks
# lie $2.22\,RT/F=57$ mV apart (A.J. Bard, L.R. Faulkner, *Electrochemical Methods*, 2nd ed.,
# Wiley 2001, §6.2). For slower kinetics the separation grows with the dimensionless rate
# $\psi=k^0/\sqrt{\pi D f v}$ as tabulated by R.S. Nicholson, *Anal. Chem.* 37 (1965) 1351.

import numpy as np
from onesim.cad.d1 import Line
from onesim.meshing import NonuniformLineMesher
from onesim.numerics import Numerics
from onesim.numerics.fem import FiniteElement, Lagrange
from onesim.numerics.linear import SparseDirect
from onesim.numerics.nonlinear import Newton
from onesim.numerics.time import BDF, BackwardEuler
from onesim.physics.chemistry import (
    FixedConcentration,
    SpeciesTransport,
    SurfaceReaction,
    TransportSpecies,
)
from onesim.simulation import Problem, Simulation
from onesim.simulation.initial_conditions import InitialValue
from onesim.visualization import plots, theme

theme.set()

# ## Cell, potential programme and kinetics
#
# The diffusion layer grows to $\sqrt{D\,t}\approx0.1$ mm during the 12 s cycle; the cell is 1 mm
# deep, so the bulk boundary stays undisturbed. The potential is a triangle wave; the rate law is
# written once and serves both the boundary condition and the current.

faraday, gas_constant, temperature = 96485.33212, 8.314462618, 298.15
f = faraday / (gas_constant * temperature)
diffusivity, bulk, alpha, formal = 1.0e-9, 1.0, 0.5, 0.0
start, switch, scan_rate = formal - 0.3, formal + 0.3, 0.1
half_cycle = (switch - start) / scan_rate
potential = lambda t: start + scan_rate * (
    half_cycle - np.abs(np.asarray(t) - half_cycle)
)
depth = 1.0e-3
print(
    f"cycle {2 * half_cycle:.0f} s, diffusion length sqrt(D t) = {np.sqrt(diffusivity * 2 * half_cycle) * 1e6:.0f} µm, cell depth {depth * 1e3:.0f} mm"
)

# ## Mesh
#
# Eighty quadratic elements, graded geometrically from 0.1 µm at the electrode to 70 µm at the bulk.

line = Line(start=(0.0, 0.0, 0.0), end=(depth, 0.0, 0.0))
faces = depth * (np.geomspace(1.0, 701.0, 81) - 1.0) / 700.0
mesh = NonuniformLineMesher(faces=tuple(faces)).generate(line)
print(
    f"{mesh.cell_count} elements, first {faces[1] * 1e6:.2f} µm, last {(faces[-1] - faces[-2]) * 1e6:.0f} µm"
)

# ## Model and potential sweeps
#
# `SurfaceReaction` declares the Butler-Volmer rate on the electrode with the stoichiometry
# R → O; the species balance then carries the consumption of R and the production of O as the
# outward fluxes $-\nu_i r$. Five standard rate constants span the range from reversible
# ($\psi\approx90$) to strongly irreversible ($\psi=0.1$); each sweep runs with 1 mV steps of the
# second-order BDF method. The current density is $F$ times the flux of R into the electrode,
# `boundary_flux` of the recorded states; the initial state, which the kinetics have not yet
# relaxed, is left out.

psi_values = (90.4, 1.0, 0.5, 0.25, 0.1)
rate_constants = [
    psi * np.sqrt(np.pi * diffusivity * f * scan_rate) for psi in psi_values
]
voltammograms = {}
for psi, k0 in zip(psi_values, rate_constants):
    model = SpeciesTransport(
        domain=line.line,
        species=(
            TransportSpecies("O", diffusivity=diffusivity),
            TransportSpecies("R", diffusivity=diffusivity),
        ),
    )
    rate = lambda c, t: k0 * (
        c["R"] * np.exp((1 - alpha) * f * (potential(t) - formal))
        - c["O"] * np.exp(-alpha * f * (potential(t) - formal))
    )
    problem = Problem(
        name="Cyclic voltammetry",
        geometry=line,
        physics=(model,),
        boundary_conditions=(
            SurfaceReaction(
                physics=model,
                boundary=line.boundaries.start,
                rate=rate,
                stoichiometry={"R": -1, "O": 1},
            ),
            FixedConcentration(
                physics=model, boundary=line.boundaries.end, value={"O": 0.0, "R": bulk}
            ),
        ),
        initial_conditions=(
            InitialValue(model.field("O"), 0.0),
            InitialValue(model.field("R"), bulk),
        ),
    )
    result = Simulation(
        problem=problem,
        mesh=mesh,
        numerics=Numerics(
            spatial=FiniteElement(element=Lagrange(order=2)),
            nonlinear_solver=Newton(
                linear_solver=SparseDirect(),
                absolute_tolerance=1e-12,
                relative_tolerance=1e-10,
            ),
            time_integrator=BDF(order=2, startup=BackwardEuler()),
        ),
    ).run(start_time=0.0, end_time=2 * half_cycle, time_step=1e-3 / scan_rate)
    reduced = result.field(model.field("R"))
    times = np.asarray(reduced.times)[1:]
    voltammograms[psi] = (
        potential(times),
        faraday
        * np.array(
            [reduced.boundary_flux(line.boundaries.start, time=t) for t in times]
        ),
        times,
    )

# ## Comparison with the references
#
# Peak currents and potentials of the forward (anodic) and reverse (cathodic) sweeps. The
# reversible separation for a switching potential 300 mV beyond $E^0$ is 57.8 mV (Bard and
# Faulkner, Table 6.2.1); Nicholson's values hold to about 1 mV for the switching potential used here.

randles_sevcik = 0.4463 * faraday * bulk * np.sqrt(f * scan_rate * diffusivity)
reference = {90.4: 57.8, 1.0: 84.0, 0.5: 105.0, 0.25: 141.0, 0.1: 212.0}
peaks = {
    psi: (
        np.argmax(np.where(t <= half_cycle, i, -np.inf)),
        np.argmin(np.where(t > half_cycle, i, np.inf)),
    )
    for psi, (E, i, t) in voltammograms.items()
}
separations = {
    psi: (voltammograms[psi][0][a] - voltammograms[psi][0][c]) * 1e3
    for psi, (a, c) in peaks.items()
}
print(f"Randles-Sevcik peak current density: {randles_sevcik:.4f} A/m²")
print(
    f"{'psi':>6s} {'k0 [m/s]':>10s} {'i_pa [A/m²]':>12s} {'i_pa/i_RS':>10s} {'E_pa [mV]':>10s} {'E_pc [mV]':>10s} {'dEp [mV]':>9s} {'reference':>10s}"
)
for (psi, (a, c)), k0 in zip(peaks.items(), rate_constants):
    E, i, t = voltammograms[psi]
    print(
        f"{psi:6.2f} {k0:10.2e} {i[a]:12.4f} {i[a] / randles_sevcik:10.4f} {(E[a] - formal) * 1e3:10.1f} "
        f"{(E[c] - formal) * 1e3:10.1f} {separations[psi]:9.1f} {reference[psi]:10.1f}"
    )
E, i, t = voltammograms[90.4]
a = peaks[90.4][0]
half_peak = E[np.argmin(np.abs(i[:a] - 0.5 * i[a]))]
print(
    f"reversible wave: E_pa - E_p/2 = {(E[a] - half_peak) * 1e3:.1f} mV (theory 2.20 RT/F = {2.20e3 / f:.1f} mV), "
    f"E_pa - E0 = {(E[a] - formal) * 1e3:.1f} mV (theory 1.109 RT/F = {1.109e3 / f:.1f} mV)"
)

# ## Figure
#
# The voltammograms for the five rate constants, and the peak separation against the reference
# values.

fig = plots.figure(1, 2, size=(16, 6))
plots.line(
    y={
        f"ψ = {psi:g}": ((E - formal) * 1e3, i)
        for psi, (E, i, t) in voltammograms.items()
    },
    hlines={"Randles-Sevcik": randles_sevcik},
    xlabel="E - E⁰ [mV]",
    ylabel="current density i [A/m²]",
    title="Cyclic voltammograms at 0.1 V/s",
    legend="upper left",
    ax=fig[0],
)
plots.line(
    points={"OneSimulation": (list(separations), list(separations.values()))},
    reference={
        "Nicholson (1965), reversible limit": (
            list(reference),
            list(reference.values()),
        )
    },
    scale="logx",
    xlabel="kinetic parameter ψ = k⁰/√(πDfv)",
    ylabel="peak separation ΔE_p [mV]",
    title="Peak separation",
    legend="upper right",
    ax=fig[1],
)
plots.show()

# ## Going further
#
# Vary the scan rate at a fixed $k^0$: the peak current grows with $\sqrt v$ while the peaks drift
# apart, the classical way to measure $k^0$. An unequal transfer coefficient makes the wave
# asymmetric; a homogeneous follow-up reaction of O (`reactions=` in `SpeciesTransport`) removes
# the reverse peak (EC mechanism).